DHH0601********A*
DHH0601********A* is in the certified data.
Its certified full-speed heating output at 5°F is 27,000 Btu/h7.91 kW, 46% of its 47°F rating in its certified pairing.
Daikin · central heat pump
DHH0601********A* is in the certified data as of Sep 19, 2026. DHH0601********A* changed its certified SEER2 on AHRI certificate 216018413 from 16.8 to 16.4 in the certified data between August 2025 and September 2026.
- 60,000 Btu (5-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
59,00017.29NR
No 47°F rating for this pairing.
35,00010.26NR at 17°F
27,0007.91NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 59,000 Btu/h17.29 kW of heat at 47°F, 35,000 Btu/h10.26 kW at 17°F, and 27,000 Btu/h7.91 kW at 5°F, 46% of its 47°F rating. It delivers 60,000 Btu/h17.58 kW of cooling at 95°F. At 5°F that is 19,500 Btu/h5.71 kW short of the example heating load of 46,500 Btu/h13.63 kW; at 95°F it is 36,500 Btu/h10.70 kW above the example cooling load of 23,500 Btu/h6.89 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of all 5-ton models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,950 sq ft where winters reach 5°F: heating runs from 46,500 Btu/h13.63 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 23,500 Btu/h6.89 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216018413 · listed by Daikin · certified Feb 11, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 27,0007.91 kW | −42% | 2.00 | |
| 17°Fone compressor speed | 35,00010.26 kW | −15% | NR | |
| 47°Fone compressor speed | 59,00017.29 kW | −9% | NR | |
| 95°Fcooling, full load | 60,00017.58 kW | — | NR |
EER2 12.2 in that test. SEER2 16.4 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.96kW
- Electrical input in the 95°F cooling test
- 4.92kW
- Seasonal average heating COP
- 2.26
These exclude backup resistance heat.
How it compares with other 60,000 Btu heat pumps
All 5-ton models
- This pairing at 5°F
- 27,000 Btu/h7.91 kWNR
- This unit at 5°F median across its pairings
- 27,000 Btu/h7.91 kW
- Median of all 5-ton models at 5°F
- 46,500 Btu/h13.63 kW
- Models in this group
- 34
This unit is above 0% of them, at number 34 of 34 by heat at 5°F. The middle half of the group runs 42,000 to 47,000 Btu/h.
Closest models by heat at 5°F
- TVRF-V60WL/CTosot · 42,000 Btu/h
- MCY-MUB0608HS2P-ULToshiba Carrier · 38,500 Btu/h
- HVAHP060C23SHitachi · 35,400 Btu/h
- 5DCZ5060A1American Standard and Trane · 29,600 Btu/h
- 5WCZ5060A1American Standard and Trane · 29,600 Btu/h
- ML16KP2-060-230ALennox · 27,800 Btu/h
Every 60,000 Btu (5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for DHH0601********A*
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 59,000 Btu/h17.29 kWNR | 59,000 Btu/h17.29 kW |
| Heat output at 17°F full speed | 35,000 Btu/h10.26 kWNR | 35,000 Btu/h10.26 kW |
| Heat output at 5°F full speed | 27,000 Btu/h7.91 kWNR | 27,000 Btu/h7.91 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 46%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 7.7NR | 7.7 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 60,000 Btu/h17.58 kWNR | 60,000 Btu/h17.58 kW |
| EER2 at 95°F | 12.2NR | 12.2 |
| SEER2 cooling season | 16.4NR | 16.4 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Two-stage | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | DHH0601********A* | |
Pairings, by indoor-unit class
1 certified pairing
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 27,000 Btu/h7.91 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 27,0007.91 | 59,00017.29 | 60,00017.58 | 46% | 2.00 | NC | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- DHH0601********A* changed its certified SEER2 on AHRI certificate 216018413 from 16.8 to 16.4 in the certified data between August 2025 and September 2026.
- DHH0601********A* changed its certified heat output at 5°F on AHRI certificate 216018413 from 24,000 Btu/h to 27,000 Btu/h in the certified data between August 2025 and September 2026.
- DHH0601********A* first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Feb 11, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read