FRP15AZ30AJ2N

FRP15AZ30AJ2N is in the certified data.

Its certified full-speed heating output at 5°F is 14,100 Btu/h, 50% of its 47°F rating (tests at different compressor speeds) in its certified pairing.

Friedrich · central heat pump

FRP15AZ30AJ2N is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

28,400

19,700 at 17°F

14,100 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

28,400

Btu/h, certified

EER2 11.7 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for FRP15AZ30AJ2N, by outdoor temperature Heating: 14,100 Btu/h at 5°F, 19,700 Btu/h at 17°F, 28,400 Btu/h at 47°F. Cooling: 28,400 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton central models: 22,400 Btu/h at 5°F, 20,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 Btu/h 14,100 5°F 19,700 17°F 28,400 47°F 28,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 28,400 Btu/h of heat at 47°F, 19,700 Btu/h at 17°F, and 14,100 Btu/h at 5°F, 50% of its 47°F rating. It delivers 28,400 Btu/h of cooling at 95°F. At 5°F that is 8,400 Btu/h short of the example heating load of 22,500 Btu/h; at 95°F it is 16,900 Btu/h above the example cooling load of 11,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 213087939 · listed by Friedrich · certified Jun 3, 2026 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 14,1004.13 kW −37% 2.00
17°Ffull speed 19,7005.77 kW −4% NR
47°Fhigh stage 28,4008.32 kW −5% NR
95°Fcooling, full load 28,4008.32 kW — NR

EER2 11.7 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.07kW
Electrical input in the 95°F cooling test
2.43kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton central models

This pairing at 5°F
14,100 Btu/h
This unit at 5°F median across its pairings
14,100 Btu/h
Median of 2.5-ton central models at 5°F
22,400 Btu/h
Models in this group
288

This unit is above 25% of them, at number 217 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for FRP15AZ30AJ2N

1 pairing · 1 AHRI certificate

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for FRP15AZ30AJ2N
This pairingAll pairings
Heating
Heat output at 47°F high stage 28,400 Btu/h 28,400 Btu/h
Heat output at 17°F full speed 19,700 Btu/h 19,700 Btu/h
Heat output at 5°F full speed 14,100 Btu/h 14,100 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 50%
COP at 5°F full speed 2.00 2.00
HSPF2 Region IV 7.8 7.8
Cooling
Cooling capacity at 95°F full-load test 28,400 Btu/h 28,400 Btu/h
EER2 at 95°F 11.7 11.7
SEER2 cooling season 15.2 15.2
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Two-stage
Indoor unit FRH2TZ3617STANN 1 indoor unit
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified FRP15AZ30AJ2N

Pairings, by indoor-unit class

1 indoor unit · 1 certified pairing

One row per indoor unit certified with this outdoor unit.

Air handler · 1 indoor unit

  1. FRH2TZ3617STANN (the pairing on screen) brand not stated 14,100 Btu/hat 5°F, full speed

    1 pairing · 47°F 28,400 Btu/h · 95°F cooling 28,400 Btu/h · Cold output 50% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
FRH2TZ3617STANN (the pairing on screen) — 14,100 28,400 28,400 50% 2.00 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 1 of 1 indoor unit

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jun 3, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page