GS4M30HP230V1MO
GS4M30HP230V1MO is in the certified data.
Its certified full-speed heating output at 5°F is 26,000–27,000 Btu/h7.62–7.91 kW, 87–90% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Gree · mini-split heat pump
GS4M30HP230V1MO is in the certified data as of Sep 19, 2026.
- 30,000 Btu (2.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
30,0008.79NR
No 47°F rating for this pairing.
27,6008.09NR at 17°F
26,4007.74NR at 5°F
Btu/hkW, certified
1.81NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 30,000 Btu/h8.79 kW of heat at 47°F, 27,600 Btu/h8.09 kW at 17°F, and 26,400 Btu/h7.74 kW at 5°F, 88% of its 47°F rating. It delivers 28,400 Btu/h8.32 kW of cooling at 95°F. At 5°F that is 1,400 Btu/h0.41 kW above the example heating load of 25,000 Btu/h7.33 kW; at 95°F it is 15,900 Btu/h4.66 kW above the example cooling load of 12,500 Btu/h3.66 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h7.33 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h3.66 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218389024 · listed by GREE · certified Apr 17, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 26,4007.74 kW | +6% | 1.81 | |
| 17°Ffull speed | 27,6008.09 kW | +8% | NR | |
| 47°Fnormal speed | 30,0008.79 kW | 0% | NR | |
| 95°Fcooling, full load | 28,4008.32 kW | — | NR |
EER2 12.2 in that test. SEER2 19.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.27kW
- Electrical input in the 95°F cooling test
- 2.33kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton mini-split models
- This pairing at 5°F
- 26,400 Btu/h7.74 kWNR
- This unit at 5°F median across its pairings
- 26,400 Btu/h7.74 kW
- Median of 2.5-ton mini-split models at 5°F
- 25,000 Btu/h7.33 kW
- Models in this group
- 405
This unit is above 57% of them, at number 173 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.
Closest models by heat at 5°F
- ML27HP230MULH - OMainline · 27,000 Btu/h
- MO4GX-H27B-2AMidea · 27,000 Btu/h
- MXZ-3C30NAHZ4Mitsubishi Electric · 26,800 Btu/h
- MMPD036S6M-1PLennox · 26,400 Btu/h
- ASH3036UCDDGE · 26,200 Btu/h
- 1G3036ED2BEGE · 26,000 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for GS4M30HP230V1MO
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 30,000 Btu/h8.79 kWNR | 30,000 Btu/h8.79 kW |
| Heat output at 17°F full speed | 27,600 Btu/h8.09 kWNR | 27,200–28,000 Btu/h7.97–8.21 kW |
| Heat output at 5°F full speed | 26,400 Btu/h7.74 kWNR | 26,000–27,000 Btu/h7.62–7.91 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 88%NR | |
| COP at 5°F full speed | 1.81NR | 1.81–2.07 |
| HSPF2 Region IV | 9.0NR | 8.1–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 28,400 Btu/h8.32 kWNR | 28,400 Btu/h8.32 kW |
| EER2 at 95°F | 12.2NR | 12.0–13.6 |
| SEER2 cooling season | 19.0NR | 18.0–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | GS4M30HP230V1MO | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) GREE 26,400 Btu/h7.74 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | GREE | 26,4007.74 | 30,0008.79 | 28,4008.32 | 88% | 1.88 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
20 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH30-H2Air Max
- BXM2Z30UC0Blueridge
- DXH30FMK3IHAireForce · Airtemp · Gibson · Intertherm
- GWHD(30)ND6MOGree
- GWHD21-30H3DTosot
- KM30X6OKinghome
- MHPC-D-030BMCAC Pro
- MUL30HP230V1R32AOGree
- MUL30HPJ132OABoreal
- MZ-COSMO30/OTosot
- MZUHW30KR32-OWillis
- OFRM4X1-H30A-OOuellet
- QVMZ30*R32QuébecVair
- TM30D6MOTosot
- TM30H32MOTosot
- TM30R32MOTosot
- TM30WH21MOTosot
- TMH30D32MOTosot
- TMSCI7H4R30Tosot
19 of 20 shown.
Other model numbers with identical certified values
19 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH30-H2identical certified values
- BXM2Z30UC0identical certified values
- GWHD(30)ND6MOidentical certified values
- GWHD21-30H3Didentical certified values
- KM30X6Oidentical certified values
- MHPC-D-030BMCidentical certified values
- MUL30HP230V1R32AOidentical certified values
- MUL30HPJ132OAidentical certified values
- MZ-COSMO30/Oidentical certified values
- MZUHW30KR32-Oidentical certified values
- OFRM4X1-H30A-Oidentical certified values
- QVMZ30*R32identical certified values
- TM30D6MOidentical certified values
- TM30H32MOidentical certified values
- TM30R32MOidentical certified values
- TM30WH21MOidentical certified values
- TMH30D32MOidentical certified values
- TMSCI7H4R30identical certified values
18 of 19 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 17, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read