THF2B24T21
THF2B24T21 is in the certified data.
Its certified full-speed heating output at 5°F is 9,600–12,000 Btu/h2.81–3.52 kW, 43–54% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Champion, Coleman + 3 more · central heat pump
THF2B24T21 is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
22,2006.51NR
No 47°F rating for this pairing.
14,2004.16NR at 17°F
11,0003.22NR at 5°F
Btu/hkW, certified
2.10NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 22,200 Btu/h6.51 kW of heat at 47°F, 14,200 Btu/h4.16 kW at 17°F, and 11,000 Btu/h3.22 kW at 5°F, 50% of its 47°F rating. It delivers 23,400 Btu/h6.86 kW of cooling at 95°F. At 5°F that is 8,000 Btu/h2.34 kW short of the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 13,900 Btu/h4.07 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210352659 · listed by Coleman · certified Jul 7, 2026 · 29 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 11,0003.22 kW | −42% | 2.10 | |
| 17°Fone compressor speed | 14,2004.16 kW | −26% | NR | |
| 47°Fone compressor speed | 22,2006.51 kW | −8% | NR | |
| 95°Fcooling, full load | 23,4006.86 kW | — | NR |
EER2 11.7 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.54kW
- Electrical input in the 95°F cooling test
- 2.00kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton central models
- This pairing at 5°F
- 11,000 Btu/h3.22 kWNR
- This unit at 5°F median across its pairings
- 11,000 Btu/h3.22 kW
- Median of 2-ton central models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 565
This unit is above 5% of them, at number 535 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.
Closest models by heat at 5°F
- GSZC702410AGoodman · 11,000 Btu/h
- HSA1424S1-**ACentury and Comfort-Aire · 11,000 Btu/h
- SH4BF5M2SX24KNordyne and Nortek · 11,000 Btu/h
- W5H8T24*K*AAA*EcoTemp and Grandaire · 11,000 Btu/h
- YZT24B21York · 11,000 Btu/h
- 5DCZ5024A1American Standard and Trane · 10,900 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for THF2B24T21
837 pairings · 837 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 22,200 Btu/h6.51 kWNR | 20,600–22,800 Btu/h6.04–6.68 kW |
| Heat output at 17°F full speed | 14,200 Btu/h4.16 kWNR | 13,100–14,500 Btu/h3.84–4.25 kW |
| Heat output at 5°F full speed | 11,000 Btu/h3.22 kWNR | 9,600–12,000 Btu/h2.81–3.52 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 50%NR | |
| COP at 5°F full speed | 2.10NR | 1.96–2.30 |
| HSPF2 Region IV | 7.8NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 23,400 Btu/h6.86 kWNR | 22,800–24,200 Btu/h6.68–7.09 kW |
| EER2 at 95°F | 11.7NR | 11.7–12.0 |
| SEER2 cooling season | 15.2NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | XAHB30CBAN1 | 26 indoor units |
| Furnace | TM8Y080B12MP11 | 44 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | THF2B24T21 | |
Pairings, by indoor-unit class
26 indoor units · 837 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 9 indoor units
-
XAFB30CBAN1 (the pairing on screen) brand not stated 10,800 Btu/h3.17 kWat 5°F, full speed
-
XAHB30CBAN1 (the pairing on screen) brand not stated 11,100 Btu/h3.25 kWat 5°F, full speed
-
XAHC36DBAN1 (the pairing on screen) brand not stated 11,000 Btu/h3.22 kWat 5°F, full speed
-
XAFB36DBAN1 (the pairing on screen) brand not stated 11,100 Btu/h3.25 kWat 5°F, full speed
-
XAFC30CBAN1 (the pairing on screen) brand not stated 10,700 Btu/h3.14 kWat 5°F, full speed
-
XAHC30CBAN1 (the pairing on screen) brand not stated 11,000 Btu/h3.22 kWat 5°F, full speed
-
XAFB36DXXN1+TXV (the pairing on screen) brand not stated 11,300 Btu/h3.31 kWat 5°F, full speed
-
XAHB36DBAN1 (the pairing on screen) brand not stated 11,400 Btu/h3.34 kWat 5°F, full speed
-
XAFA30DBAN1 (the pairing on screen) brand not stated 11,100 Btu/h3.25 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| XAFB30CBAN1 (the pairing on screen) | — | 10,8003.17 | 22,2006.51 | 23,8006.98 | 48% | 2.04 | NC | 139 |
| XAHB30CBAN1 (the pairing on screen) | — | 11,1003.25 | 22,2006.51 | 23,4006.86 | 50% | 2.10 | NC | 112 |
| XAHC36DBAN1 (the pairing on screen) | — | 11,0003.22 | 21,2006.21 | 24,0007.03 | 52% | 2.18 | NC | 97 |
| XAFB36DBAN1 (the pairing on screen) | — | 11,1003.25 | 22,2006.51 | 23,8006.98 | 51% | 2.22 | NC | 95 |
| XAFC30CBAN1 (the pairing on screen) | — | 10,7003.14 | 22,2006.51 | 23,6006.92 | 48% | 2.04 | NC | 82 |
| XAHC30CBAN1 (the pairing on screen) | — | 11,0003.22 | 22,2006.51 | 23,4006.86 | 50% | 2.10 | NC | 82 |
| XAFB36DXXN1+TXV (the pairing on screen) | — | 11,3003.31 | 22,2006.51 | 24,0007.03 | 51% | 2.24 | NC | 65 |
| XAHB36DBAN1 (the pairing on screen) | — | 11,4003.34 | 21,2006.21 | 24,0007.03 | 54% | 2.26 | NC | 65 |
| XAFA30DBAN1 (the pairing on screen) | — | 11,1003.25 | 21,4006.27 | 23,2006.80 | 52% | 2.22 | NC | 15 |
Air handler · 1 indoor unit
-
JHETB24CBAS2N1 (the pairing on screen) brand not stated 11,600 Btu/h3.40 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| JHETB24CBAS2N1 (the pairing on screen) | — | 11,6003.40 | 21,6006.33 | 23,6006.92 | 54% | 2.26 | NC | 5 |
Sold as, and units with identical certified values
Brands listing this model number
- Champion165 pairings
- Coleman171 pairings
- Fraser-Johnston165 pairings
- Johnson Controls165 pairings
- Luxaire171 pairings
Other brands that list these model numbers
- Are Champion and Luxaire heat pumps the same?48 shared model numbers
- Are Champion and Fraser-Johnston heat pumps the same?47 shared model numbers
- Are Champion and Coleman heat pumps the same?44 shared model numbers
- Are Champion and Johnson Controls heat pumps the same?34 shared model numbers
- Are Coleman and Luxaire heat pumps the same?60 shared model numbers
- Are Coleman and Fraser-Johnston heat pumps the same?43 shared model numbers
Model number as listed
- THF2B24T21 837 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 7, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read