LMU243HV
LMU243HV is in the certified data.
Its certified full-speed heating output at 5°F is 15,600–15,800 Btu/h4.57–4.63 kW, 64–68% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
LG · mini-split heat pump
LMU243HV is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
23,8006.98NR
No 47°F rating for this pairing.
14,7004.31NR at 17°F
15,7004.60NR at 5°F
Btu/hkW, certified
2.14NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 23,800 Btu/h6.98 kW of heat at 47°F, 14,700 Btu/h4.31 kW at 17°F, and 15,700 Btu/h4.60 kW at 5°F, 66% of its 47°F rating. It delivers 23,000 Btu/h6.74 kW of cooling at 95°F. At 5°F that is 3,300 Btu/h0.97 kW short of the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 13,500 Btu/h3.96 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 208132538 · listed by LG · certified Jan 14, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 4 programs in 2 states, provinces, or territories:British Columbia (3), Newfoundland and Labrador (1).
All 4 programs by state and province
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Newfoundland and Labrador
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 15,7004.60 kW | −17% | 2.14 | |
| 17°Ffull speed | 14,7004.31 kW | −27% | NR | |
| 47°Fnormal speed | 23,8006.98 kW | −5% | NR | |
| 95°Fcooling, full load | 23,0006.74 kW | — | NR |
EER2 12.5 in that test. SEER2 20.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.15kW
- Electrical input in the 95°F cooling test
- 1.84kW
- Seasonal average heating COP
- 2.70
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 15,700 Btu/h4.60 kWNR
- This unit at 5°F median across its pairings
- 15,700 Btu/h4.60 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 6% of them, at number 858 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Among 24,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 839th of 917; HSPF2, 686th of 927 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- CU-4Z24BBUC: 24,000 Btu/h at 47°F (this model: 23,800); 27,000 Btu/h at 5°F (this model: 15,700).
- AM3-H24/2DR3B: 24,000 Btu/h at 47°F (this model: 23,800); 26,000 Btu/h at 5°F (this model: 15,700).
- AOU24RLXFZH: 24,000 Btu/h at 47°F (this model: 23,800); 25,600 Btu/h at 5°F (this model: 15,700).
Closest models by heat at 5°F
- TWH24AG25A2DOTosot · 16,100 Btu/h
- TSC-24HA2/I3TI20TCL · 16,000 Btu/h
- GWH24ATEXF-D6DNA1F/OGree · 15,700 Btu/h
- SU-COSMO24-230/OTosot · 15,700 Btu/h
- NTXSKS24A112Trane / Mitsubishi Electric · 15,600 Btu/h
- SUZ-KA24NAMitsubishi Electric and Trane / Mitsubishi Electric · 15,600 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 15,700 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 370–650 |
| Mild | Typical | 16–26 | 600–980 |
| Mild | Tight, well insulated | 10–18 | 870–1,570 |
| Cold | Drafty, little insulation | 28–52 | 300–560 |
| Cold | Typical | 18–30 | 520–870 |
| Cold | Tight, well insulated | 12–22 | 710–1,310 |
| Very cold | Drafty, little insulation | 32–58 | 270–490 |
| Very cold | Typical | 22–38 | 410–710 |
| Very cold | Tight, well insulated | 16–28 | 560–980 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for LMU243HV
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 23,800 Btu/h6.98 kWNR | 23,000–24,600 Btu/h6.74–7.21 kW |
| Heat output at 17°F full speed | 14,700 Btu/h4.31 kWNR | 14,600–14,900 Btu/h4.28–4.37 kW |
| Heat output at 5°F full speed | 15,700 Btu/h4.60 kWNR | 15,600–15,800 Btu/h4.57–4.63 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 66%NR | |
| COP at 5°F full speed | 2.14NR | 2.10–2.18 |
| HSPF2 Region IV | 9.2NR | 9.0–9.4 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 23,000 Btu/h6.74 kWNR | 22,000–24,000 Btu/h6.45–7.03 kW |
| EER2 at 95°F | 12.5NR | 12.5 |
| SEER2 cooling season | 20.5NR | 18.5–22.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | Canada | Canada |
| Model string as certified | LMU243HV | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) LG 15,700 Btu/h4.60 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | LG | 15,7004.60 | 23,8006.98 | 23,0006.74 | 66% | 2.14 | NC | 3 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 14, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read