A5HP5024A1

A5HP5024A1 is in the certified data.

Its certified full-speed heating output at 5°F is 10,600–11,800 Btu/h, 50–53% of its 47°F rating, depending on the pairing.

Ameristar and RunTru · central heat pump

A5HP5024A1 is in the certified data as of Sep 19, 2026.

72 certified pairings with 27 different figures. See all

Certified heating and cooling

Heating at 47°F

21,400

14,600 at 17°F

11,200 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

22,800

Btu/h, certified

EER2 12.0 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for A5HP5024A1, by outdoor temperature Heating: 11,200 Btu/h at 5°F, 14,600 Btu/h at 17°F, 21,400 Btu/h at 47°F. Cooling: 22,800 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 11,200 5°F 14,600 17°F 21,400 47°F 22,800 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 21,400 Btu/h of heat at 47°F, 14,600 Btu/h at 17°F, and 11,200 Btu/h at 5°F, 52% of its 47°F rating. It delivers 22,800 Btu/h of cooling at 95°F. At 5°F that is 7,800 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 13,300 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214296232 · listed by RunTru · certified Apr 9, 2025 · 4 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 11,2003.28 kW −41% 2.00
17°Fone compressor speed 14,6004.28 kW −24% NR
47°Fone compressor speed 21,4006.27 kW −11% NR
95°Fcooling, full load 22,8006.68 kW — NR

EER2 12.0 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.64kW
Electrical input in the 95°F cooling test
1.90kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
11,200 Btu/h
This unit at 5°F median across its pairings
11,200 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 12% of them, at number 500 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for A5HP5024A1

72 pairings · 72 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for A5HP5024A1
This pairingAll pairings
Heating
Heat output at 47°F one speed 21,400 Btu/h 20,600–23,000 Btu/h
Heat output at 17°F full speed 14,600 Btu/h 13,700–15,300 Btu/h
Heat output at 5°F full speed 11,200 Btu/h 10,600–11,800 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 52%
COP at 5°F full speed 2.00 1.90–2.10
HSPF2 Region IV 7.8 7.8–8.1
Cooling
Cooling capacity at 95°F full-load test 22,800 Btu/h 21,200–24,400 Btu/h
EER2 at 95°F 12.0 11.7–12.0
SEER2 cooling season 15.2 15.2–16.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Single stage
Indoor unit 5TXCB004AS3+TSTAT 11 indoor units
FurnaceA801X040BM2TD 21 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On some pairings
Where it is sold United States US and Canada
Model string as certified A5HP5024A1

Pairings, by indoor-unit class

11 indoor units · 72 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 3 indoor units

  1. 5TXCB004AS3+TSTAT (the pairing on screen) brand not stated 11,200 Btu/hat 5°F, full speed

    38 pairings, 19 with a furnace · 47°F 21,600 Btu/h · 95°F cooling 23,000 Btu/h · Cold output 52% · COP 2.00

  2. 5TXCB006AS3+TSTAT brand not stated 11,200 Btu/hat 5°F, full speed

    14 pairings, 7 with a furnace · 47°F 21,600 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 52% · COP 2.10

  3. 5PX*BD06AS3+TSTAT brand not stated 11,450 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 22,400 Btu/h · 95°F cooling 24,400 Btu/h · Cold output 51% · COP 2.05

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
5TXCB004AS3+TSTAT (the pairing on screen) — 11,200 21,600 23,000 52% 2.00 NC 38
5TXCB006AS3+TSTAT — 11,200 21,600 24,000 52% 2.10 NC 14
5PX*BD06AS3+TSTAT — 11,450 22,400 24,400 51% 2.05 NC 4

Air handler · 7 indoor units

  1. A5AHC002A1B3+TDR+TSTAT brand not stated 11,200 Btu/hat 5°F, full speed

    2 pairings · 47°F 22,600 Btu/h · 95°F cooling 23,400 Btu/h · Cold output 50% · COP 2.10

  2. A5AHC003A1B3+TDR+TSTAT brand not stated 11,400 Btu/hat 5°F, full speed

    2 pairings · 47°F 22,600 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 50% · COP 2.10

  3. A5AHC004A1B3+TDR+TSTAT brand not stated 11,400 Btu/hat 5°F, full speed

    2 pairings · 47°F 22,400 Btu/h · 95°F cooling 24,400 Btu/h · Cold output 51% · COP 2.10

  4. A5AHC004A1D3+TDR+TSTAT brand not stated 11,100 Btu/hat 5°F, full speed

    2 pairings · 47°F 21,800 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 51% · COP 2.10

  5. A5AHV002A1B3+TDR+TSTAT brand not stated 11,300 Btu/hat 5°F, full speed

    2 pairings · 47°F 22,400 Btu/h · 95°F cooling 23,000 Btu/h · Cold output 50% · COP 2.10

  6. A5AHV003A1B3+TDR+TSTAT brand not stated 11,800 Btu/hat 5°F, full speed

    2 pairings · 47°F 23,000 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 51% · COP 2.10

  7. A5AHV004A1D3+TDR+TSTAT brand not stated 11,600 Btu/hat 5°F, full speed

    2 pairings · 47°F 22,200 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 52% · COP 2.10

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
A5AHC002A1B3+TDR+TSTAT — 11,200 22,600 23,400 50% 2.10 NC 2
A5AHC003A1B3+TDR+TSTAT — 11,400 22,600 23,800 50% 2.10 NC 2
A5AHC004A1B3+TDR+TSTAT — 11,400 22,400 24,400 51% 2.10 NC 2
A5AHC004A1D3+TDR+TSTAT — 11,100 21,800 23,800 51% 2.10 NC 2
A5AHV002A1B3+TDR+TSTAT — 11,300 22,400 23,000 50% 2.10 NC 2
A5AHV003A1B3+TDR+TSTAT — 11,800 23,000 23,600 51% 2.10 NC 2
A5AHV004A1D3+TDR+TSTAT — 11,600 22,200 24,000 52% 2.10 NC 2

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 11 indoor units All 72 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Apr 9, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read