5WCZ5060A1
5WCZ5060A1 is in the certified data.
Its certified full-speed heating output at 5°F is 29,600 Btu/h8.67 kW, 53% of its 47°F rating across its certified pairings.
American Standard and Trane · central heat pump
All 88 certified American Standard models · All 104 certified Trane models
5WCZ5060A1 is in the certified data as of Sep 19, 2026.
- 60,000 Btu (5-ton)
- Central
- Two-stage
- United States
Certified heating and cooling
Heating at 47°F
56,00016.41NR
No 47°F rating for this pairing.
37,00010.84NR at 17°F
29,6008.67NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 56,000 Btu/h16.41 kW of heat at 47°F, 37,000 Btu/h10.84 kW at 17°F, and 29,600 Btu/h8.67 kW at 5°F, 53% of its 47°F rating. It delivers 58,000 Btu/h17.00 kW of cooling at 95°F. At 5°F that is 16,900 Btu/h4.95 kW short of the example heating load of 46,500 Btu/h13.63 kW; at 95°F it is 34,500 Btu/h10.11 kW above the example cooling load of 23,500 Btu/h6.89 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of all 5-ton models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,950 sq ft where winters reach 5°F: heating runs from 46,500 Btu/h13.63 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 23,500 Btu/h6.89 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216574942 · listed by Trane · certified Dec 16, 2025 · 2 pairings on 2 certificates share these values
Rebates where you live
Meets the recorded equipment thresholds of 5 programs in 5 states, provinces, or territories:California (1), Idaho (1), Kansas (1), Michigan (2), Oregon (1).
All 5 programs by state and province
California
Idaho
Kansas
Michigan
Oregon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 29,6008.67 kW | −36% | 2.00 | |
| 17°Fone compressor speed | 37,00010.84 kW | −10% | NR | |
| 47°Fone compressor speed | 56,00016.41 kW | −13% | NR | |
| 95°Fcooling, full load | 58,00017.00 kW | — | NR |
EER2 11.5 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.34kW
- Electrical input in the 95°F cooling test
- 5.04kW
- Seasonal average heating COP
- 2.11
These exclude backup resistance heat.
How it compares with other 60,000 Btu heat pumps
All 5-ton models
- This pairing at 5°F
- 29,600 Btu/h8.67 kWNR
- This unit at 5°F median across its pairings
- 29,600 Btu/h8.67 kW
- Median of all 5-ton models at 5°F
- 46,500 Btu/h13.63 kW
- Models in this group
- 34
This unit is above 6% of them, at number 32 of 34 by heat at 5°F. The middle half of the group runs 42,000 to 47,000 Btu/h.
Among 60,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 1st of 4; HSPF2, 3rd of 5 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- ML16KP2-060-230A: 53,500 Btu/h at 47°F (this model: 56,000); HSPF2 7.8 (this model: 7.2).
- DHH0601********A*: 59,000 Btu/h at 47°F (this model: 56,000); HSPF2 7.7 (this model: 7.2).
Closest models by heat at 5°F
- TVRF-V60WL/CTosot · 42,000 Btu/h
- MCY-MUB0608HS2P-ULToshiba Carrier · 38,500 Btu/h
- HVAHP060C23SHitachi · 35,400 Btu/h
- 5DCZ5060A1American Standard and Trane · 29,600 Btu/h
- ML16KP2-060-230ALennox · 27,800 Btu/h
- DHH0601********A*Daikin · 27,000 Btu/h
Every 60,000 Btu (5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 29,600 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 700–1,230 |
| Mild | Typical | 16–26 | 1,140–1,850 |
| Mild | Tight, well insulated | 10–18 | 1,640–2,960 |
| Cold | Drafty, little insulation | 28–52 | 570–1,060 |
| Cold | Typical | 18–30 | 990–1,640 |
| Cold | Tight, well insulated | 12–22 | 1,350–2,470 |
| Very cold | Drafty, little insulation | 32–58 | 510–930 |
| Very cold | Typical | 22–38 | 780–1,350 |
| Very cold | Tight, well insulated | 16–28 | 1,060–1,850 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for 5WCZ5060A1
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 56,000 Btu/h16.41 kWNR | 56,000 Btu/h16.41 kW |
| Heat output at 17°F full speed | 37,000 Btu/h10.84 kWNR | 37,000 Btu/h10.84 kW |
| Heat output at 5°F full speed | 29,600 Btu/h8.67 kWNR | 29,600 Btu/h8.67 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 53%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 7.2NR | 7.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 58,000 Btu/h17.00 kWNR | 58,000 Btu/h17.00 kW |
| EER2 at 95°F | 11.5NR | 11.5 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | United States | United States |
| Model string as certified | 5WCZ5060A1 | |
Pairings, by indoor-unit class
2 certified pairings
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 29,600 Btu/h8.67 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 29,6008.67 | 56,00016.41 | 58,00017.00 | 53% | 2.00 | NC | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- 5WCZ5060A1 2 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other 5WCZ5 models by nominal cooling size: 5WCZ5036A1 (36,000 Btu), 5WCZ5048A1 (48,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Dec 16, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read