Heat Pump List

Tools

RP15AZ24AJ2N

RP15AZ24AJ2N is in the certified data.

Its certified full-speed heating output at 5°F is 11,500–19,400 Btu/h, 51–63% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Rheem and Ruud · central heat pump

RP15AZ24AJ2N is in the certified data as of Sep 19, 2026.

48 certified pairings with 18 different figures. See all

Certified heating and cooling

Heating at 47°F

22,800

15,600 at 17°F

12,300 at 5°F

Btu/h, certified

2.30 COP at 5°F

Cooling at 95°F

22,800

Btu/h, certified

EER2 11.7 at 95°F

SEER2 16.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for RP15AZ24AJ2N, by outdoor temperature Heating: 12,300 Btu/h at 5°F, 15,600 Btu/h at 17°F, 22,800 Btu/h at 47°F. Cooling: 22,800 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 12,300 5°F 15,600 17°F 22,800 47°F 22,800 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 22,800 Btu/h of heat at 47°F, 15,600 Btu/h at 17°F, and 12,300 Btu/h at 5°F, 54% of its 47°F rating. It delivers 22,800 Btu/h of cooling at 95°F. At 5°F that is 6,700 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 13,300 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 212381137 · listed by Ruud · certified Jun 3, 2026 · 2 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 12,3003.60 kW −35% 2.30
17°Fone compressor speed 15,6004.57 kW −19% NR
47°Fone compressor speed 22,8006.68 kW −5% NR
95°Fcooling, full load 22,8006.68 kW — NR

EER2 11.7 in that test. SEER2 16.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.57kW
Electrical input in the 95°F cooling test
1.95kW
Seasonal average heating COP
2.37

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
12,300 Btu/h
This unit at 5°F median across its pairings
12,300 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 18% of them, at number 466 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for RP15AZ24AJ2N

48 pairings · 48 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for RP15AZ24AJ2N
This pairingAll pairings
Heating
Heat output at 47°F high stage 22,800 Btu/h 18,500–34,200 Btu/h
Heat output at 17°F full speed 15,600 Btu/h 13,600–24,400 Btu/h
Heat output at 5°F full speed 12,300 Btu/h 11,500–19,400 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 54%
COP at 5°F full speed 2.30 2.00–2.30
HSPF2 Region IV 8.1 7.8–8.1
Cooling
Cooling capacity at 95°F full-load test 22,800 Btu/h 22,800–34,200 Btu/h
EER2 at 95°F 11.7 11.7
SEER2 cooling season 16.0 15.2–16.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Two-stage
Indoor unit RH2VZ2417STANN 8 indoor units
FurnaceNo furnace 22 furnaces
Cold-climate designation EPA's designation, as published Yes On some pairings
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified RP15AZ24AJ2N

Pairings, by indoor-unit class

8 indoor units · 48 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 3 indoor units

  1. RCFZ2417STANM brand not stated 12,600 Btu/hat 5°F, full speed

    30 pairings, 22 with a furnace · 47°F 22,800 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 55% · COP 2.20

  2. RCFZ2417MTANM brand not stated 12,000 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 22,800 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 53% · COP 2.00

  3. RCFZ2421MTANM brand not stated 11,850 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 22,800 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 52% · COP 2.10

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RCFZ2417STANM — 12,600 22,800 22,800 55% 2.20 Yes 30
RCFZ2417MTANM — 12,000 22,800 22,800 53% 2.00 NC 4
RCFZ2421MTANM — 11,850 22,800 22,800 52% 2.10 NC 4

Air handler · 5 indoor units

  1. RF2TZ2421STANS brand not stated 11,600 Btu/hat 5°F, full speed

    2 pairings · 47°F 18,500 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 63% · COP 2.10

  2. RH2TZ2417STANN brand not stated 12,050 Btu/hat 5°F, full speed

    2 pairings · 47°F 22,600 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 53% · COP 2.25

  3. RH2VZ2417STANN (the pairing on screen) brand not stated 12,300 Btu/hat 5°F, full speed

    2 pairings · 47°F 22,800 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 54% · COP 2.30

  4. RH3VZ2417STACN brand not stated 11,500 Btu/hat 5°F, full speed

    2 pairings · 47°F 22,600 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 51% · COP 2.10

  5. WH2TZ2417STANN brand not stated 19,400 Btu/hat 5°F, full speed

    2 pairings · 47°F 34,200 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 57% · COP 2.30

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RF2TZ2421STANS — 11,600 18,500 22,800 63% 2.10 NC 2
RH2TZ2417STANN — 12,050 22,600 22,800 53% 2.25 NC 2
RH2VZ2417STANN (the pairing on screen) — 12,300 22,800 22,800 54% 2.30 Yes 2
RH3VZ2417STACN — 11,500 22,600 22,800 51% 2.10 NC 2
WH2TZ2417STANN — 19,400 34,200 34,200 57% 2.30 NC 2

The share is heat output at 5°F divided by the 47°F rating.

Showing 8 of 8 indoor units All 48 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jun 3, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “RP15AZ24AJ2N — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/rp15az24aj2n