MUL30HP230V1R32AO
Gree · mini-split heat pump
MUL30HP230V1R32AO is in the certified data as of Sep 19, 2026. MUL30HP230V1R32AO changed its certified HSPF2 on AHRI certificate 215218920 from 8.0 to 8.1 in the certified data between September 2024 and November 2024.
- 30,000 Btu (2.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
30,0008.79NR
No 47°F rating for this pairing.
27,6008.09NR at 17°F
26,4007.74NR at 5°F
Btu/hkW, certified
1.81NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 30,000 Btu/h8.79 kW of heat at 47°F, 27,600 Btu/h8.09 kW at 17°F, and 26,400 Btu/h7.74 kW at 5°F, 88% of its 47°F rating. It delivers 28,400 Btu/h8.32 kW of cooling at 95°F. At 5°F that is 1,400 Btu/h0.41 kW above the example heating load of 25,000 Btu/h7.33 kW; at 95°F it is 15,900 Btu/h4.66 kW above the example cooling load of 12,500 Btu/h3.66 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h7.33 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h3.66 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215218925 · listed by GREE · certified Apr 21, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 26,4007.74 kW | +6% | 1.81 | |
| 17°Ffull speed | 27,6008.09 kW | +8% | NR | |
| 47°Fnormal speed | 30,0008.79 kW | 0% | NR | |
| 95°Fcooling, full load | 28,4008.32 kW | — | NR |
EER2 12.2 in that test. SEER2 19.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.27kW
- Electrical input in the 95°F cooling test
- 2.33kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton mini-split models
- This pairing at 5°F
- 26,400 Btu/h7.74 kWNR
- This unit at 5°F median across its pairings
- 26,400 Btu/h7.74 kW
- Median of 2.5-ton mini-split models at 5°F
- 25,000 Btu/h7.33 kW
- Models in this group
- 405
This unit is above 57% of them, at number 173 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.
Among 30,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 180th of 405 (tied); HSPF2, 275th of 405 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- AOD30-30HFN1-MS0W: The same 30,000 Btu/h rating at 47°F; 17,500 Btu/h at 5°F (this model: 26,400).
- ADSZ130DA: The same 30,000 Btu/h rating at 47°F; 18,000 Btu/h at 5°F (this model: 26,400).
- MOD-30HFN1CA: The same 30,000 Btu/h rating at 47°F; 18,400 Btu/h at 5°F (this model: 26,400).
Closest models by heat at 5°F
- MO4GX-H27B-2AMidea · 27,000 Btu/h
- MXZ-3C30NAHZ4Mitsubishi Electric · 26,800 Btu/h
- MMPD036S6M-1PLennox · 26,400 Btu/h
- ASH3036UCDDGE · 26,200 Btu/h
- 1G3036ED2BEGE · 26,000 Btu/h
- PAS-30BUFASDQ1-LACHitachi · 26,000 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 26,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 630–1,100 |
| Mild | Typical | 16–26 | 1,020–1,650 |
| Mild | Tight, well insulated | 10–18 | 1,470–2,640 |
| Cold | Drafty, little insulation | 28–52 | 510–940 |
| Cold | Typical | 18–30 | 880–1,470 |
| Cold | Tight, well insulated | 12–22 | 1,200–2,200 |
| Very cold | Drafty, little insulation | 32–58 | 460–830 |
| Very cold | Typical | 22–38 | 690–1,200 |
| Very cold | Tight, well insulated | 16–28 | 940–1,650 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for MUL30HP230V1R32AO
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 30,000 Btu/h8.79 kWNR | 30,000 Btu/h8.79 kW |
| Heat output at 17°F full speed | 27,600 Btu/h8.09 kWNR | 27,200–28,000 Btu/h7.97–8.21 kW |
| Heat output at 5°F full speed | 26,400 Btu/h7.74 kWNR | 26,000–27,000 Btu/h7.62–7.91 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 88%NR | |
| COP at 5°F full speed | 1.81NR | 1.81–2.07 |
| HSPF2 Region IV | 9.0NR | 8.1–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 28,400 Btu/h8.32 kWNR | 28,400 Btu/h8.32 kW |
| EER2 at 95°F | 12.2NR | 12.0–13.6 |
| SEER2 cooling season | 19.0NR | 18.0–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MUL30HP230V1R32AO | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) GREE 26,400 Btu/h7.74 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | GREE | 26,4007.74 | 30,0008.79 | 28,4008.32 | 88% | 1.88 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
20 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH30-H2Air Max
- BXM2Z30UC0Blueridge
- DXH30FMK3IHAireForce · Airtemp · Gibson · Intertherm
- GS4M30HP230V1MOGree
- GWHD(30)ND6MOGree
- GWHD21-30H3DTosot
- KM30X6OKinghome
- MHPC-D-030BMCAC Pro
- MUL30HPJ132OABoreal
- MZ-COSMO30/OTosot
- MZUHW30KR32-OWillis
- OFRM4X1-H30A-OOuellet
- QVMZ30*R32QuébecVair
- TM30D6MOTosot
- TM30H32MOTosot
- TM30R32MOTosot
- TM30WH21MOTosot
- TMH30D32MOTosot
- TMSCI7H4R30Tosot
19 of 20 shown.
Other model numbers with identical certified values
19 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH30-H2identical certified values
- BXM2Z30UC0identical certified values
- GS4M30HP230V1MOidentical certified values
- GWHD(30)ND6MOidentical certified values
- GWHD21-30H3Didentical certified values
- KM30X6Oidentical certified values
- MHPC-D-030BMCidentical certified values
- MUL30HPJ132OAidentical certified values
- MZ-COSMO30/Oidentical certified values
- MZUHW30KR32-Oidentical certified values
- OFRM4X1-H30A-Oidentical certified values
- QVMZ30*R32identical certified values
- TM30D6MOidentical certified values
- TM30H32MOidentical certified values
- TM30R32MOidentical certified values
- TM30WH21MOidentical certified values
- TMH30D32MOidentical certified values
- TMSCI7H4R30identical certified values
18 of 19 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MUL30HP230V1R32AO changed its certified HSPF2 on AHRI certificate 215218920 from 8.0 to 8.1 in the certified data between September 2024 and November 2024.
- MUL30HP230V1R32AO was in the certified data by September 2024.
History and definitions
Other Multi R32 AO models by nominal cooling size: MUE18HP230V1R32AO (18,000 Btu), MUL18HP230V1R32AO (18,000 Btu), MUE24HP230V1R32AO (24,000 Btu), MUE30HP230V1R32AO (30,000 Btu), MUE36HP230V1R32AO (36,000 Btu), MUE42HP230V1R32AO (42,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 21, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read