ZOV-36HDTB
ZOV-36HDTB is in the certified data.
Its certified full-speed heating output at 5°F is 26,000 Btu/h7.62 kW, 76% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
Zero · central heat pump
ZOV-36HDTB is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
34,0009.96NR
No 47°F rating for this pairing.
25,0007.33NR at 17°F
26,0007.62NR at 5°F
Btu/hkW, certified
1.90NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 34,000 Btu/h9.96 kW of heat at 47°F, 25,000 Btu/h7.33 kW at 17°F, and 26,000 Btu/h7.62 kW at 5°F, 76% of its 47°F rating. It delivers 34,000 Btu/h9.96 kW of cooling at 95°F. At 5°F that is 500 Btu/h0.15 kW short of the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 21,000 Btu/h6.15 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216445267 · listed by ZERO · certified Jan 30, 2025 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 26,0007.62 kW | −2% | 1.90 | |
| 17°Ffull speed | 25,0007.33 kW | −5% | NR | |
| 47°Fnormal speed | 34,0009.96 kW | −3% | NR | |
| 95°Fcooling, full load | 34,0009.96 kW | — | NR |
EER2 10.0 in that test. SEER2 19.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.01kW
- Electrical input in the 95°F cooling test
- 3.40kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 26,000 Btu/h7.62 kWNR
- This unit at 5°F median across its pairings
- 26,000 Btu/h7.62 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 44% of them, at number 252 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- TZID36H520ZCSThermal Zone · 26,000 Btu/h
- UCHA-36HDCSN4UTL and VKIN · 26,000 Btu/h
- YH3036GHFD18R2Pioneer · 26,000 Btu/h
- 27VPA936A*030*Carrier · 25,600 Btu/h
- MCHA-36HDCTO2MDX · 25,600 Btu/h
- HH836E2S11Champion, Coleman + 5 more · 25,400 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for ZOV-36HDTB
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 34,000 Btu/h9.96 kWNR | 34,000 Btu/h9.96 kW |
| Heat output at 17°F full speed | 25,000 Btu/h7.33 kWNR | 25,000 Btu/h7.33 kW |
| Heat output at 5°F full speed | 26,000 Btu/h7.62 kWNR | 26,000 Btu/h7.62 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 76%NR | |
| COP at 5°F full speed | 1.90NR | 1.90 |
| HSPF2 Region IV | 9.0NR | 9.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 34,000 Btu/h9.96 kWNR | 34,000 Btu/h9.96 kW |
| EER2 at 95°F | 10.0NR | 10.0 |
| SEER2 cooling season | 19.0NR | 19.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | ZAV-36HDTB | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | ZOV-36HDTB | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Air handler · 1 indoor unit
-
ZAV-36HDTB (the pairing on screen) brand not stated 26,000 Btu/h7.62 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| ZAV-36HDTB (the pairing on screen) | — | 26,0007.62 | 34,0009.96 | 34,0009.96 | 76% | 1.90 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- ZOV-36HDTB first appeared in the certified data between February 2025 and March 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 30, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read