50VR-K60---30
50VR-K60---30 is in the certified data.
Its certified full-speed heating output at 5°F is 22,200 Btu/h6.51 kW, 39% of its 47°F rating in its certified pairing.
Carrier · central heat pump
All 187 certified Carrier models
50VR-K60---30 is in the certified data as of Sep 19, 2026.
- 54,000 Btu (4.5-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
56,50016.56NR
No 47°F rating for this pairing.
32,4009.50NR at 17°F
22,2006.51NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 56,500 Btu/h16.56 kW of heat at 47°F, 32,400 Btu/h9.50 kW at 17°F, and 22,200 Btu/h6.51 kW at 5°F, 39% of its 47°F rating. It delivers 56,000 Btu/h16.41 kW of cooling at 95°F. At 5°F that is 17,800 Btu/h5.22 kW short of the example heating load of 40,000 Btu/h11.72 kW; at 95°F it is 36,000 Btu/h10.55 kW above the example cooling load of 20,000 Btu/h5.86 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h11.72 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h5.86 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 212406353 · listed by Carrier · certified Feb 17, 2025 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 12 programs in 10 states, provinces, or territories:Idaho (1), Kansas (1), Maryland (3), Michigan (2), North Carolina (1), Oregon (2), South Carolina (1), Texas (1), Utah (1), Newfoundland and Labrador (1).
All 12 programs by state and province
Idaho
Kansas
Maryland
- BGE Smart Energy Savers Heating and Cooling
- Delmarva Power Maryland HVAC Efficiency Program
- Pepco Maryland HVAC Efficiency Program
Michigan
North Carolina
Oregon
- Energy Trust of Oregon Heat Pump Incentives · Portland General Electric (PGE) · Pacific Power
- Idaho Power Heating and Cooling Efficiency Program
South Carolina
Texas
Utah
Newfoundland and Labrador
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 22,2006.51 kW | −45% | 2.00 | |
| 17°Fone compressor speed | 32,4009.50 kW | −14% | NR | |
| 47°Fone compressor speed | 56,50016.56 kW | +1% | NR | |
| 95°Fcooling, full load | 56,00016.41 kW | — | NR |
EER2 11.5 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.25kW
- Electrical input in the 95°F cooling test
- 4.87kW
- Seasonal average heating COP
- 2.20
These exclude backup resistance heat.
How it compares with other 54,000 Btu heat pumps
4.5-ton central models
- This pairing at 5°F
- 22,200 Btu/h6.51 kWNR
- This unit at 5°F median across its pairings
- 22,200 Btu/h6.51 kW
- Median of 4.5-ton central models at 5°F
- 40,000 Btu/h11.72 kW
- Models in this group
- 343
This unit is above 1% of them, at number 340 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.
Among 54,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 336th of 343 (tied); HSPF2, 343rd of 358 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- RP17AY60AJVC: The same 56,500 Btu/h rating at 47°F; 45,500 Btu/h at 5°F (this model: 22,200).
- FOP1560TJAZNA: The same 56,500 Btu/h rating at 47°F; 33,600 Btu/h at 5°F (this model: 22,200).
- YH560E2S11: The same 56,500 Btu/h rating at 47°F; 31,600 Btu/h at 5°F (this model: 22,200).
Closest models by heat at 5°F
- WP14AY60AJ2NFujitsu, Rheem + 2 more · 25,800 Btu/h
- DRHP14B60AJ2ANDuraSTAR · 25,000 Btu/h
- DRHP15B60AJ2ANDuraSTAR · 25,000 Btu/h
- RHPXYC060AJTFriedrich, Mainline + 5 more · 25,000 Btu/h
- LRP15HPK60VPLennox · 24,600 Btu/h
- GSZH506010AGoodman · 21,600 Btu/h
Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 22,200 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 530–930 |
| Mild | Typical | 16–26 | 850–1,390 |
| Mild | Tight, well insulated | 10–18 | 1,230–2,220 |
| Cold | Drafty, little insulation | 28–52 | 430–790 |
| Cold | Typical | 18–30 | 740–1,230 |
| Cold | Tight, well insulated | 12–22 | 1,010–1,850 |
| Very cold | Drafty, little insulation | 32–58 | 380–690 |
| Very cold | Typical | 22–38 | 580–1,010 |
| Very cold | Tight, well insulated | 16–28 | 790–1,390 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for 50VR-K60---30
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 56,500 Btu/h16.56 kWNR | 56,500 Btu/h16.56 kW |
| Heat output at 17°F full speed | 32,400 Btu/h9.50 kWNR | 32,400 Btu/h9.50 kW |
| Heat output at 5°F full speed | 22,200 Btu/h6.51 kWNR | 22,200 Btu/h6.51 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 39%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 7.5NR | 7.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 56,000 Btu/h16.41 kWNR | 56,000 Btu/h16.41 kW |
| EER2 at 95°F | 11.5NR | 11.5 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 50VR-K60---30* | |
Pairings, by indoor-unit class
1 certified pairing
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 22,200 Btu/h6.51 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 22,2006.51 | 56,50016.56 | 56,00016.41 | 39% | 2.00 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
5 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 48VR*K60***30*Carrier
- 607ENXK60000AABryant
- 677ENWK60****A*Bryant
- PHR560000K***K1ACiQ · Airquest · Arcoaire · Comfortmaker · Day & Night · Heil · ICP Commercial · Keeprite · Kenmore · Maratherm · Tempstar
4 of 5 shown.
Other model numbers with identical certified values
4 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 48VR*K60***30*identical certified values
- 607ENXK60000AAidentical certified values
- 677ENWK60****A*identical certified values
3 of 4 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other Performance HP models by nominal cooling size: 50NR-B24---30 (24,000 Btu), 50VR-K24---30 (24,000 Btu), 50NR-B36---30 (36,000 Btu), 50VR-K36---30 (36,000 Btu), 50NR-B48---30 (48,000 Btu), 50VR-K48---30 (48,000 Btu), 50NR-B60---30 (54,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Feb 17, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read