FWP15AZ18AJ2N
Friedrich · central heat pump
FWP15AZ18AJ2N is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
17,1005.01NR
No 47°F rating for this pairing.
12,2003.58NR at 17°F
9,3002.73NR at 5°F
Btu/hkW, certified
2.20NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 17,100 Btu/h5.01 kW of heat at 47°F, 12,200 Btu/h3.58 kW at 17°F, and 9,300 Btu/h2.73 kW at 5°F, 54% of its 47°F rating. It delivers 17,100 Btu/h5.01 kW of cooling at 95°F. At 5°F that is 1,700 Btu/h0.50 kW short of the example heating load of 11,000 Btu/h3.22 kW; at 95°F it is 11,600 Btu/h3.40 kW above the example cooling load of 5,500 Btu/h1.61 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h3.22 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h1.61 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 213841765 · listed by Friedrich · certified Jun 3, 2026 · 10 pairings share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 9,3002.73 kW | −17% | 2.20 | |
| 17°Ffull speed | 12,2003.58 kW | −3% | NR | |
| 47°Fhigh stage | 17,1005.01 kW | −5% | NR | |
| 95°Fcooling, full load | 17,1005.01 kW | — | NR |
EER2 11.7 in that test. SEER2 16.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.24kW
- Electrical input in the 95°F cooling test
- 1.46kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton central models
- This pairing at 5°F
- 9,300 Btu/h2.73 kWNR
- This unit at 5°F median across its pairings
- 9,300 Btu/h2.73 kW
- Median of 1.5-ton central models at 5°F
- 11,200 Btu/h3.28 kW
- Models in this group
- 243
This unit is above 35% of them, at number 159 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.
Closest models by heat at 5°F
- MO1BE-H18B-2AMidea · 10,000 Btu/h
- MVP-18-HP-C-230A00-OMRCOOL · 10,000 Btu/h
- TZID18H520ZCSThermal Zone · 10,000 Btu/h
- MPP15AZ18AJ2NMainline · 9,300 Btu/h
- RP15AZ18AJ2NRheem and Ruud · 9,300 Btu/h
- TZP15AZ18AJ2NThermal Zone · 9,300 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for FWP15AZ18AJ2N
42 pairings · 42 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 17,100 Btu/h5.01 kWNR | 17,100 Btu/h5.01 kW |
| Heat output at 17°F full speed | 12,200 Btu/h3.58 kWNR | 11,000–12,300 Btu/h3.22–3.60 kW |
| Heat output at 5°F full speed | 9,300 Btu/h2.73 kWNR | 8,100–9,500 Btu/h2.37–2.78 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 54%NR | |
| COP at 5°F full speed | 2.20NR | 1.90–2.20 |
| HSPF2 Region IV | 8.1NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 17,100 Btu/h5.01 kWNR | 17,100 Btu/h5.01 kW |
| EER2 at 95°F | 11.7NR | 11.7 |
| SEER2 cooling season | 16.0NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | TCFZ2417STANM | 6 indoor units |
| Furnace | FR951V0403A17M4 | 19 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | FWP15AZ18AJ2N | |
Pairings, by indoor-unit class
6 indoor units · 42 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 2 indoor units
-
RCFZ2417STANM (the pairing on screen) brand not stated 9,300 Btu/h2.73 kWat 5°F, full speed
-
TCFZ2417STANM (the pairing on screen) brand not stated 9,300 Btu/h2.73 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| RCFZ2417STANM (the pairing on screen) | — | 9,3002.73 | 17,1005.01 | 17,1005.01 | 54% | 2.20 | NC | 19 |
| TCFZ2417STANM (the pairing on screen) | — | 9,3002.73 | 17,1005.01 | 17,1005.01 | 54% | 2.20 | NC | 19 |
Air handler · 4 indoor units
-
FRH2TZ2417STANN (the pairing on screen) brand not stated 9,200 Btu/h2.70 kWat 5°F, full speed
-
FRH2VZ2417STANN (the pairing on screen) brand not stated 9,200 Btu/h2.70 kWat 5°F, full speed
-
FRH3VZ2417STACN (the pairing on screen) brand not stated 8,100 Btu/h2.37 kWat 5°F, full speed
-
RF2TZ2421STANS (the pairing on screen) brand not stated 8,300 Btu/h2.43 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| FRH2TZ2417STANN (the pairing on screen) | — | 9,2002.70 | 17,1005.01 | 17,1005.01 | 54% | 2.10 | NC | 1 |
| FRH2VZ2417STANN (the pairing on screen) | — | 9,2002.70 | 17,1005.01 | 17,1005.01 | 54% | 2.20 | NC | 1 |
| FRH3VZ2417STACN (the pairing on screen) | — | 8,1002.37 | 17,1005.01 | 17,1005.01 | 47% | 2.00 | NC | 1 |
| RF2TZ2421STANS (the pairing on screen) | — | 8,3002.43 | 17,1005.01 | 17,1005.01 | 49% | 1.90 | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- FWP15AZ18AJ2N 42 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 3, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read