GWHD(36)ND6CO
Gree · mini-split heat pump
GWHD(36)ND6CO is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
36,00010.55NR
No 47°F rating for this pairing.
36,00010.55NR at 17°F
34,0009.96NR at 5°F
Btu/hkW, certified
1.84NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 36,000 Btu/h10.55 kW of heat at 47°F, 36,000 Btu/h10.55 kW at 17°F, and 34,000 Btu/h9.96 kW at 5°F, 94% of its 47°F rating. It delivers 36,000 Btu/h10.55 kW of cooling at 95°F. At 5°F that is 3,000 Btu/h0.88 kW above the example heating load of 31,000 Btu/h9.09 kW; at 95°F it is 20,500 Btu/h6.01 kW above the example cooling load of 15,500 Btu/h4.54 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,300 sq ft where winters reach 5°F: heating runs from 31,000 Btu/h9.09 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 15,500 Btu/h4.54 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218457875 · listed by GREE · certified Jun 1, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 34,0009.96 kW | +10% | 1.84 | |
| 17°Ffull speed | 36,00010.55 kW | +22% | NR | |
| 47°Fnormal speed | 36,00010.55 kW | −3% | NR | |
| 95°Fcooling, full load | 36,00010.55 kW | — | NR |
EER2 11.8 in that test. SEER2 19.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.42kW
- Electrical input in the 95°F cooling test
- 3.05kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton mini-split models
- This pairing at 5°F
- 34,000 Btu/h9.96 kWNR
- This unit at 5°F median across its pairings
- 34,000 Btu/h9.96 kW
- Median of 3-ton mini-split models at 5°F
- 31,000 Btu/h9.09 kW
- Models in this group
- 553
This unit is above 61% of them, at number 218 of 553 by heat at 5°F. The middle half of the group runs 26,000 to 36,000 Btu/h.
Closest models by heat at 5°F
- MLB036S4M-1PLennox · 34,400 Btu/h
- FPHMR36A3DFriedrich, Rheem + 1 more · 34,200 Btu/h
- 37VMB036HDS3-1Bryant, Carrier + 1 more · 34,000 Btu/h
- LUU360HHVLG · 33,800 Btu/h
- LUU360HVLG · 33,600 Btu/h
- ACIQ-36Z-E-HH-M4ACiQ · 33,400 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for GWHD(36)ND6CO
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| Heat output at 17°F full speed | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| Heat output at 5°F full speed | 34,000 Btu/h9.96 kWNR | 33,000–36,000 Btu/h9.67–10.55 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 94%NR | |
| COP at 5°F full speed | 1.84NR | 1.84–2.10 |
| HSPF2 Region IV | 9.0NR | 8.1–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| EER2 at 95°F | 11.8NR | 11.7–12.0 |
| SEER2 cooling season | 19.0NR | 18.0–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | GWHD(36)ND6CO | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) GREE 34,000 Btu/h9.96 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | GREE | 34,0009.96 | 36,00010.55 | 36,00010.55 | 94% | 1.90 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
23 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH36-H2Air Max
- BXM2Z36UC0Blueridge
- DXH36FMK3IHAireForce · Airtemp · Gibson · Intertherm
- GMRSHC36AS4Classic
- GMRSHT36AS4TGM
- GS4M36HP230V1MOGree
- GWHD(36)ND6MOGree
- GWHD21-36H4DTosot
- KM36X6OKinghome
- MHPC-D-036BMCAC Pro
- MUL36HP230V1R32AOGree
- MUL36HPJ132OABoreal
- MZ-COSMO36/OTosot
- MZUHW36KR32-OWillis
- OFRM4X1-H36A-OOuellet
- QVMZ36*R32QuébecVair
- TM36D6MOTosot
- TM36H32MOTosot
- TM36R32MOTosot
- TM36WH21MOTosot
- TMH36D32MOTosot
- TMSCI7H4R36Tosot
22 of 23 shown.
Other model numbers with identical certified values
22 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH36-H2identical certified values
- BXM2Z36UC0identical certified values
- GMRSHC36AS4identical certified values
- GMRSHT36AS4identical certified values
- GS4M36HP230V1MOidentical certified values
- GWHD(36)ND6MOidentical certified values
- GWHD21-36H4Didentical certified values
- KM36X6Oidentical certified values
- MHPC-D-036BMCidentical certified values
- MUL36HP230V1R32AOidentical certified values
- MUL36HPJ132OAidentical certified values
- MZ-COSMO36/Oidentical certified values
- MZUHW36KR32-Oidentical certified values
- OFRM4X1-H36A-Oidentical certified values
- QVMZ36*R32identical certified values
- TM36D6MOidentical certified values
- TM36H32MOidentical certified values
- TM36R32MOidentical certified values
- TM36WH21MOidentical certified values
- TMH36D32MOidentical certified values
- TMSCI7H4R36identical certified values
21 of 22 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 1, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read