YH2F48TB21
YH2F48TB21 is in the certified data.
Its certified full-speed heating output at 5°F is 23,400–29,800 Btu/h6.86–8.73 kW, 53–66% of its 47°F rating, depending on the pairing.
York · central heat pump
YH2F48TB21 is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
44,50013.04NR
No 47°F rating for this pairing.
30,6008.97NR at 17°F
25,0007.33NR at 5°F
Btu/hkW, certified
2.46NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 44,500 Btu/h13.04 kW of heat at 47°F, 30,600 Btu/h8.97 kW at 17°F, and 25,000 Btu/h7.33 kW at 5°F, 56% of its 47°F rating. It delivers 46,000 Btu/h13.48 kW of cooling at 95°F. At 5°F that is 11,500 Btu/h3.37 kW short of the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 28,000 Btu/h8.21 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210337897 · listed by York · certified Jul 7, 2026 · 10 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 25,0007.33 kW | −31% | 2.46 | |
| 17°Fone compressor speed | 30,6008.97 kW | −13% | NR | |
| 47°Fone compressor speed | 44,50013.04 kW | −7% | NR | |
| 95°Fcooling, full load | 46,00013.48 kW | — | NR |
EER2 11.7 in that test. SEER2 16.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.98kW
- Electrical input in the 95°F cooling test
- 3.93kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 25,000 Btu/h7.33 kWNR
- This unit at 5°F median across its pairings
- 25,000 Btu/h7.33 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 21% of them, at number 323 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- PH8TAN548**AB*WeatherMaker · 25,000 Btu/h
- SH4BF5M2SX48KNordyne and Nortek · 25,000 Btu/h
- W5H8T48*K*AAA*EcoTemp and Grandaire · 25,000 Btu/h
- C5H8T48*K*AAA*Comfortmaker, Day & Night + 1 more · 24,800 Btu/h
- NS22H48MA4-**AGE · 24,600 Btu/h
- GH5SAN548**AA*Bryant and Carrier · 24,400 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YH2F48TB21
327 pairings · 327 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 44,500 Btu/h13.04 kWNR | 43,500–48,000 Btu/h12.75–14.07 kW |
| Heat output at 17°F full speed | 30,600 Btu/h8.97 kWNR | 29,200–34,200 Btu/h8.56–10.02 kW |
| Heat output at 5°F full speed | 25,000 Btu/h7.33 kWNR | 23,400–29,800 Btu/h6.86–8.73 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 56%NR | |
| COP at 5°F full speed | 2.46NR | 2.20–2.84 |
| HSPF2 Region IV | 8.1NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 46,000 Btu/h13.48 kWNR | 44,500–47,500 Btu/h13.04–13.92 kW |
| EER2 at 95°F | 11.7NR | 10.5–12.0 |
| SEER2 cooling season | 16.0NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | XAHC60HBCN1 | 34 indoor units |
| Furnace | TM8V100C20MP12 | 90 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YH2F48TB21 | |
Pairings, by indoor-unit class
34 indoor units · 327 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 9 indoor units
-
XAHC60HBCN1 (the pairing on screen) brand not stated 25,000 Btu/h7.33 kWat 5°F, full speed
-
XAHD60HBCN1 (the pairing on screen) brand not stated 25,000 Btu/h7.33 kWat 5°F, full speed
-
XAFC60HBCN1 (the pairing on screen) brand not stated 23,800 Btu/h6.98 kWat 5°F, full speed
-
XAFD60HBCN1 (the pairing on screen) brand not stated 23,800 Btu/h6.98 kWat 5°F, full speed
-
XAHC60GBCN1 (the pairing on screen) brand not stated 24,200 Btu/h7.09 kWat 5°F, full speed
-
XAFC60GBCN1 (the pairing on screen) brand not stated 26,400 Btu/h7.74 kWat 5°F, full speed
-
XAFD60GBCN1 (the pairing on screen) brand not stated 26,400 Btu/h7.74 kWat 5°F, full speed
-
XAFD60GXXN1+TXV (the pairing on screen) brand not stated 26,400 Btu/h7.74 kWat 5°F, full speed
-
XAHD60GBCN1 (the pairing on screen) brand not stated 24,000 Btu/h7.03 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| XAHC60HBCN1 (the pairing on screen) | — | 25,0007.33 | 44,00012.90 | 45,50013.33 | 56% | 2.46 | NC | 70 |
| XAHD60HBCN1 (the pairing on screen) | — | 25,0007.33 | 44,50013.04 | 46,00013.48 | 56% | 2.46 | NC | 55 |
| XAFC60HBCN1 (the pairing on screen) | — | 23,8006.98 | 43,50012.75 | 45,50013.33 | 54% | 2.28 | NC | 32 |
| XAFD60HBCN1 (the pairing on screen) | — | 23,8006.98 | 43,50012.75 | 45,50013.33 | 54% | 2.28 | NC | 31 |
| XAHC60GBCN1 (the pairing on screen) | — | 24,2007.09 | 45,00013.19 | 46,00013.48 | 54% | 2.26 | NC | 27 |
| XAFC60GBCN1 (the pairing on screen) | — | 26,4007.74 | 47,50013.92 | 45,50013.33 | 56% | 2.40 | NC | 23 |
| XAFD60GBCN1 (the pairing on screen) | — | 26,4007.74 | 47,50013.92 | 45,50013.33 | 56% | 2.40 | NC | 22 |
| XAFD60GXXN1+TXV (the pairing on screen) | — | 26,4007.74 | 47,50013.92 | 45,50013.33 | 56% | 2.40 | NC | 22 |
| XAHD60GBCN1 (the pairing on screen) | — | 24,0007.03 | 45,00013.19 | 46,00013.48 | 53% | 2.24 | NC | 20 |
Air handler · 1 indoor unit
-
JHETC60HBCS2N1 (the pairing on screen) brand not stated 29,800 Btu/h8.73 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| JHETC60HBCS2N1 (the pairing on screen) | — | 29,8008.73 | 45,00013.19 | 46,00013.48 | 66% | 2.84 | NC | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 7, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read