THF2B60T21 is in the certified data.

Its certified full-speed heating output at 5°F is 29,200–32,800 Btu/h, 50–57% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Champion, Coleman + 3 more · central heat pump

All 48 certified Champion models · All 66 certified Coleman models · All 47 certified Fraser-Johnston models · All 34 certified Johnson Controls models · All 64 certified Luxaire models

THF2B60T21 is in the certified data as of Sep 19, 2026. THF2B60T21 changed its certified EER2 on 5 pairings from 11.7 to 11.0 in the certified data between March 2025 and May 2025.

937 certified pairings with 62 different figures. See all

Certified heating and cooling

Heating at 47°F

59,000

38,000 at 17°F

31,200 at 5°F

Btu/h, certified

2.36 COP at 5°F

Cooling at 95°F

55,500

Btu/h, certified

EER2 11.7 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for THF2B60T21, by outdoor temperature Heating: 31,200 Btu/h at 5°F, 38,000 Btu/h at 17°F, 59,000 Btu/h at 47°F. Cooling: 55,500 Btu/h at 95°F. The bars start at zero. Median of 4.5-ton central models: 40,000 Btu/h at 5°F, 37,800 Btu/h at 17°F, 56,000 Btu/h at 47°F, 55,000 Btu/h at 95°F. 0 20,000 40,000 60,000 Btu/h 31,200 5°F 38,000 17°F 59,000 47°F 55,500 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 59,000 Btu/h of heat at 47°F, 38,000 Btu/h at 17°F, and 31,200 Btu/h at 5°F, 53% of its 47°F rating. It delivers 55,500 Btu/h of cooling at 95°F. At 5°F that is 8,800 Btu/h short of the example heating load of 40,000 Btu/h; at 95°F it is 35,500 Btu/h above the example cooling load of 20,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 212414962 · listed by Coleman · certified Aug 12, 2026 · 70 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 31 programs in 20 states, provinces, or territories:Colorado (1), Idaho (2), Illinois (1), Kansas (1), Maryland (3), Michigan (2), Minnesota (2), Mississippi (1), Nevada (1), New Hampshire (1), New Jersey (4), North Carolina (1), Oregon (2), Pennsylvania (3), South Carolina (1), Texas (3), Utah (1), Washington (2), Wisconsin (1), Newfoundland and Labrador (1).

All 31 programs by state and province

Colorado

Idaho

Illinois

Kansas

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

North Carolina

Oregon

Pennsylvania

South Carolina

Texas

Utah

Washington

Wisconsin

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 31,2009.14 kW −22% 2.36
17°Fone compressor speed 38,00011.14 kW +1% NR
47°Fone compressor speed 59,00017.29 kW +5% NR
95°Fcooling, full load 55,50016.27 kW — NR

EER2 11.7 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.87kW
Electrical input in the 95°F cooling test
4.74kW
Seasonal average heating COP
2.37

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 54,000 Btu heat pumps

4.5-ton central models

This pairing at 5°F
31,200 Btu/h
This unit at 5°F median across its pairings
31,200 Btu/h
Median of 4.5-ton central models at 5°F
40,000 Btu/h
Models in this group
343

This unit is above 22% of them, at number 266 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 54,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 266th of 343; HSPF2, 239th of 358 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • MDPH18060D: The same 57,000 Btu/h rating at 47°F; 51,000 Btu/h at 5°F (this model: 31,200).
  • AC060BXUPCH: The same 57,000 Btu/h rating at 47°F; 48,000 Btu/h at 5°F (this model: 31,200).
  • MDPH180604: The same 57,000 Btu/h rating at 47°F; 45,000 Btu/h at 5°F (this model: 31,200).

Closest models by heat at 5°F

Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 31,200 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42740–1,300
MildTypical16–261,200–1,950
MildTight, well insulated10–181,730–3,120
ColdDrafty, little insulation28–52600–1,110
ColdTypical18–301,040–1,730
ColdTight, well insulated12–221,420–2,600
Very coldDrafty, little insulation32–58540–980
Very coldTypical22–38820–1,420
Very coldTight, well insulated16–281,110–1,950

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for THF2B60T21

937 pairings · 937 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for THF2B60T21
This pairingAll pairings
Heating
Heat output at 47°F high stage 59,000 Btu/h 54,500–59,500 Btu/h
Heat output at 17°F full speed 38,000 Btu/h 37,400–39,000 Btu/h
Heat output at 5°F full speed 31,200 Btu/h 29,200–32,800 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 53%
COP at 5°F full speed 2.36 2.00–2.46
HSPF2 Region IV 8.1 7.8–8.1
Cooling
Cooling capacity at 95°F full-load test 55,500 Btu/h 53,000–57,000 Btu/h
EER2 at 95°F 11.7 11.0–12.0
SEER2 cooling season 15.2 15.2–16.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Two-stage
Indoor unit XAHD60JBCN1 37 indoor units
FurnaceZ8ET120C20LMPS1 37 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On some pairings
Where it is sold US and Canada US and Canada
Model string as certified THF2B60T21

Across 937 certified pairings with 37 indoor models: heat at 5°F 29,200 Btu/h with XAHC60HBCN1 to 32,800 Btu/h with XAHC60HBCN1; HSPF2 7.8 with JHETC60HBCS2N1 to 8.1 with JHETD60HBCS2N1; SEER2 15.2 with JHETC60HBCS2N1 to 16.0 with JHETD60HBCS2N1. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

37 indoor units · 937 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. XAFD60JBCN1 brand not stated 31,400 Btu/hat 5°F, full speed

    132 pairings, 28 with a furnace · 47°F 57,000 Btu/h · 95°F cooling 54,000 Btu/h · Cold output 55% · COP 2.36

  2. XAHD60JBCN1 (the pairing on screen) brand not stated 31,200 Btu/hat 5°F, full speed

    117 pairings, 25 with a furnace · 47°F 58,500 Btu/h · 95°F cooling 55,500 Btu/h · Cold output 53% · COP 2.36

  3. XAFD60JXXN1+TXV brand not stated 31,400 Btu/hat 5°F, full speed

    112 pairings, 24 with a furnace · 47°F 57,000 Btu/h · 95°F cooling 54,000 Btu/h · Cold output 55% · COP 2.38

  4. XAFD60HBCN1 brand not stated 31,400 Btu/hat 5°F, full speed

    92 pairings, 20 with a furnace · 47°F 56,500 Btu/h · 95°F cooling 54,500 Btu/h · Cold output 56% · COP 2.22

  5. XAHD60JXXN1+TXV brand not stated 31,000 Btu/hat 5°F, full speed

    82 pairings, 18 with a furnace · 47°F 58,500 Btu/h · 95°F cooling 55,500 Btu/h · Cold output 53% · COP 2.36

  6. XAFC60HBCN1 brand not stated 31,400 Btu/hat 5°F, full speed

    65 pairings, 13 with a furnace · 47°F 56,000 Btu/h · 95°F cooling 54,000 Btu/h · Cold output 56% · COP 2.32

  7. XAHC60HBCN1 brand not stated 30,800 Btu/hat 5°F, full speed

    65 pairings, 13 with a furnace · 47°F 58,000 Btu/h · 95°F cooling 54,500 Btu/h · Cold output 53% · COP 2.02

  8. XAFD60HXXN1+TXV brand not stated 31,400 Btu/hat 5°F, full speed

    52 pairings, 12 with a furnace · 47°F 56,500 Btu/h · 95°F cooling 54,500 Btu/h · Cold output 56% · COP 2.22

  9. XAHD60HBCN1 brand not stated 32,600 Btu/hat 5°F, full speed

    35 pairings, 7 with a furnace · 47°F 59,500 Btu/h · 95°F cooling 55,000 Btu/h · Cold output 55% · COP 2.34

  10. XAFC60HXXN1+TXV brand not stated 31,300 Btu/hat 5°F, full speed

    30 pairings, 6 with a furnace · 47°F 56,000 Btu/h · 95°F cooling 54,000 Btu/h · Cold output 56% · COP 2.26

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
XAFD60JBCN1 — 31,400 57,000 54,000 55% 2.36 NC 132
XAHD60JBCN1 (the pairing on screen) — 31,200 58,500 55,500 53% 2.36 NC 117
XAFD60JXXN1+TXV — 31,400 57,000 54,000 55% 2.38 NC 112
XAFD60HBCN1 — 31,400 56,500 54,500 56% 2.22 NC 92
XAHD60JXXN1+TXV — 31,000 58,500 55,500 53% 2.36 NC 82
XAFC60HBCN1 — 31,400 56,000 54,000 56% 2.32 NC 65
XAHC60HBCN1 — 30,800 58,000 54,500 53% 2.02 NC 65
XAFD60HXXN1+TXV — 31,400 56,500 54,500 56% 2.22 NC 52
XAHD60HBCN1 — 32,600 59,500 55,000 55% 2.34 NC 35
XAFC60HXXN1+TXV — 31,300 56,000 54,000 56% 2.26 NC 30

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 37 indoor units All 937 certified pairings

Sold as, and units with identical certified values

Product history

  • THF2B60T21 changed its certified EER2 on 5 pairings from 11.7 to 11.0 in the certified data between March 2025 and May 2025.
  • THF2B60T21 changed its certified COP at 5°F on 5 pairings from 2.36 to 2.32 in the certified data between March 2025 and May 2025.
  • THF2B60T21 changed its certified heat output at 5°F on 5 pairings from 31,200 Btu/h to 31,400 Btu/h in the certified data between March 2025 and May 2025.
  • THF2B60T21 changed its certified heat output at 47°F on 5 pairings from 58,500 Btu/h to 59,000 Btu/h in the certified data between March 2025 and May 2025.
  • THF2B60T21 changed its certified heat output at 17°F on 5 pairings from 38,000 Btu/h to 38,500 Btu/h in the certified data between March 2025 and May 2025.
  • THF2B60T21 was in the certified data by September 2024.

History and definitions

Other LX SERIES models by nominal cooling size: THF2B18S21 (18,000 Btu), HH824E2S11 (24,000 Btu), HH824E2S12 (24,000 Btu), PHE6A2424 (24,000 Btu), PHG6A240752X4 (24,000 Btu), THF2B24T21 (24,000 Btu), HH836E2S12 (30,000 Btu), THF2B30T21 (30,000 Btu); more models from this brand.

Other LX SERIES models by nominal cooling size: THF2B18S21 (18,000 Btu), HH824E2S11 (24,000 Btu), PHE6A2424 (24,000 Btu), PHG6A240752X4 (24,000 Btu), THF2B24T21 (24,000 Btu), THF2B30T21 (30,000 Btu), HH836E2S11 (36,000 Btu), PHE6B3624 (36,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Aug 12, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “THF2B60T21 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/thf2b60t21