Heat Pump List

Tools

4TWV0X36A1

4TWV0X36A1 is in the certified data.

Its certified full-speed heating output at 5°F is 19,000–22,400 Btu/h, 60–66% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Trane · central heat pump

All 104 certified Trane models

4TWV0X36A1 is in the certified data as of Sep 19, 2026.

210 certified pairings with 132 different figures. See all

Certified heating and cooling

Heating at 47°F

31,400

26,400 at 17°F

20,400 at 5°F

Btu/h, certified

1.79 COP at 5°F

Cooling at 95°F

34,000

Btu/h, certified

EER2 12.0 at 95°F

SEER2 19.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for 4TWV0X36A1, by outdoor temperature Heating: 20,400 Btu/h at 5°F, 26,400 Btu/h at 17°F, 31,400 Btu/h at 47°F. Cooling: 34,000 Btu/h at 95°F. The bars start at zero. Median of 3-ton central models: 26,400 Btu/h at 5°F, 26,200 Btu/h at 17°F, 35,200 Btu/h at 47°F, 35,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 20,400 5°F 26,400 17°F 31,400 47°F 34,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 31,400 Btu/h of heat at 47°F, 26,400 Btu/h at 17°F, and 20,400 Btu/h at 5°F, 65% of its 47°F rating. It delivers 34,000 Btu/h of cooling at 95°F. At 5°F that is 6,100 Btu/h short of the example heating load of 26,500 Btu/h; at 95°F it is 21,000 Btu/h above the example cooling load of 13,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 210691823 · listed by Trane · certified Jul 9, 2025 · 4 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 51 programs in 29 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Colorado (1), Delaware (2), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (1), New Jersey (6), New York (4), North Carolina (1), Oregon (2), Pennsylvania (4), South Carolina (1), Tennessee (1), Texas (3), Utah (1), Vermont (3), Washington (2), Wisconsin (1), British Columbia (3), Newfoundland and Labrador (1).

All 51 programs by state and province

Alabama

Arizona

California

Colorado

Delaware

Idaho

Illinois

Kansas

Kentucky

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 20,4005.98 kW −23% 1.79
17°Ffull speed 26,4007.74 kW +1% NR
47°Fnormal speed 31,4009.20 kW −11% NR
95°Fcooling, full load 34,0009.96 kW — NR

EER2 12.0 in that test. SEER2 19.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.34kW
Electrical input in the 95°F cooling test
2.83kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton central models

This pairing at 5°F
20,400 Btu/h
This unit at 5°F median across its pairings
20,400 Btu/h
Median of 3-ton central models at 5°F
26,400 Btu/h
Models in this group
451

This unit is above 30% of them, at number 316 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 36,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 298th of 451; HSPF2, 222nd of 467 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • HH836E2S11: The same 31,600 Btu/h rating at 47°F; 25,400 Btu/h at 5°F (this model: 20,400).
  • A7CP21V36P-**A: The same 31,600 Btu/h rating at 47°F; HSPF2 9.0 (this model: 8.5).
  • SL22KLV-036-230A: 31,400 Btu/h at 47°F (this model: 31,600); 27,200 Btu/h at 5°F (this model: 20,400).

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 20,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42490–850
MildTypical16–26780–1,280
MildTight, well insulated10–181,130–2,040
ColdDrafty, little insulation28–52390–730
ColdTypical18–30680–1,130
ColdTight, well insulated12–22930–1,700
Very coldDrafty, little insulation32–58350–640
Very coldTypical22–38540–930
Very coldTight, well insulated16–28730–1,280

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for 4TWV0X36A1

210 pairings · 210 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for 4TWV0X36A1
This pairingAll pairings
Heating
Heat output at 47°F normal speed 31,400 Btu/h 29,800–35,400 Btu/h
Heat output at 17°F full speed 26,400 Btu/h 24,400–29,000 Btu/h
Heat output at 5°F full speed 20,400 Btu/h 19,000–22,400 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 65%
COP at 5°F full speed 1.79 1.60–1.92
HSPF2 Region IV 8.5 8.0–8.7
Cooling
Cooling capacity at 95°F full-load test 34,000 Btu/h 32,200–36,000 Btu/h
EER2 at 95°F 12.0 11.2–12.7
SEER2 cooling season 19.5 17.5–20.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit 4PX*CU36BS3 31 indoor units
FurnaceS8V2C080M5PCA 65 furnaces
Cold-climate designation EPA's designation, as published NC On some pairings
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified 4TWV0X36A1

Across 210 certified pairings with 31 indoor models: heat at 5°F 19,000 Btu/h with 4PX*BU36BS3+P0V0A000M30SC+RP to 22,400 Btu/h with 4TXCB004DS3; HSPF2 8.0 with 4PX*BD36BS3 to 8.7 with 4PX*BU36BS3; SEER2 17.5 with 4PX*BU36BS3+P0V0B000M40SC+RP to 20.5 with 4PX*BD42BS3. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

31 indoor units · 210 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. 4PX*BU36BS3 brand not stated 20,400 Btu/hat 5°F, full speed

    35 pairings, 35 with a furnace · 47°F 31,600 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 65% · COP 1.77

  2. 4TXCB004DS3 brand not stated 20,400 Btu/hat 5°F, full speed

    33 pairings, 33 with a furnace · 47°F 31,600 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 65% · COP 1.77

  3. 4PX*BD42BS3 brand not stated 20,600 Btu/hat 5°F, full speed

    19 pairings, 19 with a furnace · 47°F 31,400 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 66% · COP 1.73

  4. 4PX*CU42BS3 brand not stated 20,400 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 32,600 Btu/h · 95°F cooling 35,300 Btu/h · Cold output 63% · COP 1.80

  5. 4PX*CU48BS3 brand not stated 20,400 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 32,000 Btu/h · 95°F cooling 35,300 Btu/h · Cold output 64% · COP 1.82

  6. 4TXCC005DS3 brand not stated 20,400 Btu/hat 5°F, full speed

    14 pairings, 14 with a furnace · 47°F 31,400 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 65% · COP 1.78

  7. 4PX*BD36BS3 brand not stated 21,000 Btu/hat 5°F, full speed

    13 pairings, 13 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 34,600 Btu/h · Cold output 64% · COP 1.64

  8. 4PX*CU36BS3 (the pairing on screen) brand not stated 20,400 Btu/hat 5°F, full speed

    13 pairings, 13 with a furnace · 47°F 31,400 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 65% · COP 1.80

  9. 4PX*CD42BS3 brand not stated 20,300 Btu/hat 5°F, full speed

    12 pairings, 12 with a furnace · 47°F 31,200 Btu/h · 95°F cooling 35,800 Btu/h · Cold output 65% · COP 1.73

  10. 4PX*CD36BS3 brand not stated 20,800 Btu/hat 5°F, full speed

    11 pairings, 11 with a furnace · 47°F 32,800 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 63% · COP 1.63

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
4PX*BU36BS3 — 20,400 31,600 34,400 65% 1.77 NC 35
4TXCB004DS3 — 20,400 31,600 34,400 65% 1.77 NC 33
4PX*BD42BS3 — 20,600 31,400 36,000 66% 1.73 NC 19
4PX*CU42BS3 — 20,400 32,600 35,300 63% 1.80 NC 16
4PX*CU48BS3 — 20,400 32,000 35,300 64% 1.82 NC 16
4TXCC005DS3 — 20,400 31,400 34,400 65% 1.78 NC 14
4PX*BD36BS3 — 21,000 33,000 34,600 64% 1.64 NC 13
4PX*CU36BS3 (the pairing on screen) — 20,400 31,400 34,400 65% 1.80 NC 13
4PX*CD42BS3 — 20,300 31,200 35,800 65% 1.73 NC 12
4PX*CD36BS3 — 20,800 32,800 34,400 63% 1.63 NC 11

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 31 indoor units All 210 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

History and definitions

Other XV20I models by nominal cooling size: 4TWV0X24A1 (24,000 Btu), 4TWV0048A1 (48,000 Btu), 4TWV0X48A1 (48,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Jul 9, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “4TWV0X36A1 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/4twv0x36a1