Heat Pump List

Tools

EL17XP1-030-230A

Lennox · central heat pump

All 152 certified Lennox models

EL17XP1-030-230A is in the certified data as of Sep 27, 2026. EL17XP1-030-230A changed its certified heat output at 17°F on 4 pairings in the certified data between September 2024 and November 2024. The new figure is higher on all 4.

448 certified pairings with 131 different figures. See all

Certified heating and cooling

Heating at 47°F

27,600

18,200 at 17°F

14,400 at 5°F

Btu/h, certified

2.28 COP at 5°F

Cooling at 95°F

29,400

Btu/h, certified

EER2 13.0 at 95°F

SEER2 16.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for EL17XP1-030-230A, by outdoor temperature Heating: 14,400 Btu/h at 5°F, 18,200 Btu/h at 17°F, 27,600 Btu/h at 47°F. Cooling: 29,400 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton central models: 22,400 Btu/h at 5°F, 20,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 14,400 5°F 18,200 17°F 27,600 47°F 29,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 27,600 Btu/h of heat at 47°F, 18,200 Btu/h at 17°F, and 14,400 Btu/h at 5°F, 52% of its 47°F rating. It delivers 29,400 Btu/h of cooling at 95°F. At 5°F that is 8,100 Btu/h short of the example heating load of 22,500 Btu/h; at 95°F it is 17,900 Btu/h above the example cooling load of 11,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 210291611 · listed by Lennox · certified Oct 27, 2025 · 12 pairings share these values

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 14,4004.22 kW −36% 2.28
17°Fone compressor speed 18,2005.33 kW −12% NR
47°Fone compressor speed 27,6008.09 kW −8% NR
95°Fcooling, full load 29,4008.62 kW — NR

EER2 13.0 in that test. SEER2 16.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.85kW
Electrical input in the 95°F cooling test
2.26kW
Seasonal average heating COP
2.37

These exclude backup resistance heat.

Updated Sep 27, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton central models

This pairing at 5°F
14,400 Btu/h
This unit at 5°F median across its pairings
14,400 Btu/h
Median of 2.5-ton central models at 5°F
22,400 Btu/h
Models in this group
288

This unit is above 25% of them, at number 215 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 30,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 204th of 288 (tied); HSPF2, 177th of 290 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • (C,H,T)4H5S30*K*AAA*: The same 28,000 Btu/h rating at 47°F; 10,000 Btu/h at 5°F (this model: 14,400).
  • GH5SAN430**AA*: The same 28,000 Btu/h rating at 47°F; 12,900 Btu/h at 5°F (this model: 14,400).
  • WFPU18Z363C: 28,200 Btu/h at 47°F (this model: 28,000); 23,200 Btu/h at 5°F (this model: 14,400).

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 14,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42340–600
MildTypical16–26550–900
MildTight, well insulated10–18800–1,440
ColdDrafty, little insulation28–52280–510
ColdTypical18–30480–800
ColdTight, well insulated12–22650–1,200
Very coldDrafty, little insulation32–58250–450
Very coldTypical22–38380–650
Very coldTight, well insulated16–28510–900

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for EL17XP1-030-230A

448 pairings · 448 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for EL17XP1-030-230A
This pairingAll pairings
Heating
Heat output at 47°F one speed 27,600 Btu/h 26,600–30,000 Btu/h
Heat output at 17°F full speed 18,200 Btu/h 17,200–19,600 Btu/h
Heat output at 5°F full speed 14,400 Btu/h 13,200–15,400 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 52%
COP at 5°F full speed 2.28 1.96–2.38
HSPF2 Region IV 8.1 7.8–8.6
Cooling
Cooling capacity at 95°F full-load test 29,400 Btu/h 28,200–30,600 Btu/h
EER2 at 95°F 13.0 12.2–13.5
SEER2 cooling season 16.0 15.2–16.2
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Single stage
Indoor unit C35-36A+TDR+TXV 36 indoor units
FurnaceML180UH045E36A* 95 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold United States US and Canada
Model string as certified EL17XP1-030-230A**

Across 448 certified pairings with 36 indoor models: heat at 5°F 13,200 Btu/h with CBA25UHE-036-230-** to 15,400 Btu/h with CK40DT-42B-0*+TDR; HSPF2 7.8 with C35-30A+TDR+TXV to 8.6 with CK40DT-42B-0*+TDR; SEER2 15.2 with C35-30B+TDR+TXV to 16.2 with C35-36A+TDR+TXV. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

36 indoor units · 448 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. C35-36B+TDR+TXV brand not stated 14,400 Btu/hat 5°F, full speed

    33 pairings, 33 with a furnace · 47°F 27,800 Btu/h · 95°F cooling 29,600 Btu/h · Cold output 51% · COP 2.26

  2. CHX35-30B-**-*+TDR brand not stated 13,700 Btu/hat 5°F, full speed

    33 pairings, 33 with a furnace · 47°F 27,800 Btu/h · 95°F cooling 29,400 Btu/h · Cold output 49% · COP 2.08

  3. CHX35-36C-**-*+TDR brand not stated 14,700 Btu/hat 5°F, full speed

    33 pairings, 33 with a furnace · 47°F 28,400 Btu/h · 95°F cooling 29,000 Btu/h · Cold output 52% · COP 2.22

  4. CK40HT-30B-0*+TDR brand not stated 13,700 Btu/hat 5°F, full speed

    33 pairings, 33 with a furnace · 47°F 27,800 Btu/h · 95°F cooling 29,400 Btu/h · Cold output 49% · COP 2.08

  5. CK40HT-36C-0*+TDR brand not stated 14,700 Btu/hat 5°F, full speed

    33 pairings, 33 with a furnace · 47°F 28,400 Btu/h · 95°F cooling 29,000 Btu/h · Cold output 52% · COP 2.22

  6. CX35-36B+TDR brand not stated 14,400 Btu/hat 5°F, full speed

    33 pairings, 33 with a furnace · 47°F 27,800 Btu/h · 95°F cooling 29,600 Btu/h · Cold output 51% · COP 2.26

  7. C35-30B+TDR+TXV brand not stated 14,400 Btu/hat 5°F, full speed

    30 pairings, 30 with a furnace · 47°F 27,800 Btu/h · 95°F cooling 28,800 Btu/h · Cold output 52% · COP 2.20

  8. CX35-30B+TDR brand not stated 14,400 Btu/hat 5°F, full speed

    30 pairings, 30 with a furnace · 47°F 27,800 Btu/h · 95°F cooling 28,800 Btu/h · Cold output 52% · COP 2.20

  9. CK40CT-36B-0*+TDR brand not stated 14,400 Btu/hat 5°F, full speed

    29 pairings, 29 with a furnace · 47°F 28,000 Btu/h · 95°F cooling 29,800 Btu/h · Cold output 51% · COP 2.26

  10. CK40DT-42B-0*+TDR brand not stated 15,300 Btu/hat 5°F, full speed

    15 pairings, 15 with a furnace · 47°F 30,000 Btu/h · 95°F cooling 29,800 Btu/h · Cold output 51% · COP 2.32

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
C35-36B+TDR+TXV — 14,400 27,800 29,600 51% 2.26 NC 33
CHX35-30B-**-*+TDR — 13,700 27,800 29,400 49% 2.08 NC 33
CHX35-36C-**-*+TDR — 14,700 28,400 29,000 52% 2.22 NC 33
CK40HT-30B-0*+TDR — 13,700 27,800 29,400 49% 2.08 NC 33
CK40HT-36C-0*+TDR — 14,700 28,400 29,000 52% 2.22 NC 33
CX35-36B+TDR — 14,400 27,800 29,600 51% 2.26 NC 33
C35-30B+TDR+TXV — 14,400 27,800 28,800 52% 2.20 NC 30
CX35-30B+TDR — 14,400 27,800 28,800 52% 2.20 NC 30
CK40CT-36B-0*+TDR — 14,400 28,000 29,800 51% 2.26 NC 29
CK40DT-42B-0*+TDR — 15,300 30,000 29,800 51% 2.32 NC 15

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 36 indoor units All 448 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

2 of 3 shown.

Product history

  • EL17XP1-030-230A changed its certified heat output at 17°F on 4 pairings in the certified data between September 2024 and November 2024. The new figure is higher on all 4.
  • EL17XP1-030-230A was in the certified data by September 2024.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Oct 27, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “EL17XP1-030-230A — certified heat output”. Certified figures dated , checked daily.