RP18AZ24AJVC is in the certified data.

Its certified full-speed heating output at 5°F is 24,800–26,200 Btu/h, 103–109% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Rheem · central heat pump

RP18AZ24AJVC is in the certified data as of Sep 19, 2026. RP18AZ24AJVC changed its certified heat output at 47°F on 27 pairings from 22,800 Btu/h to 24,000 Btu/h in the certified data between February 2025 and March 2025.

14 certified pairings with 4 different figures. See all

Certified heating and cooling

Heating at 47°F

24,000

25,400 at 17°F

26,000 at 5°F

Btu/h, certified

2.10 COP at 5°F

Cooling at 95°F

22,800

Btu/h, certified

EER2 12.5 at 95°F

SEER2 20.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for RP18AZ24AJVC, by outdoor temperature Heating: 26,000 Btu/h at 5°F, 25,400 Btu/h at 17°F, 24,000 Btu/h at 47°F. Cooling: 22,800 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 10,000 20,000 30,000 Btu/h 26,000 5°F 25,400 17°F 24,000 47°F 22,800 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 24,000 Btu/h of heat at 47°F, 25,400 Btu/h at 17°F, and 26,000 Btu/h at 5°F, 108% of its 47°F rating. It delivers 22,800 Btu/h of cooling at 95°F. At 5°F that is 7,000 Btu/h above the example heating load of 19,000 Btu/h; at 95°F it is 13,300 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 209872685 · listed by Rheem · certified Jun 3, 2026 · 11 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 26,0007.62 kW +37% 2.10
17°Ffull speed 25,4007.44 kW +32% NR
47°Fnormal speed 24,0007.03 kW 0% NR
95°Fcooling, full load 22,8006.68 kW — NR

EER2 12.5 in that test. SEER2 20.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.63kW
Electrical input in the 95°F cooling test
1.82kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
26,000 Btu/h
This unit at 5°F median across its pairings
26,000 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 98% of them, at number 13 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for RP18AZ24AJVC

14 pairings · 14 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for RP18AZ24AJVC
This pairingAll pairings
Heating
Heat output at 47°F normal speed 24,000 Btu/h 24,000 Btu/h
Heat output at 17°F full speed 25,400 Btu/h 24,200–25,600 Btu/h
Heat output at 5°F full speed 26,000 Btu/h 24,800–26,200 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 108%
COP at 5°F full speed 2.10 2.00–2.10
HSPF2 Region IV 8.5 8.5
Cooling
Cooling capacity at 95°F full-load test 22,800 Btu/h 22,800 Btu/h
EER2 at 95°F 12.5 12.5
SEER2 cooling season 20.0 19.0–20.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit RCFZ2421HEAAM 2 indoor units
FurnaceR962V0403A17M4S 13 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold United States US and Canada
Model string as certified RP18AZ24AJVC

Pairings, by indoor-unit class

2 indoor units · 14 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 1 indoor unit

  1. RCFZ2421HEAAM (the pairing on screen) brand not stated 26,000 Btu/hat 5°F, full speed

    13 pairings, 13 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 108% · COP 2.10

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RCFZ2421HEAAM (the pairing on screen) — 26,000 24,000 22,800 108% 2.10 Yes 13

Air handler · 1 indoor unit

  1. RHMVZ2421HEACA brand not stated 24,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 24,000 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 103% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RHMVZ2421HEACA — 24,800 24,000 22,800 103% 2.00 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • RP18AZ24AJVC changed its certified heat output at 47°F on 27 pairings from 22,800 Btu/h to 24,000 Btu/h in the certified data between February 2025 and March 2025.
  • RP18AZ24AJVC was in the certified data by September 2024.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jun 3, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “RP18AZ24AJVC — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/rp18az24ajvc