E4HL5060A1000A
E4HL5060A1000A is in the certified data.
Its certified full-speed heating output at 5°F is 33,400 Btu/h9.79 kW, 74% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Ameristar and RunTru · central heat pump
E4HL5060A1000A is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
45,00013.19NR
No 47°F rating for this pairing.
29,4008.62NR at 17°F
33,4009.79NR at 5°F
Btu/hkW, certified
1.75NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 45,000 Btu/h13.19 kW of heat at 47°F, 29,400 Btu/h8.62 kW at 17°F, and 33,400 Btu/h9.79 kW at 5°F, 74% of its 47°F rating. It delivers 47,500 Btu/h13.92 kW of cooling at 95°F. At 5°F that is 3,100 Btu/h0.91 kW short of the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 29,500 Btu/h8.65 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215402234 · listed by Ameristar · certified Aug 16, 2024 · 2 pairings on 2 certificates share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 33,4009.79 kW | −8% | 1.75 | |
| 17°Ffull speed | 29,4008.62 kW | −16% | NR | |
| 47°Fnormal speed | 45,00013.19 kW | −6% | NR | |
| 95°Fcooling, full load | 47,50013.92 kW | — | NR |
EER2 9.5 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.59kW
- Electrical input in the 95°F cooling test
- 5.00kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 33,400 Btu/h9.79 kWNR
- This unit at 5°F median across its pairings
- 33,400 Btu/h9.79 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 33% of them, at number 272 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- MO1AE-H48B-2AMidea · 33,600 Btu/h
- MOD30-48HFN10-M3FMDV · 33,600 Btu/h
- YDV60E2D11York · 33,600 Btu/h
- THH60HAI2NAF2U23TCL · 33,400 Btu/h
- A7CP21V48P-**AAC Pro, AirEase + 1 more · 33,200 Btu/h
- EL21KLV-048-230ALennox · 33,200 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for E4HL5060A1000A
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 45,000 Btu/h13.19 kWNR | 45,000 Btu/h13.19 kW |
| Heat output at 17°F full speed | 29,400 Btu/h8.62 kWNR | 29,400 Btu/h8.62 kW |
| Heat output at 5°F full speed | 33,400 Btu/h9.79 kWNR | 33,400 Btu/h9.79 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 74%NR | |
| COP at 5°F full speed | 1.75NR | 1.75 |
| HSPF2 Region IV | 8.1NR | 8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 47,500 Btu/h13.92 kWNR | 47,500 Btu/h13.92 kW |
| EER2 at 95°F | 9.5NR | 9.5 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | 4TXCD010DS3 | 1 indoor unit |
| Furnace | A801X120DM5SD | 1 furnace |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | E4HL5060A1000A | |
Pairings, by indoor-unit class
1 indoor unit · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 1 indoor unit
-
4TXCD010DS3 (the pairing on screen) brand not stated 33,400 Btu/h9.79 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 4TXCD010DS3 (the pairing on screen) | — | 33,4009.79 | 45,00013.19 | 47,50013.92 | 74% | 1.75 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- E4HL5060A1000A 2 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Aug 16, 2024
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read