(C,H,T)5H6S60*K*AAA*
Kenmore · central heat pump
(C,H,T)5H6S60*K*AAA* is in the certified data as of Sep 19, 2026.
- 54,000 Btu (4.5-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
55,50016.27NR
No 47°F rating for this pairing.
35,40010.37NR at 17°F
28,4008.32NR at 5°F
Btu/hkW, certified
2.18NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 55,500 Btu/h16.27 kW of heat at 47°F, 35,400 Btu/h10.37 kW at 17°F, and 28,400 Btu/h8.32 kW at 5°F, 51% of its 47°F rating. It delivers 57,000 Btu/h16.71 kW of cooling at 95°F. At 5°F that is 11,600 Btu/h3.40 kW short of the example heating load of 40,000 Btu/h11.72 kW; at 95°F it is 37,000 Btu/h10.84 kW above the example cooling load of 20,000 Btu/h5.86 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h11.72 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h5.86 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214602009 · listed by Kenmore · certified Jun 29, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 28,4008.32 kW | −29% | 2.18 | |
| 17°Fone compressor speed | 35,40010.37 kW | −6% | NR | |
| 47°Fone compressor speed | 55,50016.27 kW | −1% | NR | |
| 95°Fcooling, full load | 57,00016.71 kW | — | NR |
EER2 12.5 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.82kW
- Electrical input in the 95°F cooling test
- 4.56kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 54,000 Btu heat pumps
4.5-ton central models
- This pairing at 5°F
- 28,400 Btu/h8.32 kWNR
- This unit at 5°F median across its pairings
- 28,400 Btu/h8.32 kW
- Median of 4.5-ton central models at 5°F
- 40,000 Btu/h11.72 kW
- Models in this group
- 343
This unit is above 10% of them, at number 307 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.
Closest models by heat at 5°F
- GLZS5BA6010AGoodman · 30,000 Btu/h
- GSZC706010AGoodman · 30,000 Btu/h
- GH5SAN560**AA*Bryant and Carrier · 28,600 Btu/h
- 5TWR5060A1Trane · 28,200 Btu/h
- 5TWX5060A1Trane · 28,200 Btu/h
- A5HP5060A1Ameristar and RunTru · 28,200 Btu/h
Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for (C,H,T)5H6S60*K*AAA*
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 55,500 Btu/h16.27 kWNR | 55,500 Btu/h16.27 kW |
| Heat output at 17°F full speed | 35,400 Btu/h10.37 kWNR | 35,400 Btu/h10.37 kW |
| Heat output at 5°F full speed | 28,400 Btu/h8.32 kWNR | 28,400 Btu/h8.32 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 51%NR | |
| COP at 5°F full speed | 2.18NR | 2.18 |
| HSPF2 Region IV | 7.8NR | 7.8 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 57,000 Btu/h16.71 kWNR | 57,000 Btu/h16.71 kW |
| EER2 at 95°F | 12.5NR | 12.5 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Single stage | |
| Indoor unit | FTMA5B60L0D* | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | (C,H,T)5H6S60*K*AAA* | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Air handler · 1 indoor unit
-
FTMA5B60L0D* (the pairing on screen) brand not stated 28,400 Btu/h8.32 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| FTMA5B60L0D* (the pairing on screen) | — | 28,4008.32 | 55,50016.27 | 57,00016.71 | 51% | 2.18 | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- (C,H,T)5H6S60*K*AAA* 1 pairing
Variants of the same model number
5 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- B5H6S60*K*AAA*Airquest · Arcoaire · Comfortmaker · Day & Night · Heil · Keeprite · Kenmore · Tempstar
- C5H6S60*K*AAA*Comfortmaker · Day & Night · Keeprite
- H5H6S60*K*AAA*Airquest · Arcoaire · Heil
- T5H6S60*K*AAA*Tempstar
4 of 5 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 29, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read