ARUM048GSS5
ARUM048GSS5 is in the certified data.
Its certified full-speed heating output at 5°F is 48,000 Btu/h14.07 kW, 79–86% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
LG · mini-split heat pump
ARUM048GSS5 is in the certified data as of Sep 19, 2026. ARUM048GSS5 changed its certified EER2 on AHRI certificate 205967236 from 12.2 to 13.0 in the certified data between March 2025 and May 2025.
- 48,000 Btu (4-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
56,00016.41NR
No 47°F rating for this pairing.
36,40010.67NR at 17°F
48,00014.07NR at 5°F
Btu/hkW, certified
1.83NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 56,000 Btu/h16.41 kW of heat at 47°F, 36,400 Btu/h10.67 kW at 17°F, and 48,000 Btu/h14.07 kW at 5°F, 86% of its 47°F rating. It delivers 48,000 Btu/h14.07 kW of cooling at 95°F. At 5°F that is 6,000 Btu/h1.76 kW above the example heating load of 42,000 Btu/h12.31 kW; at 95°F it is 27,000 Btu/h7.91 kW above the example cooling load of 21,000 Btu/h6.15 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,750 sq ft where winters reach 5°F: heating runs from 42,000 Btu/h12.31 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 21,000 Btu/h6.15 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 205967236 · listed by LG · certified Jan 30, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 11 programs in 7 states, provinces, or territories:British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 11 programs by state and province
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 48,00014.07 kW | +14% | 1.83 | |
| 17°Ffull speed | 36,40010.67 kW | −4% | NR | |
| 47°Fnormal speed | 56,00016.41 kW | +14% | NR | |
| 95°Fcooling, full load | 48,00014.07 kW | — | NR |
EER2 13.0 in that test. SEER2 17.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 7.69kW
- Electrical input in the 95°F cooling test
- 3.69kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton mini-split models
- This pairing at 5°F
- 48,000 Btu/h14.07 kWNR
- This unit at 5°F median across its pairings
- 48,000 Btu/h14.07 kW
- Median of 4-ton mini-split models at 5°F
- 42,000 Btu/h12.31 kW
- Models in this group
- 321
This unit is above 84% of them, at number 50 of 321 by heat at 5°F. The middle half of the group runs 37,000 to 47,500 Btu/h.
Among 48,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 164th of 321; HSPF2, 130th of 321 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- LMU543HV: 58,000 Btu/h at 47°F (this model: 58,500); 35,800 Btu/h at 5°F (this model: 48,000).
- KUMXB541A: 58,000 Btu/h at 47°F (this model: 58,500); 40,000 Btu/h at 5°F (this model: 48,000).
- SUZ-AK48NLHZ: 60,000 Btu/h at 47°F (this model: 58,500); HSPF2 8.5 (this model: 10.15).
Closest models by heat at 5°F
- MLB048S4S-2PLennox · 49,000 Btu/h
- RUZ-AK48NLHZMitsubishi Electric · 48,500 Btu/h
- 500006193Convectair · 48,000 Btu/h
- AUW-48U3TH1Hisense · 48,000 Btu/h
- CH-NHPR48LCU-230VOC&H and Cooper&Hunter · 48,000 Btu/h
- CSZ48H424ZMOSea Breeze · 48,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 48,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 1,140–2,000 |
| Mild | Typical | 16–26 | 1,850–3,000 |
| Mild | Tight, well insulated | 10–18 | 2,670–4,800 |
| Cold | Drafty, little insulation | 28–52 | 920–1,710 |
| Cold | Typical | 18–30 | 1,600–2,670 |
| Cold | Tight, well insulated | 12–22 | 2,180–4,000 |
| Very cold | Drafty, little insulation | 32–58 | 830–1,500 |
| Very cold | Typical | 22–38 | 1,260–2,180 |
| Very cold | Tight, well insulated | 16–28 | 1,710–3,000 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for ARUM048GSS5
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 56,000 Btu/h16.41 kWNR | 56,000–61,000 Btu/h16.41–17.88 kW |
| Heat output at 17°F full speed | 36,400 Btu/h10.67 kWNR | 36,400–38,500 Btu/h10.67–11.28 kW |
| Heat output at 5°F full speed | 48,000 Btu/h14.07 kWNR | 48,000 Btu/h14.07 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 86%NR | |
| COP at 5°F full speed | 1.83NR | 1.83 |
| HSPF2 Region IV | 10.0NR | 10.0–10.3 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 48,000 Btu/h14.07 kWNR | 48,000 Btu/h14.07 kW |
| EER2 at 95°F | 13.0NR | 12.85–13.5 |
| SEER2 cooling season | 17.0NR | 17.0–23.3 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | Canada | Canada |
| Model string as certified | ARUM048GSS5 | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) LG 48,000 Btu/h14.07 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | LG | 48,00014.07 | 58,50017.14 | 48,00014.07 | 82% | 1.83 | Yes | 3 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- ARUM048GSS5 changed its certified EER2 on AHRI certificate 205967236 from 12.2 to 13.0 in the certified data between March 2025 and May 2025.
- ARUM048GSS5 was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 30, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read