TSC-24HA2/I3TI20
TSC-24HA2/I3TI20 is in the certified data.
Its certified full-speed heating output at 5°F is 16,000 Btu/h4.69 kW, 67% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
TCL · mini-split heat pump
TSC-24HA2/I3TI20 is in the certified data as of Sep 19, 2026. TSC-24HA2/I3TI20 changed its certified heat output at 47°F on AHRI certificate 207688892 from 23,000 Btu/h to 24,000 Btu/h in the certified data between August 2025 and September 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
24,0007.03NR
No 47°F rating for this pairing.
13,9004.07NR at 17°F
16,0004.69NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 24,000 Btu/h7.03 kW of heat at 47°F, 13,900 Btu/h4.07 kW at 17°F, and 16,000 Btu/h4.69 kW at 5°F, 67% of its 47°F rating. It delivers 23,000 Btu/h6.74 kW of cooling at 95°F. At 5°F that is 3,000 Btu/h0.88 kW short of the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 13,500 Btu/h3.96 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 207688892 · listed by TCL · certified Oct 17, 2025 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 16,0004.69 kW | −16% | 1.80 | |
| 17°Ffull speed | 13,9004.07 kW | −31% | NR | |
| 47°Fnormal speed | 24,0007.03 kW | −4% | NR | |
| 95°Fcooling, full load | 23,0006.74 kW | — | NR |
EER2 12.5 in that test. SEER2 20.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.61kW
- Electrical input in the 95°F cooling test
- 1.84kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 16,000 Btu/h4.69 kWNR
- This unit at 5°F median across its pairings
- 16,000 Btu/h4.69 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 7% of them, at number 849 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Closest models by heat at 5°F
- DIYP-24-HP-C-230DE11-OMRCOOL · 16,100 Btu/h
- GWH24AGEXH-D3DNA1A/OGree · 16,100 Btu/h
- TWH24AG25A2DOTosot · 16,100 Btu/h
- GWH24ATEXF-D6DNA1F/OGree · 15,700 Btu/h
- LMU243HVLG · 15,700 Btu/h
- SU-COSMO24-230/OTosot · 15,700 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for TSC-24HA2/I3TI20
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 24,000 Btu/h7.03 kWNR | 24,000 Btu/h7.03 kW |
| Heat output at 17°F full speed | 13,900 Btu/h4.07 kWNR | 13,900 Btu/h4.07 kW |
| Heat output at 5°F full speed | 16,000 Btu/h4.69 kWNR | 16,000 Btu/h4.69 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 67%NR | |
| COP at 5°F full speed | 1.80NR | 1.80 |
| HSPF2 Region IV | 9.0NR | 9.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 23,000 Btu/h6.74 kWNR | 23,000 Btu/h6.74 kW |
| EER2 at 95°F | 12.5NR | 12.5 |
| SEER2 cooling season | 20.0NR | 20.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | TSC-24HA2/I3TI20-I | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | TSC-24HA2/I3TI20 | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
TSC-24HA2/I3TI20-I (the pairing on screen) TCL 16,000 Btu/h4.69 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| TSC-24HA2/I3TI20-I (the pairing on screen) | TCL | 16,0004.69 | 24,0007.03 | 23,0006.74 | 67% | 1.80 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
13 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 048-TP-24K2V-20S-OUTDella
- ALPCI4H4E24Air-Con
- ASXCI4H4E24Air-Con
- ATPRO23-24H1BApooDr
- CHT24CD-23(O)ComfortStar
- CMS24 PROAcekool
- FES-24H2TK-ES(O)Fujieco
- GL24K230-OTurbro
- KWSM-24IR410AHS20KANIONco
- LWSM-24IR410AHS20Live Cool
- MCH24-CS-S23-OClima Smart
- MSCT-24HAC2-OClassic America
12 of 13 shown.
Other model numbers with identical certified values
13 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 048-TP-24K2V-20S-OUTidentical certified values
- ALPCI4H4E24identical certified values
- ASXCI4H4E24identical certified values
- ATPRO23-24H1Bidentical certified values
- CHT24CD-23(O)identical certified values
- CMS24 PROidentical certified values
- FES-24H2TK-ES(O)identical certified values
- GL24K230-Oidentical certified values
- KWSM-24IR410AHS20identical certified values
- LWSM-24IR410AHS20identical certified values
- MCH24-CS-S23-Oidentical certified values
- MSCT-24HAC2-Oidentical certified values
12 of 13 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- TSC-24HA2/I3TI20 changed its certified heat output at 47°F on AHRI certificate 207688892 from 23,000 Btu/h to 24,000 Btu/h in the certified data between August 2025 and September 2026.
- TSC-24HA2/I3TI20 changed its certified heat output at 47°F on AHRI certificate 207688892 from 24,000 Btu/h to 23,000 Btu/h in the certified data between March 2025 and May 2025.
- TSC-24HA2/I3TI20 was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 17, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read