ML16KP2-060-230A is in the certified data.

Its certified full-speed heating output at 5°F is 27,800 Btu/h, 51–52% of its 47°F rating, depending on the pairing.

Lennox · central heat pump

ML16KP2-060-230A is in the certified data as of Sep 19, 2026.

2 certified pairings with 2 different figures. See all

Certified heating and cooling

Heating at 47°F

53,500

34,200 at 17°F

27,800 at 5°F

Btu/h, certified

2.10 COP at 5°F

Cooling at 95°F

57,500

Btu/h, certified

EER2 12.0 at 95°F

SEER2 15.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for ML16KP2-060-230A, by outdoor temperature Heating: 27,800 Btu/h at 5°F, 34,200 Btu/h at 17°F, 53,500 Btu/h at 47°F. Cooling: 57,500 Btu/h at 95°F. The bars start at zero. Median of all 5-ton models: 46,500 Btu/h at 5°F, 41,000 Btu/h at 17°F, 64,500 Btu/h at 47°F, 60,000 Btu/h at 95°F. 0 20,000 40,000 60,000 80,000 Btu/h 27,800 5°F 34,200 17°F 53,500 47°F 57,500 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of all 5-ton models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 53,500 Btu/h of heat at 47°F, 34,200 Btu/h at 17°F, and 27,800 Btu/h at 5°F, 52% of its 47°F rating. It delivers 57,500 Btu/h of cooling at 95°F. At 5°F that is 18,700 Btu/h short of the example heating load of 46,500 Btu/h; at 95°F it is 34,000 Btu/h above the example cooling load of 23,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of all 5-ton models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,950 sq ft where winters reach 5°F: heating runs from 46,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 23,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218630629 · listed by Lennox · certified Jul 17, 2026 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of all 5-ton models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 27,8008.15 kW −40% 2.10
17°Fone compressor speed 34,20010.02 kW −17% NR
47°Fone compressor speed 53,50015.68 kW −17% NR
95°Fcooling, full load 57,50016.85 kW — NR

EER2 12.0 in that test. SEER2 15.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.88kW
Electrical input in the 95°F cooling test
4.79kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 60,000 Btu heat pumps

All 5-ton models

This pairing at 5°F
27,800 Btu/h
This unit at 5°F median across its pairings
27,800 Btu/h
Median of all 5-ton models at 5°F
46,500 Btu/h
Models in this group
34

This unit is above 3% of them, at number 33 of 34 by heat at 5°F. The middle half of the group runs 42,000 to 47,000 Btu/h.

Fewer than 30 models of this size share this unit's type, so the comparison is every type in the class.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 60,000 Btu (5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for ML16KP2-060-230A

2 pairings · 2 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for ML16KP2-060-230A
This pairingAll pairings
Heating
Heat output at 47°F high stage 53,500 Btu/h 53,500–54,500 Btu/h
Heat output at 17°F full speed 34,200 Btu/h 34,200 Btu/h
Heat output at 5°F full speed 27,800 Btu/h 27,800 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 52%
COP at 5°F full speed 2.10 2.10
HSPF2 Region IV 7.8 7.8
Cooling
Cooling capacity at 95°F full-load test 57,500 Btu/h 57,500–58,500 Btu/h
EER2 at 95°F 12.0 12.0–12.2
SEER2 cooling season 15.5 15.5–15.8
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Two-stage
Indoor unit CBK48MVT-060-230-** 2 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified ML16KP2-060-230A**

Pairings, by indoor-unit class

2 indoor units · 2 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 2 indoor units

  1. CBK47UHET-060-230-** brand not stated 27,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 54,500 Btu/h · 95°F cooling 58,500 Btu/h · Cold output 51% · COP 2.10

  2. CBK48MVT-060-230-** (the pairing on screen) brand not stated 27,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 53,500 Btu/h · 95°F cooling 57,500 Btu/h · Cold output 52% · COP 2.10

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CBK47UHET-060-230-** — 27,800 54,500 58,500 51% 2.10 NC 1
CBK48MVT-060-230-** (the pairing on screen) — 27,800 53,500 57,500 52% 2.10 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jul 17, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “ML16KP2-060-230A — certified heat output”. Certified figures dated , checked daily.