GWHD(36)ND6MO
Gree · mini-split heat pump
GWHD(36)ND6MO is in the certified data as of Oct 2, 2026. GWHD(36)ND6MO changed its certified EER2 on AHRI certificate 214931595 from 11.7 to 11.0 in the certified data between Oct 1, 2026 and Oct 2, 2026.
- 36,000 Btu (3-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
36,00010.55NR
No 47°F rating for this pairing.
36,00010.55NR at 17°F
34,0009.96NR at 5°F
Btu/hkW, certified
1.84NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 36,000 Btu/h10.55 kW of heat at 47°F, 36,000 Btu/h10.55 kW at 17°F, and 34,000 Btu/h9.96 kW at 5°F, 94% of its 47°F rating. It delivers 36,000 Btu/h10.55 kW of cooling at 95°F. At 5°F that is 3,000 Btu/h0.88 kW above the example heating load of 31,000 Btu/h9.09 kW; at 95°F it is 20,500 Btu/h6.01 kW above the example cooling load of 15,500 Btu/h4.54 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,300 sq ft where winters reach 5°F: heating runs from 31,000 Btu/h9.09 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 15,500 Btu/h4.54 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214931599 · listed by GREE · certified Apr 21, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 34,0009.96 kW | +10% | 1.84 | |
| 17°Ffull speed | 36,00010.55 kW | +22% | NR | |
| 47°Fnormal speed | 36,00010.55 kW | −3% | NR | |
| 95°Fcooling, full load | 36,00010.55 kW | — | NR |
EER2 11.8 in that test. SEER2 19.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.42kW
- Electrical input in the 95°F cooling test
- 3.05kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton mini-split models
- This pairing at 5°F
- 34,000 Btu/h9.96 kWNR
- This unit at 5°F median across its pairings
- 34,000 Btu/h9.96 kW
- Median of 3-ton mini-split models at 5°F
- 31,000 Btu/h9.09 kW
- Models in this group
- 553
This unit is above 61% of them, at number 218 of 553 by heat at 5°F. The middle half of the group runs 26,000 to 36,000 Btu/h.
Closest models by heat at 5°F
- MLB036S4M-1PLennox · 34,400 Btu/h
- FPHMR36A3DFriedrich, Rheem + 1 more · 34,200 Btu/h
- 37VMB036HDS3-1Bryant, Carrier + 1 more · 34,000 Btu/h
- LUU360HHVLG · 33,800 Btu/h
- LUU360HVLG · 33,600 Btu/h
- ACIQ-36Z-E-HH-M4ACiQ · 33,400 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for GWHD(36)ND6MO
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| Heat output at 17°F full speed | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| Heat output at 5°F full speed | 34,000 Btu/h9.96 kWNR | 33,000–36,000 Btu/h9.67–10.55 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 94%NR | |
| COP at 5°F full speed | 1.84NR | 1.84–2.10 |
| HSPF2 Region IV | 9.0NR | 8.1–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 36,000 Btu/h10.55 kWNR | 32,000–36,000 Btu/h9.38–10.55 kW |
| EER2 at 95°F | 11.8NR | 11.0–12.0 |
| SEER2 cooling season | 19.0NR | 18.0–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | GWHD(36)ND6MO | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) GREE 34,000 Btu/h9.96 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | GREE | 34,0009.96 | 36,00010.55 | 36,00010.55 | 94% | 1.90 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
23 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH36-H2Air Max
- BXM2Z36UC0Blueridge
- DXH36FMK3IHAireForce · Airtemp · Gibson · Intertherm
- GMRSHC36AS4Classic
- GMRSHT36AS4TGM
- GS4M36HP230V1MOGree
- GWHD(36)ND6COGree
- GWHD21-36H4DTosot
- KM36X6OKinghome
- MHPC-D-036BMCAC Pro
- MUL36HP230V1R32AOGree
- MUL36HPJ132OABoreal
- MZ-COSMO36/OTosot
- MZUHW36KR32-OWillis
- OFRM4X1-H36A-OOuellet
- QVMZ36*R32QuébecVair
- TM36D6MOTosot
- TM36H32MOTosot
- TM36R32MOTosot
- TM36WH21MOTosot
- TMH36D32MOTosot
- TMSCI7H4R36Tosot
22 of 23 shown.
Other model numbers with identical certified values
22 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AFMKH36-H2identical certified values
- BXM2Z36UC0identical certified values
- GMRSHC36AS4identical certified values
- GMRSHT36AS4identical certified values
- GS4M36HP230V1MOidentical certified values
- GWHD(36)ND6COidentical certified values
- GWHD21-36H4Didentical certified values
- KM36X6Oidentical certified values
- MHPC-D-036BMCidentical certified values
- MUL36HP230V1R32AOidentical certified values
- MUL36HPJ132OAidentical certified values
- MZ-COSMO36/Oidentical certified values
- MZUHW36KR32-Oidentical certified values
- OFRM4X1-H36A-Oidentical certified values
- QVMZ36*R32identical certified values
- TM36D6MOidentical certified values
- TM36H32MOidentical certified values
- TM36R32MOidentical certified values
- TM36WH21MOidentical certified values
- TMH36D32MOidentical certified values
- TMSCI7H4R36identical certified values
21 of 22 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- GWHD(36)ND6MO changed its certified EER2 on AHRI certificate 214931595 from 11.7 to 11.0 in the certified data between Oct 1, 2026 and Oct 2, 2026.
- GWHD(36)ND6MO changed its certified cooling capacity at 95°F on AHRI certificate 214931595 from 36,000 Btu/h to 32,000 Btu/h in the certified data between Oct 1, 2026 and Oct 2, 2026.
- GWHD(36)ND6MO changed its certified HSPF2 on AHRI certificate 214931595 from 8.0 to 8.1 in the certified data between September 2024 and November 2024.
- GWHD(36)ND6MO was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 21, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read