Heat Pump List

Tools

Home Renovation Rebate: Northern Fuel Switch · page 13

CleanBC Better Homes · British Columbia, Canada · Open

CleanBC Better Homes pays CA$6,000 when a heat pump replaces gas, propane, or oil heat in a home north of 100 Mile House.

2,410 of the 2,914 certified heat pumps in our data sold in Canada meet the published thresholds for CA$6,000 of Home Renovation Rebate: Northern Fuel Switch as of Sep 28, 2026.

The program's own qualified product list decides which models it accepts. This page compares the certified figures with the thresholds the program publishes.

Programs change their thresholds. Check the program page before you buy.

The list

  1. 2401 SUZ-KA30NAHZMitsubishi Electric
    34,000 Btu/hheating at 47°F 27,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 32,000 Btu/h · Cold output 94% · HSPF2 8.5 · 3 pairings

  2. 2402 RD16AY60AJVCFriedrich, Rheem + 3 more
    51,000 Btu/hheating at 47°F 51,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 31,000 Btu/h · Cold output 53–61% · HSPF2 8.5 · 23 pairings

  3. 2403 AZPN/C36WDUIDKepler
    36,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 30,000 Btu/h · Cold output 83% · HSPF2 8.5 · 1 pairing

  4. 2404 DLCURAH36ACKMidea
    36,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 30,000 Btu/h · Cold output 83–97% · HSPF2 8.5 · 3 pairings

  5. 2405 MO1BE-H32B-2AMidea
    36,000 Btu/hheating at 47°F 32,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 26,400 Btu/h · Cold output 73–75% · HSPF2 8.5 · 5 pairings

  6. 36,000 Btu/hheating at 47°F 32,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 26,400 Btu/h · Cold output 73% · HSPF2 8.5 · 2 pairings

  7. 2407 E4HL5024A1000AAmerican Standard, Ameristar + 2 more
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 21,000 Btu/h · Cold output 71–88% · HSPF2 8.5 · 10 pairings

  8. 24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 21,000 Btu/h · Cold output 71–88% · HSPF2 8.5 · 12 pairings

  9. 2409 E4HL5018A1000AAmeristar, RunTru
    20,000 Btu/hheating at 47°F 20,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Central · 5°F 18,000 Btu/h · Cold output 90% · HSPF2 8.5 · 4 pairings

  10. 20,000 Btu/hheating at 47°F 20,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Central · 5°F 18,000 Btu/h · Cold output 89–90% · HSPF2 8.5 · 7 pairings

Home Renovation Rebate: Northern Fuel Switch, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2)
# Model Brands Type Size At 5°FBtu/h · heating At 47°FBtu/h · heating At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed SEER2median pairing HSPF2Btu/Wh · median pairing Compressor Refrigerant Market Pairings
2401 SUZ-KA30NAHZ Mitsubishi Electric Mini-split 24,000 Btu (2-ton)32,000 34,000 27,000 94% 1.75 15.2 8.5 Variable R-410A US CA 3
2402 RD16AY60AJVC Friedrich, Rheem + 3 more Central 48,000 Btu (4-ton)31,000 51,000 51,000 53–61% 2.20 15.2 8.5 Variable R-454B US CA 23
2403 AZPN/C36WDUID Kepler Central 36,000 Btu (3-ton)30,000 36,000 35,000 83% 1.80 15.2 8.5 Variable R-410A US CA 1
2404 DLCURAH36ACK Midea Central 36,000 Btu (3-ton)30,000 36,000 35,000 83–97% 1.80 15.2 8.5 Variable R-410A US CA 3
2405 MO1BE-H32B-2A Midea Central 30,000 Btu (2.5-ton)26,400 36,000 32,000 73–75% 2.00 15.2 8.5 Variable R-454B US CA 5
2406 MOD30-32HFN10-M3 MDV Central 30,000 Btu (2.5-ton)26,400 36,000 32,000 73% 2.00 15.2 8.5 Variable R-454B US CA 2
2407 E4HL5024A1000A American Standard, Ameristar + 2 more Central 24,000 Btu (2-ton)21,000 24,000 24,000 71–88% 1.85 15.2 8.5 Variable R-410A US CA 10
2408 THH24HAI2NAF2U23 TCL Central 24,000 Btu (2-ton)21,000 24,000 24,000 71–88% 1.85 15.2 8.5 Variable R-410A US CA 12
2409 E4HL5018A1000A Ameristar, RunTru Central 18,000 Btu (1.5-ton)18,000 20,000 20,000 90% 1.85 15.2 8.5 Variable R-410A US CA 4
2410 THH18HAI2NAF2U23 TCL Central 18,000 Btu (1.5-ton)18,000 20,000 20,000 89–90% 1.85 15.2 8.5 Variable R-410A US CA 7

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

10 of 2,410 units · page 13 of 13

Program specifications

Program specifications
Heat pump replacing fossil fuel heatCA$6,000 per home
RegionBritish Columbia, Canada
StatusOpen
Program pageThe program's own page
Qualified product listThe program's qualified product list
CheckedSep 28, 2026

Efficiency thresholds

Efficiency thresholds
RequirementPublished threshold
SEER2median certified pairing15.2 or more
HSPF2median certified pairing8.5 or more
Compressorcompressor type of the certified pairingsVariable speed

Other programs in British Columbia

Every heat pump rebate program

Excluded from this program

The program also requires removal of the fossil fuel heating system and a member of the Home Performance Contractor Network. The unit list does not check these.