PH5SAN519**AA*

Brock, Bryant + 2 more · central heat pump

PH5SAN519**AA* is in the certified data as of Sep 19, 2026.

230 certified pairings with 39 different figures. See all

Certified heating and cooling

Heating at 47°F

19,400

10,900 at 17°F

8,400 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

19,200

Btu/h, certified

EER2 13.0 at 95°F

SEER2 16.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for PH5SAN519**AA*, by outdoor temperature Heating: 8,400 Btu/h at 5°F, 10,900 Btu/h at 17°F, 19,400 Btu/h at 47°F. Cooling: 19,200 Btu/h at 95°F. The bars start at zero. Median of 1.5-ton central models: 11,200 Btu/h at 5°F, 12,600 Btu/h at 17°F, 18,000 Btu/h at 47°F, 18,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 Btu/h 8,400 5°F 10,900 17°F 19,400 47°F 19,200 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 1.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 19,400 Btu/h of heat at 47°F, 10,900 Btu/h at 17°F, and 8,400 Btu/h at 5°F, 43% of its 47°F rating. It delivers 19,200 Btu/h of cooling at 95°F. At 5°F that is 2,600 Btu/h short of the example heating load of 11,000 Btu/h; at 95°F it is 13,700 Btu/h above the example cooling load of 5,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217684299 · listed by BRYANT HEATING AND COOLING SYSTEMS · certified Feb 11, 2026 · 12 pairings share these values

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 1.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 8,4002.46 kW −25% 2.00
17°Fone compressor speed 10,9003.19 kW −13% NR
47°Fone compressor speed 19,4005.69 kW +8% NR
95°Fcooling, full load 19,2005.63 kW — NR

EER2 13.0 in that test. SEER2 16.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.23kW
Electrical input in the 95°F cooling test
1.48kW
Seasonal average heating COP
2.34

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 18,000 Btu heat pumps

1.5-ton central models

This pairing at 5°F
8,400 Btu/h
This unit at 5°F median across its pairings
8,400 Btu/h
Median of 1.5-ton central models at 5°F
11,200 Btu/h
Models in this group
243

This unit is above 13% of them, at number 211 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for PH5SAN519**AA*

230 pairings · 230 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for PH5SAN519**AA*
This pairingAll pairings
Heating
Heat output at 47°F one speed 19,400 Btu/h 18,400–19,500 Btu/h
Heat output at 17°F full speed 10,900 Btu/h 10,300–11,000 Btu/h
Heat output at 5°F full speed 8,400 Btu/h 7,900–8,500 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 43%
COP at 5°F full speed 2.00 1.90–2.00
HSPF2 Region IV 8.0 7.8–8.0
Cooling
Cooling capacity at 95°F full-load test 19,200 Btu/h 17,700–19,300 Btu/h
EER2 at 95°F 13.0 12.5–13.0
SEER2 cooling season 16.0 15.2–16.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Single stage
Indoor unit CAA**2517AM* 19 indoor units
Furnace8(0,1)*SB36045M14*** 71 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified PH5SAN519**AA*

Pairings, by indoor-unit class

19 indoor units · 230 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 2 indoor units

  1. CAA**2517AM* (the pairing on screen) brand not stated 8,400 Btu/hat 5°F, full speed

    112 pairings, 66 with a furnace · 47°F 19,400 Btu/h · 95°F cooling 19,100 Btu/h · Cold output 43% · COP 2.00

  2. CAA**1917AM* brand not stated 8,300 Btu/hat 5°F, full speed

    66 pairings, 38 with a furnace · 47°F 19,400 Btu/h · 95°F cooling 19,100 Btu/h · Cold output 43% · COP 2.00

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CAA**2517AM* (the pairing on screen) — 8,400 19,400 19,100 43% 2.00 NC 112
CAA**1917AM* — 8,300 19,400 19,100 43% 2.00 NC 66

Air handler · 8 indoor units

  1. FM(C,U)5Z18**AL* brand not stated 8,100 Btu/hat 5°F, full speed

    4 pairings · 47°F 18,700 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 43% · COP 2.00

  2. FM(C,U)5Z24**AL* brand not stated 8,100 Btu/hat 5°F, full speed

    4 pairings · 47°F 18,700 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 43% · COP 2.00

  3. FM(C,U)5Z30**AL* brand not stated 8,100 Btu/hat 5°F, full speed

    4 pairings · 47°F 18,800 Btu/h · 95°F cooling 18,400 Btu/h · Cold output 43% · COP 2.00

  4. FMA5L18**AL* brand not stated 8,400 Btu/hat 5°F, full speed

    4 pairings · 47°F 19,200 Btu/h · 95°F cooling 18,300 Btu/h · Cold output 44% · COP 1.95

  5. FMA5X18**AL* brand not stated 7,900 Btu/hat 5°F, full speed

    4 pairings · 47°F 18,400 Btu/h · 95°F cooling 17,700 Btu/h · Cold output 43% · COP 2.00

  6. FMA5X24**AL* brand not stated 7,900 Btu/hat 5°F, full speed

    4 pairings · 47°F 18,400 Btu/h · 95°F cooling 17,700 Btu/h · Cold output 43% · COP 2.00

  7. PF5MN*A18L* brand not stated 8,100 Btu/hat 5°F, full speed

    4 pairings · 47°F 19,000 Btu/h · 95°F cooling 18,200 Btu/h · Cold output 43% · COP 1.90

  8. PF5MN*B24L* brand not stated 8,000 Btu/hat 5°F, full speed

    4 pairings · 47°F 18,700 Btu/h · 95°F cooling 18,100 Btu/h · Cold output 43% · COP 1.90

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
FM(C,U)5Z18**AL* — 8,100 18,700 18,000 43% 2.00 NC 4
FM(C,U)5Z24**AL* — 8,100 18,700 18,000 43% 2.00 NC 4
FM(C,U)5Z30**AL* — 8,100 18,800 18,400 43% 2.00 NC 4
FMA5L18**AL* — 8,400 19,200 18,300 44% 1.95 NC 4
FMA5X18**AL* — 7,900 18,400 17,700 43% 2.00 NC 4
FMA5X24**AL* — 7,900 18,400 17,700 43% 2.00 NC 4
PF5MN*A18L* — 8,100 19,000 18,200 43% 1.90 NC 4
PF5MN*B24L* — 8,000 18,700 18,100 43% 1.90 NC 4

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 19 indoor units All 230 certified pairings

Sold as, and units with identical certified values

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Feb 11, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “PH5SAN519**AA* — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/gh5san519_st_staa_st