DLCSRBH09AAK

DLCSRBH09AAK is in the certified data.

Its certified full-speed heating output at 5°F is 10,000–11,000 Btu/h, 88–110% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Airquest, Arcoaire + 12 more · mini-split heat pump

All 175 certified Airquest models · All 175 certified Arcoaire models · All 205 certified Bryant models · All 187 certified Carrier models · All 173 certified Comfortmaker models · All 177 certified Day & Night models · All 176 certified Heil models · All 175 certified Keeprite models · All 179 certified Kenmore models · All 96 certified LPS Legacy models · All 359 certified Midea models · All 108 certified Smart Comfort models · All 175 certified Tempstar models · All 62 certified Viessmann models

DLCSRBH09AAK is in the certified data as of Sep 19, 2026.

99 certified pairings with 6 different figures. See all

Certified heating and cooling

Heating at 47°F

12,000

9,500 at 17°F

10,600 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

9,000

Btu/h, certified

EER2 16.2 at 95°F

SEER2 28.1

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for DLCSRBH09AAK, by outdoor temperature Heating: 10,600 Btu/h at 5°F, 9,500 Btu/h at 17°F, 12,000 Btu/h at 47°F. Cooling: 9,000 Btu/h at 95°F. The bars start at zero. Median of 9,000 Btu mini-split models: 7,700 Btu/h at 5°F, 8,000 Btu/h at 17°F, 10,000 Btu/h at 47°F, 9,000 Btu/h at 95°F. 0 2,500 5,000 7,500 10,000 12,500 Btu/h 10,600 5°F 9,500 17°F 12,000 47°F 9,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 9,000 Btu mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 12,000 Btu/h of heat at 47°F, 9,500 Btu/h at 17°F, and 10,600 Btu/h at 5°F, 88% of its 47°F rating. It delivers 9,000 Btu/h of cooling at 95°F. At 5°F that is 3,100 Btu/h above the example heating load of 7,500 Btu/h; at 95°F it is 5,500 Btu/h above the example cooling load of 3,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 9,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 208447617 · listed by Arcoaire · certified Jun 13, 2026 · 24 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 59 programs in 35 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Colorado (2), Connecticut (1), Delaware (2), Idaho (2), Illinois (1), Kentucky (1), Maine (2), Maryland (3), Massachusetts (1), Michigan (2), Minnesota (2), Mississippi (2), Nevada (1), New Hampshire (2), New Jersey (7), New York (4), Oregon (2), Pennsylvania (4), Rhode Island (1), Tennessee (1), Texas (2), Utah (1), Vermont (3), Washington (2), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 59 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Delaware

Idaho

Illinois

Kentucky

Maine

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

Oregon

Pennsylvania

Rhode Island

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 9,000 Btu mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 10,6003.11 kW +38% 2.00
17°Ffull speed 9,5002.78 kW +19% NR
47°Fnormal speed 12,0003.52 kW +20% NR
95°Fcooling, full load 9,0002.64 kW — NR

EER2 16.2 in that test. SEER2 28.1 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.55kW
Electrical input in the 95°F cooling test
0.56kW
Seasonal average heating COP
3.37

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 9,000 Btu heat pumps

9,000 Btu mini-split models

This pairing at 5°F
10,600 Btu/h
This unit at 5°F median across its pairings
10,600 Btu/h
Median of 9,000 Btu mini-split models at 5°F
7,700 Btu/h
Models in this group
894

This unit is above 83% of them, at number 154 of 894 by heat at 5°F. The middle half of the group runs 7,000 to 9,500 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 9,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 187th of 894 (tied); HSPF2, 152nd of 909 (tied). Models without that figure are left out.

Similar ratings at 47°F

These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • KUSAF091F: The same 10,900 Btu/h rating at 47°F; 7,700 Btu/h at 5°F (this model: 10,600).
  • RXQ09ASBU: The same 10,900 Btu/h rating at 47°F; 7,600 Btu/h at 5°F (this model: 10,600).
  • MUZ-WR09NA: The same 10,900 Btu/h rating at 47°F; HSPF2 8.5 (this model: 11.6).

Closest models by heat at 5°F

Every 9,000 Btu unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 10,600 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42250–440
MildTypical16–26410–660
MildTight, well insulated10–18590–1,060
ColdDrafty, little insulation28–52200–380
ColdTypical18–30350–590
ColdTight, well insulated12–22480–880
Very coldDrafty, little insulation32–58180–330
Very coldTypical22–38280–480
Very coldTight, well insulated16–28380–660

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for DLCSRBH09AAK

99 pairings · 95 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for DLCSRBH09AAK
This pairingAll pairings
Heating
Heat output at 47°F normal speed 12,000 Btu/h 9,800–12,000 Btu/h
Heat output at 17°F full speed 9,500 Btu/h 8,600–10,100 Btu/h
Heat output at 5°F full speed 10,600 Btu/h 10,000–11,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 88%
COP at 5°F full speed 2.00 1.80–2.00
HSPF2 Region IV 11.5 10.0–12.4
Cooling
Cooling capacity at 95°F full-load test 9,000 Btu/h 9,000 Btu/h
EER2 at 95°F 16.2 13.0–16.2
SEER2 cooling season 28.1 20.2–28.1
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit DLFSHCH09XAK 8 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified DLCSRBH09AAK

Across 99 certified pairings with 8 indoor models: heat at 5°F 10,000 Btu/h with DLFSCAH09XAK to 11,000 Btu/h with DLFSHBH09XAK; HSPF2 10.0 with DLFSDAH09XHK to 12.4 with DLFCCAH09XAK; SEER2 20.2 with DLFSDAH09XAK to 28.1 with DHMAHBQ09XA3. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

8 indoor units · 99 certified pairings

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 8 indoor units

  1. DLFSHBH09XAK AIRQUEST 11,000 Btu/hat 5°F, full speed

    14 pairings · 47°F 12,000 Btu/h · 95°F cooling 9,000 Btu/h · Cold output 92% · COP 1.85

  2. DLFSDAH09XAK AIRQUEST 10,800 Btu/hat 5°F, full speed

    13 pairings · 47°F 10,000 Btu/h · 95°F cooling 9,000 Btu/h · Cold output 108% · COP 1.90

  3. DLFSHCH09XAK (the pairing on screen) AIRQUEST 10,600 Btu/hat 5°F, full speed

    13 pairings · 47°F 12,000 Btu/h · 95°F cooling 9,000 Btu/h · Cold output 88% · COP 2.00

  4. DLFCCAH09XAK AIRQUEST 10,500 Btu/hat 5°F, full speed

    12 pairings · 47°F 10,900 Btu/h · 95°F cooling 9,000 Btu/h · Cold output 96% · COP 1.80

  5. DLFSCAH09XAK AIRQUEST 10,000 Btu/hat 5°F, full speed

    12 pairings · 47°F 9,800 Btu/h · 95°F cooling 9,000 Btu/h · Cold output 102% · COP 1.80

  6. DLFSDAH09XHK AIRQUEST 10,800 Btu/hat 5°F, full speed

    12 pairings · 47°F 9,800 Btu/h · 95°F cooling 9,000 Btu/h · Cold output 110% · COP 1.90

  7. DLFSOAH09XAK AIRQUEST 10,500 Btu/hat 5°F, full speed

    12 pairings · 47°F 10,900 Btu/h · 95°F cooling 9,000 Btu/h · Cold output 96% · COP 1.80

  8. DHMAHBQ09XA3 AIRQUEST 10,600 Btu/hat 5°F, full speed

    11 pairings · 47°F 12,000 Btu/h · 95°F cooling 9,000 Btu/h · Cold output 88% · COP 2.00

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
DLFSHBH09XAK AIRQUEST 11,000 12,000 9,000 92% 1.85 Yes 14
DLFSDAH09XAK AIRQUEST 10,800 10,000 9,000 108% 1.90 Yes 13
DLFSHCH09XAK (the pairing on screen) AIRQUEST 10,600 12,000 9,000 88% 2.00 Yes 13
DLFCCAH09XAK AIRQUEST 10,500 10,900 9,000 96% 1.80 Yes 12
DLFSCAH09XAK AIRQUEST 10,000 9,800 9,000 102% 1.80 Yes 12
DLFSDAH09XHK AIRQUEST 10,800 9,800 9,000 110% 1.90 Yes 12
DLFSOAH09XAK AIRQUEST 10,500 10,900 9,000 96% 1.80 Yes 12
DHMAHBQ09XA3 AIRQUEST 10,600 12,000 9,000 88% 2.00 Yes 11

The share is heat output at 5°F divided by the 47°F rating.

Showing 8 of 8 indoor units

Sold as, and units with identical certified values

History and definitions

Other DLC Series models by nominal cooling size: DLCSRBH06AAK (6,000 Btu), DLCSRBH12AAJ (12,000 Btu), DLCSRBH12AAK (12,000 Btu), DLCSRBH18AAK (18,000 Btu), DLCURAH18ABK (18,000 Btu), DLCSRBH24AAK (24,000 Btu), DLCURAH24AAK (24,000 Btu), DLCURAH24ABK (24,000 Btu); more models from this brand.

Other DLC-series models by nominal cooling size: DLCSRBH06AAK (6,000 Btu), DLCPRBH09AAK (9,000 Btu), DLCPRBH12AAK (12,000 Btu), DLCSRBH12AAJ (12,000 Btu), DLCSRBH12AAK (12,000 Btu), DLCPRBH18AAK (18,000 Btu), DLCSRBH18AAK (18,000 Btu), DLCSRBH24AAK (24,000 Btu); more models from this brand.

Other DLC Series models by nominal cooling size: DLCSRBH06AAK (6,000 Btu), DLCSRBH12AAJ (12,000 Btu), DLCSRBH12AAK (12,000 Btu), DLCSRBH18AAK (18,000 Btu), DLCURAH18ABK (18,000 Btu), DLCSRBH24AAK (24,000 Btu), DLCURAH24AAK (24,000 Btu), DLCURAH24ABK (24,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Jun 13, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “DLCSRBH09AAK — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/dlcsrbh09aak