RHP15060B21 is in the certified data.

Its certified full-speed heating output at 5°F is 30,600–32,800 Btu/h, 53–57% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Evcon and Guardian · central heat pump

RHP15060B21 is in the certified data as of Sep 19, 2026. RHP15060B21 changed its certified EER2 on 2 pairings from 11.7 to 11.0 in the certified data between March 2025 and May 2025.

38 certified pairings with 18 different figures. See all

Certified heating and cooling

Heating at 47°F

57,000

38,500 at 17°F

31,200 at 5°F

Btu/h, certified

2.46 COP at 5°F

Cooling at 95°F

53,500

Btu/h, certified

EER2 11.7 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for RHP15060B21, by outdoor temperature Heating: 31,200 Btu/h at 5°F, 38,500 Btu/h at 17°F, 57,000 Btu/h at 47°F. Cooling: 53,500 Btu/h at 95°F. The bars start at zero. Median of 4.5-ton central models: 40,000 Btu/h at 5°F, 37,800 Btu/h at 17°F, 56,000 Btu/h at 47°F, 55,000 Btu/h at 95°F. 0 20,000 40,000 60,000 Btu/h 31,200 5°F 38,500 17°F 57,000 47°F 53,500 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 57,000 Btu/h of heat at 47°F, 38,500 Btu/h at 17°F, and 31,200 Btu/h at 5°F, 55% of its 47°F rating. It delivers 53,500 Btu/h of cooling at 95°F. At 5°F that is 8,800 Btu/h short of the example heating load of 40,000 Btu/h; at 95°F it is 33,500 Btu/h above the example cooling load of 20,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214799897 · listed by Guardian · certified Jul 7, 2026 · 2 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 31,2009.14 kW −22% 2.46
17°Fone compressor speed 38,50011.28 kW +2% NR
47°Fone compressor speed 57,00016.71 kW +2% NR
95°Fcooling, full load 53,50015.68 kW — NR

EER2 11.7 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.72kW
Electrical input in the 95°F cooling test
4.57kW
Seasonal average heating COP
2.37

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 54,000 Btu heat pumps

4.5-ton central models

This pairing at 5°F
31,200 Btu/h
This unit at 5°F median across its pairings
31,200 Btu/h
Median of 4.5-ton central models at 5°F
40,000 Btu/h
Models in this group
343

This unit is above 22% of them, at number 266 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for RHP15060B21

38 pairings · 38 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for RHP15060B21
This pairingAll pairings
Heating
Heat output at 47°F high stage 57,000 Btu/h 54,500–59,500 Btu/h
Heat output at 17°F full speed 38,500 Btu/h 37,400–38,500 Btu/h
Heat output at 5°F full speed 31,200 Btu/h 30,600–32,800 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 55%
COP at 5°F full speed 2.46 2.22–2.46
HSPF2 Region IV 8.1 7.8–8.1
Cooling
Cooling capacity at 95°F full-load test 53,500 Btu/h 53,000–56,500 Btu/h
EER2 at 95°F 11.7 11.0–12.0
SEER2 cooling season 15.2 15.2–16.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Two-stage
Indoor unit XAFD60JBCN1+JME18D2SN1 16 indoor units
FurnaceNo furnace 5 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified RHP15060B21

Pairings, by indoor-unit class

16 indoor units · 38 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 4 indoor units

  1. XAFD60HBCN1 brand not stated 31,300 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 54,750 Btu/h · 95°F cooling 53,500 Btu/h · Cold output 57% · COP 2.34

  2. XAHC60HBCN1 brand not stated 32,600 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 59,250 Btu/h · 95°F cooling 54,750 Btu/h · Cold output 55% · COP 2.34

  3. XAHD60HBCN1 brand not stated 32,600 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 59,500 Btu/h · 95°F cooling 55,000 Btu/h · Cold output 55% · COP 2.34

  4. XAFC60HBCN1 brand not stated 31,000 Btu/hat 5°F, full speed

    2 pairings, 1 with a furnace · 47°F 54,500 Btu/h · 95°F cooling 53,000 Btu/h · Cold output 57% · COP 2.34

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
XAFD60HBCN1 — 31,300 54,750 53,500 57% 2.34 NC 4
XAHC60HBCN1 — 32,600 59,250 54,750 55% 2.34 NC 4
XAHD60HBCN1 — 32,600 59,500 55,000 55% 2.34 NC 4
XAFC60HBCN1 — 31,000 54,500 53,000 57% 2.34 NC 2

Air handler · 6 indoor units

  1. JHETC60HBCS2N1 brand not stated 30,600 Btu/hat 5°F, full speed

    2 pairings · 47°F 55,000 Btu/h · 95°F cooling 53,500 Btu/h · Cold output 56% · COP 2.22

  2. JHETD60HBCS2N1 brand not stated 30,600 Btu/hat 5°F, full speed

    2 pairings · 47°F 56,000 Btu/h · 95°F cooling 56,000 Btu/h · Cold output 55% · COP 2.26

  3. JHETD60JBCS2N1 brand not stated 30,800 Btu/hat 5°F, full speed

    2 pairings · 47°F 56,000 Btu/h · 95°F cooling 56,000 Btu/h · Cold output 55% · COP 2.24

  4. JHVTC60HBCC2N1 brand not stated 30,800 Btu/hat 5°F, full speed

    2 pairings · 47°F 55,500 Btu/h · 95°F cooling 55,000 Btu/h · Cold output 55% · COP 2.26

  5. JHVTD60HBCC2N1 brand not stated 30,600 Btu/hat 5°F, full speed

    2 pairings · 47°F 56,000 Btu/h · 95°F cooling 56,000 Btu/h · Cold output 55% · COP 2.28

  6. JHVTD60JBCC2N1 brand not stated 30,600 Btu/hat 5°F, full speed

    2 pairings · 47°F 56,500 Btu/h · 95°F cooling 56,500 Btu/h · Cold output 54% · COP 2.22

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
JHETC60HBCS2N1 — 30,600 55,000 53,500 56% 2.22 NC 2
JHETD60HBCS2N1 — 30,600 56,000 56,000 55% 2.26 NC 2
JHETD60JBCS2N1 — 30,800 56,000 56,000 55% 2.24 NC 2
JHVTC60HBCC2N1 — 30,800 55,500 55,000 55% 2.26 NC 2
JHVTD60HBCC2N1 — 30,600 56,000 56,000 55% 2.28 NC 2
JHVTD60JBCC2N1 — 30,600 56,500 56,500 54% 2.22 NC 2

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 16 indoor units All 38 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

Product history

  • RHP15060B21 changed its certified EER2 on 2 pairings from 11.7 to 11.0 in the certified data between March 2025 and May 2025.
  • RHP15060B21 changed its certified COP at 5°F on 2 pairings from 2.36 to 2.32 in the certified data between March 2025 and May 2025.
  • RHP15060B21 changed its certified heat output at 5°F on 2 pairings from 31,200 Btu/h to 31,400 Btu/h in the certified data between March 2025 and May 2025.
  • RHP15060B21 changed its certified heat output at 47°F on 2 pairings from 58,500 Btu/h to 59,000 Btu/h in the certified data between March 2025 and May 2025.
  • RHP15060B21 changed its certified heat output at 17°F on 2 pairings from 38,000 Btu/h to 38,500 Btu/h in the certified data between March 2025 and May 2025.
  • RHP15060B21 was in the certified data by September 2024.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jul 7, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “RHP15060B21 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/rhp15060b21