Heat Pump List

Tools

7HP19V36P-**A

7HP19V36P-**A is in the certified data.

Its certified full-speed heating output at 5°F is 12,100–17,700 Btu/h, 45–71% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Allied, Breeze33 + 2 more · central heat pump

7HP19V36P-**A is in the certified data as of Sep 19, 2026. 7HP19V36P-**A changed its certified heat output at 47°F on 22 pairings in the certified data between August 2025 and September 2026. The new figure is higher on 8 and lower on 14.

727 certified pairings with 155 different figures. See all

Certified heating and cooling

Heating at 47°F

24,000

15,300 at 17°F

15,100 at 5°F

Btu/h, certified

1.90 COP at 5°F

Cooling at 95°F

22,400

Btu/h, certified

EER2 12.4 at 95°F

SEER2 17.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for 7HP19V36P-**A, by outdoor temperature Heating: 15,100 Btu/h at 5°F, 15,300 Btu/h at 17°F, 24,000 Btu/h at 47°F. Cooling: 22,400 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 15,100 5°F 15,300 17°F 24,000 47°F 22,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 24,000 Btu/h of heat at 47°F, 15,300 Btu/h at 17°F, and 15,100 Btu/h at 5°F, 63% of its 47°F rating. It delivers 22,400 Btu/h of cooling at 95°F. At 5°F that is 3,900 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 12,900 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217464900 · listed by ALLIED · certified Jul 3, 2025 · 8 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 15,1004.43 kW −21% 1.90
17°Ffull speed 15,3004.48 kW −20% NR
47°Fnormal speed 24,0007.03 kW 0% NR
95°Fcooling, full load 22,4006.56 kW — NR

EER2 12.4 in that test. SEER2 17.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.33kW
Electrical input in the 95°F cooling test
1.81kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
15,100 Btu/h
This unit at 5°F median across its pairings
15,100 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 23% of them, at number 436 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for 7HP19V36P-**A

727 pairings · 727 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for 7HP19V36P-**A
This pairingAll pairings
Heating
Heat output at 47°F normal speed 24,000 Btu/h 22,800–36,000 Btu/h
Heat output at 17°F full speed 15,300 Btu/h 13,900–23,000 Btu/h
Heat output at 5°F full speed 15,100 Btu/h 12,100–17,700 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 63%
COP at 5°F full speed 1.90 1.48–2.20
HSPF2 Region IV 8.5 7.8–8.5
Cooling
Cooling capacity at 95°F full-load test 22,400 Btu/h 21,600–35,800 Btu/h
EER2 at 95°F 12.4 11.0–13.2
SEER2 cooling season 17.0 15.2–20.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit 7EH30BX-**+TDR 29 indoor units
Furnace80G1UH070BE12* 64 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold United States US and Canada
Model string as certified 7HP19V36P-**A

Pairings, by indoor-unit class

29 indoor units · 727 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 5 indoor units

  1. 7EH36CX-**+TDR brand not stated 16,400 Btu/hat 5°F, full speed

    58 pairings, 16 with a furnace · 47°F 32,600 Btu/h · 95°F cooling 34,600 Btu/h · Cold output 50% · COP 2.08

  2. 7E[C,U]36BX-**+TDR brand not stated 14,900 Btu/hat 5°F, full speed

    58 pairings, 24 with a furnace · 47°F 32,000 Btu/h · 95°F cooling 34,600 Btu/h · Cold output 46% · COP 1.92

  3. 7E[C,U]36CX-**+TDR brand not stated 14,850 Btu/hat 5°F, full speed

    48 pairings, 16 with a furnace · 47°F 32,100 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 46% · COP 1.94

  4. 7E[C,U]36BX-**+TDR* brand not stated 14,900 Btu/hat 5°F, full speed

    26 pairings, 13 with a furnace · 47°F 32,200 Btu/h · 95°F cooling 34,800 Btu/h · Cold output 46% · COP 1.92

  5. 7EH30AX-**+TDR brand not stated 14,900 Btu/hat 5°F, full speed

    24 pairings, 6 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 23,200 Btu/h · Cold output 63% · COP 1.50

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
7EH36CX-**+TDR — 16,400 32,600 34,600 50% 2.08 NC 58
7E[C,U]36BX-**+TDR — 14,900 32,000 34,600 46% 1.92 NC 58
7E[C,U]36CX-**+TDR — 14,850 32,100 35,000 46% 1.94 NC 48
7E[C,U]36BX-**+TDR* — 14,900 32,200 34,800 46% 1.92 NC 26
7EH30AX-**+TDR — 14,900 23,800 23,200 63% 1.50 NC 24

Air handler · 5 indoor units

  1. 7E[C,U]30BX-**+TDR brand not stated 14,000 Btu/hat 5°F, full speed

    99 pairings, 26 with a furnace · 47°F 23,600 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 59% · COP 1.88

  2. 7E[C,U]24BX-**+TDR brand not stated 16,500 Btu/hat 5°F, full speed

    91 pairings, 24 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 69% · COP 2.02

  3. 7EH30BX-**+TDR (the pairing on screen) brand not stated 15,150 Btu/hat 5°F, full speed

    86 pairings, 23 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 22,400 Btu/h · Cold output 63% · COP 1.88

  4. 7E[C,U]24AX-**+TDR brand not stated 16,400 Btu/hat 5°F, full speed

    43 pairings, 10 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 68% · COP 2.02

  5. 7E[C,U]30AX-**+TDR brand not stated 13,900 Btu/hat 5°F, full speed

    43 pairings, 10 with a furnace · 47°F 23,400 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 59% · COP 1.88

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
7E[C,U]30BX-**+TDR — 14,000 23,600 24,000 59% 1.88 NC 99
7E[C,U]24BX-**+TDR — 16,500 24,000 23,800 69% 2.02 NC 91
7EH30BX-**+TDR (the pairing on screen) — 15,150 24,000 22,400 63% 1.88 NC 86
7E[C,U]24AX-**+TDR — 16,400 24,000 23,600 68% 2.02 NC 43
7E[C,U]30AX-**+TDR — 13,900 23,400 23,800 59% 1.88 NC 43

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 29 indoor units All 727 certified pairings

Sold as, and units with identical certified values

Product history

  • 7HP19V36P-**A changed its certified heat output at 47°F on 22 pairings in the certified data between August 2025 and September 2026. The new figure is higher on 8 and lower on 14.
  • 7HP19V36P-**A changed its certified heat output at 47°F on 2 pairings in the certified data between May 2025 and September 2026. The new figure is lower on all 2.
  • 7HP19V36P-**A changed its certified heat output at 47°F on 3 pairings from 24,000 Btu/h to 23,600 Btu/h in the certified data between June 2025 and September 2026.
  • 7HP19V36P-**A changed its certified heat output at 47°F on at least 101 pairings in the certified data between June 2025 and August 2025. The new figure is higher on 39 and lower on 62.
  • 7HP19V36P-**A first appeared in the certified data between March 2025 and May 2025.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jul 3, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “7HP19V36P-**A — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/7hp19v36p-_st_sta