Heat pumps for Arizona
Across the 417 ZIP-code areas in Arizona, the winter design temperature runs from 14°F to 43°F for most areas, with a median of 36°F.
The design temperature is the annual 99% value: only the coldest 88 hours of an average year fall below it. Each area takes it from the nearest weather station, 2015 to 2024.
Winter design temperatures across Arizona
| Design temperature | Areas | Share |
|---|---|---|
| Below 5°FNo certified heating figure | 0 | 0% |
| 5 to 17°F | 74 | 17.7% |
| 17 to 47°F | 343 | 82.3% |
| 47°F and above | 0 | 0% |
| Place | ZIP code | Design temperature |
|---|---|---|
| Cameron | 86020 | 6°F |
| Coconino County | 86016 | 6°F |
| Grand Canyon Village | 86023 | 6°F |
| Place | ZIP code | Design temperature |
|---|---|---|
| Fortuna Foothills | 85367 | 44°F |
| San Luis | 85336 | 44°F |
| Yuma | 85364 | 44°F |
Sizes certified to cover a typical house at 36°F
The size calculator uses 16 to 26 Btu/h per square foot for a typical house where the design temperature is 20°F or warmer. Sizes are compared on the 5°F full-speed test.
For each type: the smallest size class whose median model is certified to deliver the bottom of the range at 5°F, and the smallest that reaches the top. The medians count one value per model. Size classes are named by cooling capacity.
1,500 sq ft: 24,0007.03 to 39,000 Btu/h11.43 kW
- 36,000 Btu central models26,400 Btu/h7.74 kW at 5°F, the median of 451 models · covers the bottom of the range
- 54,000 Btu central models40,000 Btu/h11.72 kW at 5°F, the median of 343 models · covers the top of the range
- 30,000 Btu mini-split models25,000 Btu/h7.33 kW at 5°F, the median of 405 models · covers the bottom of the range
- 48,000 Btu mini-split models42,000 Btu/h12.31 kW at 5°F, the median of 321 models · covers the top of the range
2,500 sq ft: 40,00011.72 to 65,000 Btu/h19.05 kW
- 54,000 Btu central models40,000 Btu/h11.72 kW at 5°F, the median of 343 models · covers the bottom of the range
- No central size class reaches 65,000 Btu/h19.05 kW at 5°FThe top of this range takes more than one unit
- 48,000 Btu mini-split models42,000 Btu/h12.31 kW at 5°F, the median of 321 models · covers the bottom of the range
- No mini-split size class reaches 65,000 Btu/h19.05 kW at 5°FThe top of this range takes more than one unit
Your own house
6,618 of 8,420 certified units carry EPA's cold-climate designation. Cold-climate heat pumps by size
Every state and province
States
- Alabama
- Alaska
- Arizona
- Arkansas
- California
- Colorado
- Connecticut
- Delaware
- Florida
- Georgia
- Hawaii
- Idaho
- Illinois
- Indiana
- Iowa
- Kansas
- Kentucky
- Louisiana
- Maine
- Maryland
- Massachusetts
- Michigan
- Minnesota
- Mississippi
- Missouri
- Montana
- Nebraska
- Nevada
- New Hampshire
- New Jersey
- New Mexico
- New York
- North Carolina
- North Dakota
- Ohio
- Oklahoma
- Oregon
- Pennsylvania
- Rhode Island
- South Carolina
- South Dakota
- Tennessee
- Texas
- Utah
- Vermont
- Virginia
- Washington
- West Virginia
- Wisconsin
- Wyoming