NS17H30SA4-**A
NS17H30SA4-**A is in the certified data.
Its certified full-speed heating output at 5°F is 13,200–15,400 Btu/h3.87–4.51 kW, 49–53% of its 47°F rating, depending on the pairing.
GE · central heat pump
NS17H30SA4-**A is in the certified data as of Sep 27, 2026.
- 30,000 Btu (2.5-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
27,6008.09NR
No 47°F rating for this pairing.
18,2005.33NR at 17°F
14,4004.22NR at 5°F
Btu/hkW, certified
2.28NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 27,600 Btu/h8.09 kW of heat at 47°F, 18,200 Btu/h5.33 kW at 17°F, and 14,400 Btu/h4.22 kW at 5°F, 52% of its 47°F rating. It delivers 29,400 Btu/h8.62 kW of cooling at 95°F. At 5°F that is 8,100 Btu/h2.37 kW short of the example heating load of 22,500 Btu/h6.59 kW; at 95°F it is 17,900 Btu/h5.25 kW above the example cooling load of 11,500 Btu/h3.37 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h6.59 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h3.37 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210262255 · listed by GE · certified Oct 27, 2025 · 10 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 14,4004.22 kW | −36% | 2.28 | |
| 17°Fone compressor speed | 18,2005.33 kW | −12% | NR | |
| 47°Fone compressor speed | 27,6008.09 kW | −8% | NR | |
| 95°Fcooling, full load | 29,4008.62 kW | — | NR |
EER2 13.0 in that test. SEER2 16.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.85kW
- Electrical input in the 95°F cooling test
- 2.26kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton central models
- This pairing at 5°F
- 14,400 Btu/h4.22 kWNR
- This unit at 5°F median across its pairings
- 14,400 Btu/h4.22 kW
- Median of 2.5-ton central models at 5°F
- 22,400 Btu/h6.56 kW
- Models in this group
- 288
This unit is above 25% of them, at number 215 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.
Closest models by heat at 5°F
- BHP17L30P-**ABlueridge · 14,400 Btu/h
- HRG1530S1R-**ACentury and Comfort-Aire · 14,400 Btu/h
- ML17XP1-030-230ALennox · 14,400 Btu/h
- MHP17030A-**AMRCOOL · 14,300 Btu/h
- FRP15AZ30AJ2NFriedrich · 14,100 Btu/h
- 27SCA531A**30*Carrier · 14,000 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for NS17H30SA4-**A
248 pairings · 248 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 27,600 Btu/h8.09 kWNR | 26,600–30,000 Btu/h7.80–8.79 kW |
| Heat output at 17°F full speed | 18,200 Btu/h5.33 kWNR | 17,400–19,600 Btu/h5.10–5.74 kW |
| Heat output at 5°F full speed | 14,400 Btu/h4.22 kWNR | 13,200–15,400 Btu/h3.87–4.51 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 52%NR | |
| COP at 5°F full speed | 2.28NR | 1.96–2.38 |
| HSPF2 Region IV | 8.1NR | 7.8–8.6 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 29,400 Btu/h8.62 kWNR | 28,200–30,000 Btu/h8.26–8.79 kW |
| EER2 at 95°F | 13.0NR | 12.2–13.5 |
| SEER2 cooling season | 16.0NR | 15.2–16.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Single stage | |
| Indoor unit | NCUU36AP4+TDR+TXV | 29 indoor units |
| Furnace | NF80U045S3A-* | 100 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | US and Canada |
| Model string as certified | NS17H30SA4-**A | |
Pairings, by indoor-unit class
29 indoor units · 248 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 10 indoor units
-
NCHC30BT5D-**+TDR (the pairing on screen) brand not stated 13,700 Btu/h4.02 kWat 5°F, full speed
-
NCHC36CT5D-**+TDR (the pairing on screen) brand not stated 14,700 Btu/h4.31 kWat 5°F, full speed
-
NCUC30BT5D-**+TDR (the pairing on screen) brand not stated 14,400 Btu/h4.22 kWat 5°F, full speed
-
NCUC36BT5D-**+TDR (the pairing on screen) brand not stated 14,400 Btu/h4.22 kWat 5°F, full speed
-
NCHC36CT4+TDR (the pairing on screen) brand not stated 14,750 Btu/h4.32 kWat 5°F, full speed
-
NCUC30BT4+TDR (the pairing on screen) brand not stated 14,450 Btu/h4.23 kWat 5°F, full speed
-
NCUC36BT4+TDR (the pairing on screen) brand not stated 14,450 Btu/h4.23 kWat 5°F, full speed
-
NCUU30BP4+TDR+TXV (the pairing on screen) brand not stated 14,450 Btu/h4.23 kWat 5°F, full speed
-
NCUU36BP4+TDR+TXV (the pairing on screen) brand not stated 14,450 Btu/h4.23 kWat 5°F, full speed
-
NCUC30AT5D-**+TDR (the pairing on screen) brand not stated 14,300 Btu/h4.19 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| NCHC30BT5D-**+TDR (the pairing on screen) | — | 13,7004.02 | 27,8008.15 | 29,5008.65 | 49% | 2.08 | NC | 20 |
| NCHC36CT5D-**+TDR (the pairing on screen) | — | 14,7004.31 | 28,4008.32 | 29,0008.50 | 52% | 2.22 | NC | 19 |
| NCUC30BT5D-**+TDR (the pairing on screen) | — | 14,4004.22 | 27,8008.15 | 29,0008.50 | 52% | 2.18 | NC | 19 |
| NCUC36BT5D-**+TDR (the pairing on screen) | — | 14,4004.22 | 28,0008.21 | 29,8008.73 | 51% | 2.26 | NC | 19 |
| NCHC36CT4+TDR (the pairing on screen) | — | 14,7504.32 | 28,4008.32 | 29,0008.50 | 52% | 2.22 | NC | 18 |
| NCUC30BT4+TDR (the pairing on screen) | — | 14,4504.23 | 27,9008.18 | 29,1008.53 | 52% | 2.18 | NC | 16 |
| NCUC36BT4+TDR (the pairing on screen) | — | 14,4504.23 | 28,0008.21 | 29,8008.73 | 51% | 2.26 | NC | 16 |
| NCUU30BP4+TDR+TXV (the pairing on screen) | — | 14,4504.23 | 27,9008.18 | 29,1008.53 | 52% | 2.18 | NC | 16 |
| NCUU36BP4+TDR+TXV (the pairing on screen) | — | 14,4504.23 | 28,0008.21 | 29,8008.73 | 51% | 2.26 | NC | 16 |
| NCUC30AT5D-**+TDR (the pairing on screen) | — | 14,3004.19 | 27,6008.09 | 28,6008.38 | 52% | 2.20 | NC | 10 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 27, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read