5WCZ5048A1
5WCZ5048A1 is in the certified data.
Its certified full-speed heating output at 5°F is 22,000 Btu/h6.45 kW, 52% of its 47°F rating across its certified pairings.
American Standard and Trane · central heat pump
All 88 certified American Standard models · All 104 certified Trane models
5WCZ5048A1 is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Central
- Two-stage
- United States
Certified heating and cooling
Heating at 47°F
42,00012.31NR
No 47°F rating for this pairing.
28,0008.21NR at 17°F
22,0006.45NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 42,000 Btu/h12.31 kW of heat at 47°F, 28,000 Btu/h8.21 kW at 17°F, and 22,000 Btu/h6.45 kW at 5°F, 52% of its 47°F rating. It delivers 46,000 Btu/h13.48 kW of cooling at 95°F. At 5°F that is 14,500 Btu/h4.25 kW short of the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 28,000 Btu/h8.21 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216574940 · listed by Trane · certified Sep 30, 2026 · 2 pairings on 2 certificates share these values
Rebates where you live
Meets the recorded equipment thresholds of 23 programs in 18 states, provinces, or territories:California (1), Idaho (2), Illinois (1), Kansas (1), Maryland (3), Michigan (2), Minnesota (2), Mississippi (1), Nevada (1), New Hampshire (1), North Carolina (1), Oregon (2), Pennsylvania (1), South Carolina (1), Texas (2), Utah (1), Washington (2), Wisconsin (1).
All 23 programs by state and province
California
Idaho
Illinois
Kansas
Maryland
- BGE Smart Energy Savers Heating and Cooling
- Delmarva Power Maryland HVAC Efficiency Program
- Pepco Maryland HVAC Efficiency Program
Michigan
Minnesota
- Wright-Hennepin Air Source Heat Pump Rebate · Wright-Hennepin Cooperative Electric Association
- Xcel Energy Minnesota Air Source Heat Pump Rebates
Mississippi
Nevada
New Hampshire
North Carolina
Oregon
- Energy Trust of Oregon Heat Pump Incentives · Portland General Electric (PGE) · Pacific Power
- Idaho Power Heating and Cooling Efficiency Program
Pennsylvania
South Carolina
Texas
- Austin Energy Air Conditioning and Heat Pump Rebate
- CenterPoint Residential Standard Offer Program · CenterPoint Energy
Utah
Washington
Wisconsin
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 22,0006.45 kW | −40% | 2.00 | |
| 17°Fone compressor speed | 28,0008.21 kW | −20% | NR | |
| 47°Fone compressor speed | 42,00012.31 kW | −13% | NR | |
| 95°Fcooling, full load | 46,00013.48 kW | — | NR |
EER2 11.5 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.22kW
- Electrical input in the 95°F cooling test
- 4.00kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 22,000 Btu/h6.45 kWNR
- This unit at 5°F median across its pairings
- 22,000 Btu/h6.45 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 6% of them, at number 384 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Among 48,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 333rd of 408; HSPF2, 297th of 420 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- 4TWV0X48A1: The same 42,000 Btu/h rating at 47°F; 27,800 Btu/h at 5°F (this model: 22,000).
- 4TWL9048A1: The same 42,000 Btu/h rating at 47°F; HSPF2 9.0 (this model: 8.1).
- 4TWV8X48A1: 43,000 Btu/h at 47°F (this model: 42,000); 28,400 Btu/h at 5°F (this model: 22,000).
Closest models by heat at 5°F
- WP15AY48AJ2NFujitsu, Rheem + 2 more · 23,000 Btu/h
- ML16KP2-048-230ALennox · 22,600 Btu/h
- 5DCZ5048A1American Standard and Trane · 22,000 Btu/h
- GSZC704810AGoodman · 22,000 Btu/h
- RP14AY48AJ2NRheem and Ruud · 21,200 Btu/h
- DHH0481********A*Daikin · 21,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 22,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 520–920 |
| Mild | Typical | 16–26 | 850–1,380 |
| Mild | Tight, well insulated | 10–18 | 1,220–2,200 |
| Cold | Drafty, little insulation | 28–52 | 420–790 |
| Cold | Typical | 18–30 | 730–1,220 |
| Cold | Tight, well insulated | 12–22 | 1,000–1,830 |
| Very cold | Drafty, little insulation | 32–58 | 380–690 |
| Very cold | Typical | 22–38 | 580–1,000 |
| Very cold | Tight, well insulated | 16–28 | 790–1,380 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for 5WCZ5048A1
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 42,000 Btu/h12.31 kWNR | 42,000 Btu/h12.31 kW |
| Heat output at 17°F full speed | 28,000 Btu/h8.21 kWNR | 28,000 Btu/h8.21 kW |
| Heat output at 5°F full speed | 22,000 Btu/h6.45 kWNR | 22,000 Btu/h6.45 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 52%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 8.1NR | 8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 46,000 Btu/h13.48 kWNR | 46,000 Btu/h13.48 kW |
| EER2 at 95°F | 11.5NR | 11.5 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | United States | United States |
| Model string as certified | 5WCZ5048A1 | |
Pairings, by indoor-unit class
2 certified pairings
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 22,000 Btu/h6.45 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 22,0006.45 | 42,00012.31 | 46,00013.48 | 52% | 2.00 | NC | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- 5WCZ5048A1 2 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- 5WCZ5048A1 first appeared in the certified data between March 2025 and May 2025.
History and definitions
Other 5WCZ5 models by nominal cooling size: 5WCZ5036A1 (36,000 Btu), 5WCZ5060A1 (60,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Sep 30, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read