Heat Pump List

Tools

5TWR5024A1

5TWR5024A1 is in the certified data.

Its certified full-speed heating output at 5°F is 10,900–11,400 Btu/h, 50–52% of its 47°F rating, depending on the pairing.

Trane · central heat pump

All 104 certified Trane models

5TWR5024A1 is in the certified data as of Sep 19, 2026.

30 certified pairings with 24 different figures. See all

Certified heating and cooling

Heating at 47°F

21,800

14,500 at 17°F

11,200 at 5°F

Btu/h, certified

2.10 COP at 5°F

Cooling at 95°F

23,400

Btu/h, certified

EER2 12.0 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for 5TWR5024A1, by outdoor temperature Heating: 11,200 Btu/h at 5°F, 14,500 Btu/h at 17°F, 21,800 Btu/h at 47°F. Cooling: 23,400 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 11,200 5°F 14,500 17°F 21,800 47°F 23,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 21,800 Btu/h of heat at 47°F, 14,500 Btu/h at 17°F, and 11,200 Btu/h at 5°F, 51% of its 47°F rating. It delivers 23,400 Btu/h of cooling at 95°F. At 5°F that is 7,800 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 13,900 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214078325 · listed by Trane · certified Jun 3, 2026 · 1 pairing carries these values

Rebates where you live

Meets the recorded equipment thresholds of 29 programs in 18 states, provinces, or territories:California (2), Colorado (1), Delaware (1), Idaho (1), Kansas (1), Maryland (3), Michigan (2), Minnesota (2), Mississippi (1), Nevada (1), New Jersey (4), North Carolina (1), Oregon (2), Pennsylvania (3), South Carolina (1), Texas (3), Utah (1), Newfoundland and Labrador (1).

All 29 programs by state and province

California

Colorado

Delaware

Idaho

Kansas

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Jersey

North Carolina

Oregon

Pennsylvania

South Carolina

Texas

Utah

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 11,2003.28 kW −41% 2.10
17°Fone compressor speed 14,5004.25 kW −24% NR
47°Fone compressor speed 21,8006.39 kW −9% NR
95°Fcooling, full load 23,4006.86 kW — NR

EER2 12.0 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.56kW
Electrical input in the 95°F cooling test
1.95kW
Seasonal average heating COP
2.37

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
11,200 Btu/h
This unit at 5°F median across its pairings
11,200 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 12% of them, at number 500 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 24,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 473rd of 565 (tied); HSPF2, 498th of 578 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • GZV9SA241CA: The same 22,000 Btu/h rating at 47°F; 22,000 Btu/h at 5°F (this model: 11,200).
  • YH1824GHFD18R2: The same 22,000 Btu/h rating at 47°F; 16,900 Btu/h at 5°F (this model: 11,200).
  • MOX430U-22HFN1-MR0: The same 22,000 Btu/h rating at 47°F; 16,000 Btu/h at 5°F (this model: 11,200).

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 11,200 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42270–470
MildTypical16–26430–700
MildTight, well insulated10–18620–1,120
ColdDrafty, little insulation28–52220–400
ColdTypical18–30370–620
ColdTight, well insulated12–22510–930
Very coldDrafty, little insulation32–58190–350
Very coldTypical22–38290–510
Very coldTight, well insulated16–28400–700

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for 5TWR5024A1

30 pairings · 30 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for 5TWR5024A1
This pairingAll pairings
Heating
Heat output at 47°F one speed 21,800 Btu/h 21,000–22,800 Btu/h
Heat output at 17°F full speed 14,500 Btu/h 14,000–14,900 Btu/h
Heat output at 5°F full speed 11,200 Btu/h 10,900–11,400 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 51%
COP at 5°F full speed 2.10 2.00–2.20
HSPF2 Region IV 8.1 7.8–8.1
Cooling
Cooling capacity at 95°F full-load test 23,400 Btu/h 22,800–25,000 Btu/h
EER2 at 95°F 12.0 12.0
SEER2 cooling season 15.2 15.2–16.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Single stage
Indoor unit 5TXCB004AS3+TSTAT 14 indoor units
FurnaceS9X2B080U4PSB 16 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On some pairings
Where it is sold United States US and Canada
Model string as certified 5TWR5024A1

Across 30 certified pairings with 14 indoor models: heat at 5°F 10,900 Btu/h with 5TXCB006AS3+TSTAT to 11,400 Btu/h with 5PX*B006AS3+TSTAT; HSPF2 7.8 with 5TEM4B02AC21+TDR+TSTAT to 8.1 with 5TAMXD05AV41+TSTAT; SEER2 15.2 with 5TEM4B02AC21+TDR+TSTAT to 16.5 with 5PX*B006AS3+TSTAT. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

14 indoor units · 30 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 3 indoor units

  1. 5TXCB006AS3+TSTAT brand not stated 11,300 Btu/hat 5°F, full speed

    11 pairings, 11 with a furnace · 47°F 22,000 Btu/h · 95°F cooling 24,400 Btu/h · Cold output 51% · COP 2.10

  2. 5TXCB004AS3+TSTAT (the pairing on screen) brand not stated 11,100 Btu/hat 5°F, full speed

    5 pairings, 5 with a furnace · 47°F 21,800 Btu/h · 95°F cooling 23,200 Btu/h · Cold output 51% · COP 2.10

  3. 5PX*B006AS3+TSTAT brand not stated 11,400 Btu/hat 5°F, full speed

    3 pairings, 3 with a furnace · 47°F 22,000 Btu/h · 95°F cooling 25,000 Btu/h · Cold output 52% · COP 2.10

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
5TXCB006AS3+TSTAT — 11,300 22,000 24,400 51% 2.10 NC 11
5TXCB004AS3+TSTAT (the pairing on screen) — 11,100 21,800 23,200 51% 2.10 NC 5
5PX*B006AS3+TSTAT — 11,400 22,000 25,000 52% 2.10 NC 3

Air handler · 7 indoor units

  1. 5TAMXD05AV41+TSTAT brand not stated 11,100 Btu/hat 5°F, full speed

    1 pairing · 47°F 22,000 Btu/h · 95°F cooling 24,600 Btu/h · Cold output 50% · COP 2.10

  2. 5TEM4B02AC21+TDR+TSTAT brand not stated 11,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 22,600 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 50% · COP 2.10

  3. 5TEM4B03AC31+TDR+TSTAT brand not stated 11,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 22,800 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 50% · COP 2.10

  4. 5TEM4B04AC31+TDR+TSTAT brand not stated 11,300 Btu/hat 5°F, full speed

    1 pairing · 47°F 22,200 Btu/h · 95°F cooling 24,400 Btu/h · Cold output 51% · COP 2.10

  5. 5TEM4D04AC31+TDR+TSTAT brand not stated 11,100 Btu/hat 5°F, full speed

    1 pairing · 47°F 22,000 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 50% · COP 2.10

  6. 5TEMCB02AV21+TDR+TSTAT brand not stated 11,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 22,600 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 50% · COP 2.10

  7. 5TEMCB03AV31+TDR+TSTAT brand not stated 11,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 22,600 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 50% · COP 2.10

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
5TAMXD05AV41+TSTAT — 11,100 22,000 24,600 50% 2.10 NC 1
5TEM4B02AC21+TDR+TSTAT — 11,200 22,600 23,600 50% 2.10 NC 1
5TEM4B03AC31+TDR+TSTAT — 11,400 22,800 24,000 50% 2.10 NC 1
5TEM4B04AC31+TDR+TSTAT — 11,300 22,200 24,400 51% 2.10 NC 1
5TEM4D04AC31+TDR+TSTAT — 11,100 22,000 24,000 50% 2.10 NC 1
5TEMCB02AV21+TDR+TSTAT — 11,200 22,600 23,800 50% 2.10 NC 1
5TEMCB03AV31+TDR+TSTAT — 11,200 22,600 23,800 50% 2.10 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 14 indoor units All 30 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Other model numbers with identical certified values

2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

History and definitions

Other 15 Single-Stage Heat Pump models by nominal cooling size: 5TWR5018A1 (18,000 Btu), 5TWR5030A1 (30,000 Btu), 5TWR5036A1 (36,000 Btu), 5TWR5042A1 (42,000 Btu), 5TWR5048A1 (42,000 Btu), 5TWR5060A1 (54,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Jun 3, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “5TWR5024A1 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/5twr5024a1