Heat Pump List

Tools

5WCZ5030A1

American Standard and Trane · central heat pump

All 88 certified American Standard models · All 104 certified Trane models

5WCZ5030A1 is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

28,800

17,300 at 17°F

14,700 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

29,600

Btu/h, certified

EER2 11.2 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for 5WCZ5030A1, by outdoor temperature Heating: 14,700 Btu/h at 5°F, 17,300 Btu/h at 17°F, 28,800 Btu/h at 47°F. Cooling: 29,600 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton central models: 22,400 Btu/h at 5°F, 20,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 Btu/h 14,700 5°F 17,300 17°F 28,800 47°F 29,600 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 28,800 Btu/h of heat at 47°F, 17,300 Btu/h at 17°F, and 14,700 Btu/h at 5°F, 51% of its 47°F rating. It delivers 29,600 Btu/h of cooling at 95°F. At 5°F that is 7,800 Btu/h short of the example heating load of 22,500 Btu/h; at 95°F it is 18,100 Btu/h above the example cooling load of 11,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 216574934 · listed by Trane · certified Dec 16, 2025 · 2 pairings on 2 certificates share these values

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 14,7004.31 kW −34% 2.00
17°Ffull speed 17,3005.07 kW −16% NR
47°Fhigh stage 28,8008.44 kW −4% NR
95°Fcooling, full load 29,6008.67 kW — NR

EER2 11.2 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.15kW
Electrical input in the 95°F cooling test
2.64kW
Seasonal average heating COP
2.11

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton central models

This pairing at 5°F
14,700 Btu/h
This unit at 5°F median across its pairings
14,700 Btu/h
Median of 2.5-ton central models at 5°F
22,400 Btu/h
Models in this group
288

This unit is above 29% of them, at number 204 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 30,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 221st of 288 (tied); HSPF2, 289th of 290 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • W5H5S30*K*AAA*: The same 28,800 Btu/h rating at 47°F; HSPF2 7.95 (this model: 7.2).
  • CU-HM30BAHU: 29,000 Btu/h at 47°F (this model: 28,800); 29,000 Btu/h at 5°F (this model: 14,700).
  • MVP-30-HP-C-230A00-O: 29,000 Btu/h at 47°F (this model: 28,800); 19,000 Btu/h at 5°F (this model: 14,700).

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 14,700 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42350–610
MildTypical16–26570–920
MildTight, well insulated10–18820–1,470
ColdDrafty, little insulation28–52280–530
ColdTypical18–30490–820
ColdTight, well insulated12–22670–1,230
Very coldDrafty, little insulation32–58250–460
Very coldTypical22–38390–670
Very coldTight, well insulated16–28530–920

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for 5WCZ5030A1

2 pairings · 2 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for 5WCZ5030A1
This pairingAll pairings
Heating
Heat output at 47°F high stage 28,800 Btu/h 28,800 Btu/h
Heat output at 17°F full speed 17,300 Btu/h 17,300 Btu/h
Heat output at 5°F full speed 14,700 Btu/h 14,700 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 51%
COP at 5°F full speed 2.00 2.00
HSPF2 Region IV 7.2 7.2
Cooling
Cooling capacity at 95°F full-load test 29,600 Btu/h 29,600 Btu/h
EER2 at 95°F 11.2 11.2
SEER2 cooling season 15.2 15.2
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Two-stage
Indoor unit None listed None
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold United States United States
Model string as certified 5WCZ5030A1

Pairings, by indoor-unit class

2 certified pairings

One row per indoor unit certified with this outdoor unit.

Unspecified

  1. None listed (the pairing on screen) brand not stated 14,700 Btu/hat 5°F, full speed

    2 pairings · 47°F 28,800 Btu/h · 95°F cooling 29,600 Btu/h · Cold output 51% · COP 2.00

Indoor units in the unspecified class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
None listed (the pairing on screen) — 14,700 28,800 29,600 51% 2.00 NC 2

The share is heat output at 5°F divided by the 47°F rating.

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Other model numbers with identical certified values

2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

History and definitions

Other 5WCZ5 models by nominal cooling size: 5WCZ5036A1 (36,000 Btu), 5WCZ5048A1 (48,000 Btu), 5WCZ5060A1 (60,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Dec 16, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read