Heat Pump List

Tools

HH836E2S12

HH836E2S12 is in the certified data.

Its certified full-speed heating output at 5°F is 26,800–28,200 Btu/h, 79–85% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Champion, Coleman + 4 more · central heat pump

All 48 certified Champion models · All 66 certified Coleman models · All 47 certified Fraser-Johnston models · All 179 certified Kenmore models · All 64 certified Luxaire models · All 105 certified York models

HH836E2S12 is in the certified data as of Oct 18, 2026.

3,583 certified pairings with 138 different figures. See all

Certified heating and cooling

Heating at 47°F

32,200

33,600 at 17°F

27,400 at 5°F

Btu/h, certified

2.20 COP at 5°F

Cooling at 95°F

31,400

Btu/h, certified

EER2 11.0 at 95°F

SEER2 16.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for HH836E2S12, by outdoor temperature Heating: 27,400 Btu/h at 5°F, 33,600 Btu/h at 17°F, 32,200 Btu/h at 47°F. Cooling: 31,400 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton central models: 22,400 Btu/h at 5°F, 20,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 27,400 5°F 33,600 17°F 32,200 47°F 31,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 32,200 Btu/h of heat at 47°F, 33,600 Btu/h at 17°F, and 27,400 Btu/h at 5°F, 85% of its 47°F rating. It delivers 31,400 Btu/h of cooling at 95°F. At 5°F that is 4,900 Btu/h above the example heating load of 22,500 Btu/h; at 95°F it is 19,900 Btu/h above the example cooling load of 11,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218688380 · listed by York · certified Oct 16, 2026 · 75 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 36 programs in 24 states, provinces, or territories:California (2), Colorado (1), Connecticut (3), Idaho (2), Illinois (1), Kansas (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (1), Nevada (1), New Hampshire (3), North Carolina (1), Oregon (2), Pennsylvania (2), Rhode Island (1), South Carolina (1), Texas (2), Utah (1), Washington (3), Wisconsin (1), British Columbia (1), Newfoundland and Labrador (1).

All 36 programs by state and province

California

Colorado

Connecticut

Idaho

Illinois

Kansas

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

North Carolina

Oregon

Pennsylvania

Rhode Island

South Carolina

Texas

Utah

Washington

Wisconsin

British Columbia

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 27,4008.03 kW +22% 2.20
17°Ffull speed 33,6009.85 kW +63% NR
47°Fhigh stage 32,2009.44 kW +7% NR
95°Fcooling, full load 31,4009.20 kW — NR

EER2 11.0 in that test. SEER2 16.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.65kW
Electrical input in the 95°F cooling test
2.85kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Oct 18, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton central models

This pairing at 5°F
27,400 Btu/h
This unit at 5°F median across its pairings
27,400 Btu/h
Median of 2.5-ton central models at 5°F
22,400 Btu/h
Models in this group
288

This unit is above 70% of them, at number 86 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 30,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 90th of 288; HSPF2, 154th of 290 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • BMSAH30HHC: The same 33,000 Btu/h rating at 47°F; 32,600 Btu/h at 5°F (this model: 27,400).
  • AHU30HPV1BO: The same 33,000 Btu/h rating at 47°F; 32,200 Btu/h at 5°F (this model: 27,400).
  • 38MURAQ30AB3: The same 33,000 Btu/h rating at 47°F; 24,000 Btu/h at 5°F (this model: 27,400).

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 27,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42650–1,140
MildTypical16–261,050–1,710
MildTight, well insulated10–181,520–2,740
ColdDrafty, little insulation28–52530–980
ColdTypical18–30910–1,520
ColdTight, well insulated12–221,250–2,280
Very coldDrafty, little insulation32–58470–860
Very coldTypical22–38720–1,250
Very coldTight, well insulated16–28980–1,710

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for HH836E2S12

3,583 pairings · 3,583 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for HH836E2S12
This pairingAll pairings
Heating
Heat output at 47°F high stage 32,200 Btu/h 32,000–34,000 Btu/h
Heat output at 17°F full speed 33,600 Btu/h 32,600–34,200 Btu/h
Heat output at 5°F full speed 27,400 Btu/h 26,800–28,200 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 85%
COP at 5°F full speed 2.20 2.18–2.38
HSPF2 Region IV 8.5 8.5
Cooling
Cooling capacity at 95°F full-load test 31,400 Btu/h 31,200–34,000 Btu/h
EER2 at 95°F 11.0 10.0–11.7
SEER2 cooling season 16.5 16.0–18.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Two-stage
Indoor unit CTM36B5CDS2 51 indoor units
FurnaceTM9V080B12MP12 166 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified HH836E2S12

Across 3,583 certified pairings with 51 indoor models: heat at 5°F 26,800 Btu/h with CTF48C5CFS1 to 28,200 Btu/h with CTF36B5CDS1; HSPF2 8.5 throughout; SEER2 16.0 with CTF48C5CFS1 to 18.0 with CTF36C5CDS1. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

51 indoor units · 3,583 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. CTF48C5CFS2 brand not stated 27,000 Btu/hat 5°F, full speed

    303 pairings, 119 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 82% · COP 2.32

  2. CTU48C5XFS2+TXV brand not stated 27,000 Btu/hat 5°F, full speed

    303 pairings, 119 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 82% · COP 2.32

  3. CTM36C5CDS2 brand not stated 27,800 Btu/hat 5°F, full speed

    297 pairings, 116 with a furnace · 47°F 33,800 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 83% · COP 2.26

  4. CTM48C5CFS2 brand not stated 27,000 Btu/hat 5°F, full speed

    297 pairings, 116 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 82% · COP 2.32

  5. CTF36C5CDS2 brand not stated 27,600 Btu/hat 5°F, full speed

    281 pairings, 111 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 84% · COP 2.28

  6. CTF48C5CFS1 brand not stated 27,000 Btu/hat 5°F, full speed

    264 pairings, 104 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 33,200 Btu/h · Cold output 82% · COP 2.32

  7. CTU48C5XFS1+TXV brand not stated 27,000 Btu/hat 5°F, full speed

    264 pairings, 104 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 33,200 Btu/h · Cold output 82% · COP 2.32

  8. CTM36C5CDS1 brand not stated 27,800 Btu/hat 5°F, full speed

    258 pairings, 101 with a furnace · 47°F 34,000 Btu/h · 95°F cooling 33,400 Btu/h · Cold output 82% · COP 2.28

  9. CTM48C5CFS1 brand not stated 27,000 Btu/hat 5°F, full speed

    258 pairings, 101 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 33,200 Btu/h · Cold output 81% · COP 2.32

  10. CTF36C5CDS1 brand not stated 27,800 Btu/hat 5°F, full speed

    242 pairings, 96 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 33,400 Btu/h · Cold output 84% · COP 2.28

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CTF48C5CFS2 — 27,000 33,000 33,000 82% 2.32 Yes 303
CTU48C5XFS2+TXV — 27,000 33,000 33,000 82% 2.32 Yes 303
CTM36C5CDS2 — 27,800 33,800 33,000 83% 2.26 Yes 297
CTM48C5CFS2 — 27,000 33,000 33,000 82% 2.32 Yes 297
CTF36C5CDS2 — 27,600 33,000 33,000 84% 2.28 Yes 281
CTF48C5CFS1 — 27,000 33,000 33,200 82% 2.32 Yes 264
CTU48C5XFS1+TXV — 27,000 33,000 33,200 82% 2.32 Yes 264
CTM36C5CDS1 — 27,800 34,000 33,400 82% 2.28 Yes 258
CTM48C5CFS1 — 27,000 33,000 33,200 81% 2.32 Yes 258
CTF36C5CDS1 — 27,800 33,000 33,400 84% 2.28 Yes 242

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 51 indoor units All 3,583 certified pairings

Sold as, and units with identical certified values

History and definitions

Other LX SERIES models by nominal cooling size: THF2B18S21 (18,000 Btu), HH824E2S11 (24,000 Btu), HH824E2S12 (24,000 Btu), PHE6A2424 (24,000 Btu), PHG6A240752X4 (24,000 Btu), THF2B24T21 (24,000 Btu), THF2B30T21 (30,000 Btu), HH836E2S11 (36,000 Btu); more models from this brand.

Other LX SERIES models by nominal cooling size: HH824E2S11 (24,000 Btu), HH824E2S12 (24,000 Btu), HH836E2S11 (36,000 Btu), HH860E2S11 (42,000 Btu), HH860E2S12 (42,000 Btu).

Other LX SERIES models by nominal cooling size: YH2F18SB21 (18,000 Btu), YH518E2S11 (18,000 Btu), YH618E2S11 (18,000 Btu), HH824E2S11 (24,000 Btu), HH824E2S12 (24,000 Btu), PHE6A2424 (24,000 Btu), YH2F24TB21 (24,000 Btu), YH524E2S11 (24,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Oct 16, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “HH836E2S12 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/hh836e2s12