Heat Pump List

Tools

Cold-climate heat pumps for Utah

Across the 299 ZIP-code areas in Utah, the winter design temperature runs from 2°F to 20°F for most areas, with a median of 13°F.

The design temperature is the annual 99% value: only the coldest 88 hours of an average year fall below it. Each area takes it from the nearest weather station, 2015 to 2024.

Winter design temperatures across Utah

ZIP-code areas in Utah, by design temperature
Design temperature Areas Share
Below 5°FNo certified heating figure 45 15.1%
5 to 17°F 147 49.2%
17 to 47°F 107 35.8%
47°F and above 0 0%
Coldest areas in Utah
Place ZIP code Design temperature
Alton 84710 −1°F
Antimony 84712 −1°F
Beaver 84713 −1°F
Warmest areas in Utah
Place ZIP code Design temperature
Dammeron Valley 84783 28°F
Hildale 84784 28°F
Hurricane 84737 28°F

Sizes certified to cover a typical house at 13°F

The size calculator uses 18 to 30 Btu/h per square foot for a typical house where the design temperature is 0 to 19°F. Sizes are compared on the 5°F full-speed test.

For each type: the smallest size class whose median model is certified to deliver the bottom of the range at 5°F, and the smallest that reaches the top. The medians count one value per model. Size classes are named by cooling capacity.

1,500 sq ft: 27,000 to 45,000 Btu/h

2,500 sq ft: 45,000 to 75,000 Btu/h

Your own house

6,618 of 8,420 certified units carry EPA's cold-climate designation. Cold-climate heat pumps by size

Estimate for your house

Every state and province

States

Provinces