H5H6S60*K*AAA*

Airquest, Arcoaire + 1 more · central heat pump

H5H6S60*K*AAA* is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

55,500

35,400 at 17°F

28,400 at 5°F

Btu/h, certified

2.18 COP at 5°F

Cooling at 95°F

57,000

Btu/h, certified

EER2 12.5 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for H5H6S60*K*AAA*, by outdoor temperature Heating: 28,400 Btu/h at 5°F, 35,400 Btu/h at 17°F, 55,500 Btu/h at 47°F. Cooling: 57,000 Btu/h at 95°F. The bars start at zero. Median of 4.5-ton central models: 40,000 Btu/h at 5°F, 37,800 Btu/h at 17°F, 56,000 Btu/h at 47°F, 55,000 Btu/h at 95°F. 0 20,000 40,000 60,000 Btu/h 28,400 5°F 35,400 17°F 55,500 47°F 57,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 55,500 Btu/h of heat at 47°F, 35,400 Btu/h at 17°F, and 28,400 Btu/h at 5°F, 51% of its 47°F rating. It delivers 57,000 Btu/h of cooling at 95°F. At 5°F that is 11,600 Btu/h short of the example heating load of 40,000 Btu/h; at 95°F it is 37,000 Btu/h above the example cooling load of 20,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214602003 · listed by Heil · certified Jul 16, 2026 · 3 pairings on 3 certificates share these values

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 28,4008.32 kW −29% 2.18
17°Fone compressor speed 35,40010.37 kW −6% NR
47°Fone compressor speed 55,50016.27 kW −1% NR
95°Fcooling, full load 57,00016.71 kW — NR

EER2 12.5 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.82kW
Electrical input in the 95°F cooling test
4.56kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 54,000 Btu heat pumps

4.5-ton central models

This pairing at 5°F
28,400 Btu/h
This unit at 5°F median across its pairings
28,400 Btu/h
Median of 4.5-ton central models at 5°F
40,000 Btu/h
Models in this group
343

This unit is above 10% of them, at number 307 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for H5H6S60*K*AAA*

3 pairings · 3 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for H5H6S60*K*AAA*
This pairingAll pairings
Heating
Heat output at 47°F one speed 55,500 Btu/h 55,500 Btu/h
Heat output at 17°F full speed 35,400 Btu/h 35,400 Btu/h
Heat output at 5°F full speed 28,400 Btu/h 28,400 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 51%
COP at 5°F full speed 2.18 2.18
HSPF2 Region IV 7.8 7.8
Cooling
Cooling capacity at 95°F full-load test 57,000 Btu/h 57,000 Btu/h
EER2 at 95°F 12.5 12.5
SEER2 cooling season 15.2 15.2
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Single stage
Indoor unit FTMA5B60L0D* 1 indoor unit
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified H5H6S60*K*AAA*

Pairings, by indoor-unit class

1 indoor unit · 3 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 1 indoor unit

  1. FTMA5B60L0D* (the pairing on screen) brand not stated 28,400 Btu/hat 5°F, full speed

    3 pairings · 47°F 55,500 Btu/h · 95°F cooling 57,000 Btu/h · Cold output 51% · COP 2.18

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
FTMA5B60L0D* (the pairing on screen) — 28,400 55,500 57,000 51% 2.18 NC 3

The share is heat output at 5°F divided by the 47°F rating.

Showing 1 of 1 indoor unit

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

Variants of the same model number

5 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

4 of 5 shown.

Other model numbers with identical certified values

2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jul 16, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read