Heat Pump List

Tools

AC060BXUPCH

AC060BXUPCH is in the certified data.

Its certified full-speed heating output at 5°F is 48,000 Btu/h, 84% of its 47°F rating (tests at different compressor speeds) across its certified pairings.

Samsung · central heat pump

AC060BXUPCH is in the certified data as of Sep 19, 2026. AC060BXUPCH changed its certified heat output at 47°F on AHRI certificate 211133470 from 53,000 Btu/h to 57,000 Btu/h in the certified data between March 2025 and May 2025.

Certified heating and cooling

Heating at 47°F

57,000

54,000 at 17°F

48,000 at 5°F

Btu/h, certified

1.80 COP at 5°F

Cooling at 95°F

57,000

Btu/h, certified

EER2 8.5 at 95°F

SEER2 17.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for AC060BXUPCH, by outdoor temperature Heating: 48,000 Btu/h at 5°F, 54,000 Btu/h at 17°F, 57,000 Btu/h at 47°F. Cooling: 57,000 Btu/h at 95°F. The bars start at zero. Median of 4.5-ton central models: 40,000 Btu/h at 5°F, 37,800 Btu/h at 17°F, 56,000 Btu/h at 47°F, 55,000 Btu/h at 95°F. 0 20,000 40,000 60,000 Btu/h 48,000 5°F 54,000 17°F 57,000 47°F 57,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 57,000 Btu/h of heat at 47°F, 54,000 Btu/h at 17°F, and 48,000 Btu/h at 5°F, 84% of its 47°F rating. It delivers 57,000 Btu/h of cooling at 95°F. At 5°F that is 8,000 Btu/h above the example heating load of 40,000 Btu/h; at 95°F it is 37,000 Btu/h above the example cooling load of 20,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 210273925 · listed by Samsung · certified Mar 20, 2025 · 2 pairings on 2 certificates share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 48,00014.07 kW +20% 1.80
17°Ffull speed 54,00015.83 kW +43% NR
47°Fnormal speed 57,00016.71 kW +2% NR
95°Fcooling, full load 57,00016.71 kW — NR

EER2 8.5 in that test. SEER2 17.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
7.82kW
Electrical input in the 95°F cooling test
6.71kW
Seasonal average heating COP
2.64

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 54,000 Btu heat pumps

4.5-ton central models

This pairing at 5°F
48,000 Btu/h
This unit at 5°F median across its pairings
48,000 Btu/h
Median of 4.5-ton central models at 5°F
40,000 Btu/h
Models in this group
343

This unit is above 81% of them, at number 65 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for AC060BXUPCH

2 pairings · 2 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for AC060BXUPCH
This pairingAll pairings
Heating
Heat output at 47°F normal speed 57,000 Btu/h 57,000 Btu/h
Heat output at 17°F full speed 54,000 Btu/h 54,000 Btu/h
Heat output at 5°F full speed 48,000 Btu/h 48,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 84%
COP at 5°F full speed 1.80 1.80
HSPF2 Region IV 9.0 9.0
Cooling
Cooling capacity at 95°F full-load test 57,000 Btu/h 57,000 Btu/h
EER2 at 95°F 8.5 8.5
SEER2 cooling season 17.5 17.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit AV600CT 2 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified AC060BXUPCH

Pairings, by indoor-unit class

2 indoor units · 2 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 2 indoor units

  1. AV600CT (the pairing on screen) brand not stated 48,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 57,000 Btu/h · 95°F cooling 57,000 Btu/h · Cold output 84% · COP 1.80

  2. BVRMC7960 brand not stated 48,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 57,000 Btu/h · 95°F cooling 57,000 Btu/h · Cold output 84% · COP 1.80

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
AV600CT (the pairing on screen) — 48,000 57,000 57,000 84% 1.80 Yes 1
BVRMC7960 — 48,000 57,000 57,000 84% 1.80 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • AC060BXUPCH changed its certified heat output at 47°F on AHRI certificate 211133470 from 53,000 Btu/h to 57,000 Btu/h in the certified data between March 2025 and May 2025.
  • AC060BXUPCH changed its certified heat output at 47°F on AHRI certificate 210273925 from 53,000 Btu/h to 57,000 Btu/h in the certified data between February 2025 and March 2025.
  • AC060BXUPCH was in the certified data by September 2024.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Mar 20, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “AC060BXUPCH — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/ac060bxupch