YZT48B21
YZT48B21 is in the certified data.
Its certified full-speed heating output at 5°F is 19,000–27,000 Btu/h5.57–7.91 kW, 40–57% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
York · central heat pump
YZT48B21 is in the certified data as of Sep 19, 2026. YZT48B21 changed its certified SEER2 on 2 pairings from 17.0 to 16.0 in the certified data between November 2024 and February 2025.
- 48,000 Btu (4-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
47,00013.77NR
No 47°F rating for this pairing.
32,2009.44NR at 17°F
26,2007.68NR at 5°F
Btu/hkW, certified
2.32NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 47,000 Btu/h13.77 kW of heat at 47°F, 32,200 Btu/h9.44 kW at 17°F, and 26,200 Btu/h7.68 kW at 5°F, 56% of its 47°F rating. It delivers 46,000 Btu/h13.48 kW of cooling at 95°F. At 5°F that is 10,300 Btu/h3.02 kW short of the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 28,000 Btu/h8.21 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210279420 · listed by York · certified Jul 7, 2026 · 2 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 26,2007.68 kW | −28% | 2.32 | |
| 17°Fone compressor speed | 32,2009.44 kW | −8% | NR | |
| 47°Fone compressor speed | 47,00013.77 kW | −2% | NR | |
| 95°Fcooling, full load | 46,00013.48 kW | — | NR |
EER2 12.0 in that test. SEER2 16.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.31kW
- Electrical input in the 95°F cooling test
- 3.83kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 26,200 Btu/h7.68 kWNR
- This unit at 5°F median across its pairings
- 26,200 Btu/h7.68 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 26% of them, at number 302 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- 4SHP18LX160PAirEase and Armstrong Air · 26,600 Btu/h
- RD17AZ48AJ3NFriedrich, Rheem + 3 more · 26,400 Btu/h
- HC19B4821Coleman · 26,200 Btu/h
- HRG1860S1PCentury and Comfort-Aire · 26,000 Btu/h
- YH548E2S11York · 26,000 Btu/h
- ML17XP1-048-230ALennox · 25,400 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YZT48B21
18 pairings · 18 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 47,000 Btu/h13.77 kWNR | 47,000–48,000 Btu/h13.77–14.07 kW |
| Heat output at 17°F full speed | 32,200 Btu/h9.44 kWNR | 31,600–33,000 Btu/h9.26–9.67 kW |
| Heat output at 5°F full speed | 26,200 Btu/h7.68 kWNR | 19,000–27,000 Btu/h5.57–7.91 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 56%NR | |
| COP at 5°F full speed | 2.32NR | 1.80–2.32 |
| HSPF2 Region IV | 8.1NR | 8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 46,000 Btu/h13.48 kWNR | 45,500–47,500 Btu/h13.33–13.92 kW |
| EER2 at 95°F | 12.0NR | 11.7–12.5 |
| SEER2 cooling season | 16.0NR | 16.0–17.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | XAFD60HBCN1 | 5 indoor units |
| Furnace | TM8Y120C20MP11 | 5 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YZT48B21 | |
Pairings, by indoor-unit class
5 indoor units · 18 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 4 indoor units
-
XAHC60HBCN1 (the pairing on screen) brand not stated 25,600 Btu/h7.50 kWat 5°F, full speed
-
XAFC60HBCN1 (the pairing on screen) brand not stated 25,800 Btu/h7.56 kWat 5°F, full speed
-
XAFD60HBCN1 (the pairing on screen) brand not stated 26,400 Btu/h7.74 kWat 5°F, full speed
-
XAHD60HBCN1 (the pairing on screen) brand not stated 26,600 Btu/h7.80 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| XAHC60HBCN1 (the pairing on screen) | — | 25,6007.50 | 48,00014.07 | 46,00013.48 | 53% | 2.24 | NC | 5 |
| XAFC60HBCN1 (the pairing on screen) | — | 25,8007.56 | 47,50013.92 | 46,75013.70 | 54% | 2.22 | NC | 4 |
| XAFD60HBCN1 (the pairing on screen) | — | 26,4007.74 | 47,00013.77 | 46,00013.48 | 56% | 2.30 | NC | 4 |
| XAHD60HBCN1 (the pairing on screen) | — | 26,6007.80 | 48,00014.07 | 46,00013.48 | 55% | 2.27 | NC | 4 |
Air handler · 1 indoor unit
-
JHETD60HBCS2N1 (the pairing on screen) brand not stated 19,000 Btu/h5.57 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| JHETD60HBCS2N1 (the pairing on screen) | — | 19,0005.57 | 47,00013.77 | 46,50013.63 | 40% | 1.80 | NC | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- YZT48B21 changed its certified SEER2 on 2 pairings from 17.0 to 16.0 in the certified data between November 2024 and February 2025.
- YZT48B21 changed its certified HSPF2 on 5 pairings from 8.1 to 7.8 in the certified data between November 2024 and February 2025.
- YZT48B21 changed its certified cooling capacity at 95°F on 5 pairings in the certified data between November 2024 and February 2025. The new figure is higher on 4 and lower on 1.
- YZT48B21 changed its certified heat output at 47°F on 5 pairings in the certified data between November 2024 and February 2025. The new figure is lower on all 5.
- YZT48B21 changed its certified heat output at 17°F on 5 pairings in the certified data between November 2024 and February 2025. The new figure is higher on 2 and lower on 3.
- YZT48B21 was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 7, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read