NS17H24SA4-**A

NS17H24SA4-**A is in the certified data.

Its certified full-speed heating output at 5°F is 10,200–11,500 Btu/h, 47–51% of its 47°F rating, depending on the pairing.

GE · central heat pump

NS17H24SA4-**A is in the certified data as of Sep 27, 2026.

253 certified pairings with 69 different figures. See all

Certified heating and cooling

Heating at 47°F

21,400

13,600 at 17°F

10,400 at 5°F

Btu/h, certified

2.04 COP at 5°F

Cooling at 95°F

23,400

Btu/h, certified

EER2 13.0 at 95°F

SEER2 16.4

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for NS17H24SA4-**A, by outdoor temperature Heating: 10,400 Btu/h at 5°F, 13,600 Btu/h at 17°F, 21,400 Btu/h at 47°F. Cooling: 23,400 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 10,400 5°F 13,600 17°F 21,400 47°F 23,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 21,400 Btu/h of heat at 47°F, 13,600 Btu/h at 17°F, and 10,400 Btu/h at 5°F, 49% of its 47°F rating. It delivers 23,400 Btu/h of cooling at 95°F. At 5°F that is 8,600 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 13,900 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 210262033 · listed by GE · certified Oct 27, 2025 · 16 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 10,4003.05 kW −45% 2.04
17°Fone compressor speed 13,6003.99 kW −29% NR
47°Fone compressor speed 21,4006.27 kW −11% NR
95°Fcooling, full load 23,4006.86 kW — NR

EER2 13.0 in that test. SEER2 16.4 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.49kW
Electrical input in the 95°F cooling test
1.80kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 27, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
10,400 Btu/h
This unit at 5°F median across its pairings
10,400 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 3% of them, at number 547 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for NS17H24SA4-**A

253 pairings · 253 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for NS17H24SA4-**A
This pairingAll pairings
Heating
Heat output at 47°F one speed 21,400 Btu/h 21,200–22,600 Btu/h
Heat output at 17°F full speed 13,600 Btu/h 13,400–14,700 Btu/h
Heat output at 5°F full speed 10,400 Btu/h 10,200–11,500 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 49%
COP at 5°F full speed 2.04 2.00–2.16
HSPF2 Region IV 7.8 7.8–8.2
Cooling
Cooling capacity at 95°F full-load test 23,400 Btu/h 22,600–24,000 Btu/h
EER2 at 95°F 13.0 12.5–14.0
SEER2 cooling season 16.4 15.4–17.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Single stage
Indoor unit NCUU24BP4+TDR+TXV 28 indoor units
FurnaceNF80U070S3B-* 71 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold United States US and Canada
Model string as certified NS17H24SA4-**A

Pairings, by indoor-unit class

28 indoor units · 253 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. NCHC30BT5D-**+TDR brand not stated 10,400 Btu/hat 5°F, full speed

    20 pairings, 20 with a furnace · 47°F 21,600 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 48% · COP 2.06

  2. NCUC24BT5D-**+TDR brand not stated 10,400 Btu/hat 5°F, full speed

    19 pairings, 19 with a furnace · 47°F 21,600 Btu/h · 95°F cooling 23,400 Btu/h · Cold output 49% · COP 2.04

  3. NCUC30BT5D-**+TDR brand not stated 10,400 Btu/hat 5°F, full speed

    19 pairings, 19 with a furnace · 47°F 21,400 Btu/h · 95°F cooling 23,000 Btu/h · Cold output 49% · COP 2.06

  4. NCHC30BT4+TDR brand not stated 10,400 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 21,600 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 49% · COP 2.06

  5. NCUC24BT4+TDR brand not stated 10,400 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 21,600 Btu/h · 95°F cooling 23,400 Btu/h · Cold output 49% · COP 2.04

  6. NCUC30BT4+TDR brand not stated 10,400 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 21,400 Btu/h · 95°F cooling 23,000 Btu/h · Cold output 49% · COP 2.06

  7. NCUU24BP4+TDR+TXV (the pairing on screen) brand not stated 10,400 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 21,600 Btu/h · 95°F cooling 23,400 Btu/h · Cold output 49% · COP 2.04

  8. NCUU30BP4+TDR+TXV brand not stated 10,400 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 21,400 Btu/h · 95°F cooling 23,000 Btu/h · Cold output 49% · COP 2.06

  9. NCHC24AT5D-**+TDR brand not stated 10,400 Btu/hat 5°F, full speed

    10 pairings, 10 with a furnace · 47°F 21,400 Btu/h · 95°F cooling 23,200 Btu/h · Cold output 49% · COP 2.04

  10. NCHC30AT5D-**+TDR brand not stated 10,400 Btu/hat 5°F, full speed

    10 pairings, 10 with a furnace · 47°F 21,600 Btu/h · 95°F cooling 23,700 Btu/h · Cold output 48% · COP 2.12

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
NCHC30BT5D-**+TDR — 10,400 21,600 23,600 48% 2.06 NC 20
NCUC24BT5D-**+TDR — 10,400 21,600 23,400 49% 2.04 NC 19
NCUC30BT5D-**+TDR — 10,400 21,400 23,000 49% 2.06 NC 19
NCHC30BT4+TDR — 10,400 21,600 23,600 49% 2.06 NC 16
NCUC24BT4+TDR — 10,400 21,600 23,400 49% 2.04 NC 16
NCUC30BT4+TDR — 10,400 21,400 23,000 49% 2.06 NC 16
NCUU24BP4+TDR+TXV (the pairing on screen) — 10,400 21,600 23,400 49% 2.04 NC 16
NCUU30BP4+TDR+TXV — 10,400 21,400 23,000 49% 2.06 NC 16
NCHC24AT5D-**+TDR — 10,400 21,400 23,200 49% 2.04 NC 10
NCHC30AT5D-**+TDR — 10,400 21,600 23,700 48% 2.12 NC 10

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 28 indoor units All 253 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Oct 27, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “NS17H24SA4-**A — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/ns17h24sa4-_st_sta