Heat Pump List

Tools

BH719M36P-**A

BH719M36P-**A is in the certified data.

Its certified full-speed heating output at 5°F is 13,600–17,000 Btu/h, 45–71% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

AC Pro, Blueridge + 1 more · central heat pump

All 118 certified AC Pro models · All 202 certified Blueridge models · All 8 certified Sinclair models

BH719M36P-**A is in the certified data as of Oct 17, 2026. BH719M36P-**A changed its certified heat output at 47°F on 18 pairings in the certified data between August 2025 and September 2026. The new figure is higher on 9 and lower on 9.

420 certified pairings with 120 different figures. See all

Certified heating and cooling

Heating at 47°F

23,000

15,400 at 17°F

15,100 at 5°F

Btu/h, certified

1.90 COP at 5°F

Cooling at 95°F

24,000

Btu/h, certified

EER2 13.2 at 95°F

SEER2 19.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for BH719M36P-**A, by outdoor temperature Heating: 15,100 Btu/h at 5°F, 15,400 Btu/h at 17°F, 23,000 Btu/h at 47°F. Cooling: 24,000 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 15,100 5°F 15,400 17°F 23,000 47°F 24,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 23,000 Btu/h of heat at 47°F, 15,400 Btu/h at 17°F, and 15,100 Btu/h at 5°F, 66% of its 47°F rating. It delivers 24,000 Btu/h of cooling at 95°F. At 5°F that is 3,900 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 14,500 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217547511 · listed by AC PRO · certified Jul 9, 2025 · 3 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 49 programs in 28 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (1), Delaware (2), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Michigan (2), Minnesota (2), Mississippi (2), Nevada (1), New Hampshire (1), New Jersey (7), New York (4), North Carolina (1), Oregon (2), Pennsylvania (4), South Carolina (1), Tennessee (1), Texas (3), Utah (1), Vermont (3), Washington (2), Wisconsin (1), Newfoundland and Labrador (1).

All 49 programs by state and province

Alabama

Arizona

California

Colorado

Delaware

Idaho

Illinois

Kansas

Kentucky

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 15,1004.43 kW −21% 1.90
17°Ffull speed 15,4004.51 kW −20% NR
47°Fnormal speed 23,0006.74 kW −4% NR
95°Fcooling, full load 24,0007.03 kW — NR

EER2 13.2 in that test. SEER2 19.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.33kW
Electrical input in the 95°F cooling test
1.82kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Oct 17, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
15,100 Btu/h
This unit at 5°F median across its pairings
15,100 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 23% of them, at number 436 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 24,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 440th of 565; HSPF2, 423rd of 578 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • MDPH18024D: The same 24,000 Btu/h rating at 47°F; 29,000 Btu/h at 5°F (this model: 15,100).
  • AC024BXUPCH: The same 24,000 Btu/h rating at 47°F; 26,000 Btu/h at 5°F (this model: 15,100).
  • FRP18AZ24AJVC: The same 24,000 Btu/h rating at 47°F; 24,800 Btu/h at 5°F (this model: 15,100).

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 15,100 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42360–630
MildTypical16–26580–940
MildTight, well insulated10–18840–1,510
ColdDrafty, little insulation28–52290–540
ColdTypical18–30500–840
ColdTight, well insulated12–22690–1,260
Very coldDrafty, little insulation32–58260–470
Very coldTypical22–38400–690
Very coldTight, well insulated16–28540–940

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for BH719M36P-**A

420 pairings · 420 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for BH719M36P-**A
This pairingAll pairings
Heating
Heat output at 47°F normal speed 23,000 Btu/h 22,800–36,000 Btu/h
Heat output at 17°F full speed 15,400 Btu/h 14,500–21,600 Btu/h
Heat output at 5°F full speed 15,100 Btu/h 13,600–17,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 66%
COP at 5°F full speed 1.90 1.48–2.12
HSPF2 Region IV 8.5 7.8–8.5
Cooling
Cooling capacity at 95°F full-load test 24,000 Btu/h 21,600–35,800 Btu/h
EER2 at 95°F 13.2 11.0–13.2
SEER2 cooling season 19.5 15.2–20.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit BC736[C,U]BT-**+TDR 21 indoor units
FurnaceB97UR702V3B 51 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified BH719M36P-**A

Across 420 certified pairings with 21 indoor models: heat at 5°F 13,600 Btu/h with BC730[C,U]BT-**+TDR to 17,000 Btu/h with BC724[C,U]AT-**+TDR; HSPF2 7.8 with BC730HAT-**+TDR to 8.5 with BAH7E24PT-**; SEER2 15.2 with BC730HBT-**+TDR to 20.0 with BAH7V30PT-**. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

21 indoor units · 420 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 4 indoor units

  1. BC736[C,U]BT-**+TDR (the pairing on screen) brand not stated 15,000 Btu/hat 5°F, full speed

    51 pairings, 17 with a furnace · 47°F 32,000 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 46% · COP 1.92

  2. BC736[C,U]CT-**+TDR brand not stated 14,850 Btu/hat 5°F, full speed

    42 pairings, 14 with a furnace · 47°F 32,200 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 46% · COP 1.94

  3. BC736HCT-**+TDR brand not stated 16,400 Btu/hat 5°F, full speed

    39 pairings, 13 with a furnace · 47°F 32,600 Btu/h · 95°F cooling 34,600 Btu/h · Cold output 50% · COP 2.08

  4. BC730/36DCT-**+TDR brand not stated 16,400 Btu/hat 5°F, full speed

    12 pairings, 4 with a furnace · 47°F 35,000 Btu/h · 95°F cooling 34,500 Btu/h · Cold output 47% · COP 2.11

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
BC736[C,U]BT-**+TDR (the pairing on screen) — 15,000 32,000 34,400 46% 1.92 NC 51
BC736[C,U]CT-**+TDR — 14,850 32,200 35,000 46% 1.94 NC 42
BC736HCT-**+TDR — 16,400 32,600 34,600 50% 2.08 NC 39
BC730/36DCT-**+TDR — 16,400 35,000 34,500 47% 2.11 NC 12

Air handler · 6 indoor units

  1. BC730[C,U]BT-**+TDR brand not stated 14,000 Btu/hat 5°F, full speed

    57 pairings, 18 with a furnace · 47°F 23,600 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 59% · COP 1.88

  2. BC724[C,U]BT-**+TDR brand not stated 16,550 Btu/hat 5°F, full speed

    54 pairings, 17 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 69% · COP 2.02

  3. BC730HBT-**+TDR brand not stated 15,200 Btu/hat 5°F, full speed

    54 pairings, 17 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 22,400 Btu/h · Cold output 63% · COP 1.88

  4. BC724[C,U]AT-**+TDR brand not stated 16,500 Btu/hat 5°F, full speed

    21 pairings, 6 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 69% · COP 2.02

  5. BC730[C,U]AT-**+TDR brand not stated 14,000 Btu/hat 5°F, full speed

    21 pairings, 6 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 59% · COP 1.88

  6. BC736[C,U]AT-**+TDR brand not stated 14,900 Btu/hat 5°F, full speed

    21 pairings, 6 with a furnace · 47°F 32,200 Btu/h · 95°F cooling 34,400 Btu/h · Cold output 46% · COP 1.90

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
BC730[C,U]BT-**+TDR — 14,000 23,600 24,000 59% 1.88 NC 57
BC724[C,U]BT-**+TDR — 16,550 24,000 24,000 69% 2.02 NC 54
BC730HBT-**+TDR — 15,200 24,000 22,400 63% 1.88 NC 54
BC724[C,U]AT-**+TDR — 16,500 24,000 23,800 69% 2.02 NC 21
BC730[C,U]AT-**+TDR — 14,000 23,800 24,000 59% 1.88 NC 21
BC736[C,U]AT-**+TDR — 14,900 32,200 34,400 46% 1.90 NC 21

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 21 indoor units All 420 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • BH719M36P-**A changed its certified heat output at 47°F on 18 pairings in the certified data between August 2025 and September 2026. The new figure is higher on 9 and lower on 9.
  • BH719M36P-**A first appeared in the certified data between June 2025 and August 2025.

History and definitions

Other BH719M SERIES models by nominal cooling size: BH719M60P-**A (48,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Jul 9, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “BH719M36P-**A — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/bh719m36p-_st_sta