GWHD(30)ND3NO
GWHD(30)ND3NO is in the certified data.
Its certified full-speed heating output at 5°F is 22,800–26,800 Btu/h6.68–7.85 kW, 76–89% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Gree · mini-split heat pump
GWHD(30)ND3NO is in the certified data as of Sep 19, 2026.
- 30,000 Btu (2.5-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
30,0008.79NR
No 47°F rating for this pairing.
27,0007.91NR at 17°F
24,8007.27NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 30,000 Btu/h8.79 kW of heat at 47°F, 27,000 Btu/h7.91 kW at 17°F, and 24,800 Btu/h7.27 kW at 5°F, 83% of its 47°F rating. It delivers 28,400 Btu/h8.32 kW of cooling at 95°F. At 5°F that is 200 Btu/h0.06 kW short of the example heating load of 25,000 Btu/h7.33 kW; at 95°F it is 15,900 Btu/h4.66 kW above the example cooling load of 12,500 Btu/h3.66 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h7.33 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h3.66 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210485374 · listed by GREE · certified Jun 13, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 11 programs in 7 states, provinces, or territories:British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 11 programs by state and province
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 24,8007.27 kW | −1% | 1.80 | |
| 17°Ffull speed | 27,0007.91 kW | +5% | NR | |
| 47°Fnormal speed | 30,0008.79 kW | 0% | NR | |
| 95°Fcooling, full load | 28,4008.32 kW | — | NR |
EER2 11.75 in that test. SEER2 18.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.04kW
- Electrical input in the 95°F cooling test
- 2.42kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton mini-split models
- This pairing at 5°F
- 24,800 Btu/h7.27 kWNR
- This unit at 5°F median across its pairings
- 24,800 Btu/h7.27 kW
- Median of 2.5-ton mini-split models at 5°F
- 25,000 Btu/h7.33 kW
- Models in this group
- 405
This unit is above 45% of them, at number 223 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.
Among 30,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 204th of 405 (tied); HSPF2, 275th of 405 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- AOUH30LUAH1: The same 30,000 Btu/h rating at 47°F; 33,000 Btu/h at 5°F (this model: 24,800).
- AOD30-30HFN1-MS0W: The same 30,000 Btu/h rating at 47°F; 17,500 Btu/h at 5°F (this model: 24,800).
- ADSZ130DA: The same 30,000 Btu/h rating at 47°F; 18,000 Btu/h at 5°F (this model: 24,800).
Closest models by heat at 5°F
- MLB030S4M-1PLennox · 25,000 Btu/h
- MST283G22MHAAGoodman · 25,000 Btu/h
- NDHAM-28-ONapoleon · 25,000 Btu/h
- TM30HX4OTosot · 24,800 Btu/h
- 38MGHBQ30DA3Bryant, Carrier + 3 more · 24,600 Btu/h
- AM4-H30/2DR3AAUX · 24,600 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 24,800 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 590–1,030 |
| Mild | Typical | 16–26 | 950–1,550 |
| Mild | Tight, well insulated | 10–18 | 1,380–2,480 |
| Cold | Drafty, little insulation | 28–52 | 480–890 |
| Cold | Typical | 18–30 | 830–1,380 |
| Cold | Tight, well insulated | 12–22 | 1,130–2,070 |
| Very cold | Drafty, little insulation | 32–58 | 430–780 |
| Very cold | Typical | 22–38 | 650–1,130 |
| Very cold | Tight, well insulated | 16–28 | 890–1,550 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for GWHD(30)ND3NO
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 30,000 Btu/h8.79 kWNR | 30,000 Btu/h8.79 kW |
| Heat output at 17°F full speed | 27,000 Btu/h7.91 kWNR | 26,800–27,200 Btu/h7.85–7.97 kW |
| Heat output at 5°F full speed | 24,800 Btu/h7.27 kWNR | 22,800–26,800 Btu/h6.68–7.85 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 83%NR | |
| COP at 5°F full speed | 1.80NR | 1.80–1.84 |
| HSPF2 Region IV | 9.0NR | 8.1–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 28,400 Btu/h8.32 kWNR | 28,400 Btu/h8.32 kW |
| EER2 at 95°F | 11.75NR | 11.0–12.5 |
| SEER2 cooling season | 18.5NR | 16.0–19.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | Canada | Canada |
| Model string as certified | GWHD(30)ND3NO | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) GREE 24,800 Btu/h7.27 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | GREE | 24,8007.27 | 30,0008.79 | 28,4008.32 | 83% | 1.80 | Yes | 3 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other M-Series models by nominal cooling size: GS2M18HP230V1MO (18,000 Btu), GWHD(18)ND3NO (18,000 Btu), MUL19HP230V1R32AO (18,000 Btu), GS3M24HP230V1MO (24,000 Btu), GWHD(24)ND3NO (24,000 Btu), GS4M30HP230V1MO (30,000 Btu), GS4M36HP230V1MO (36,000 Btu), GWHD(36)ND3NO (36,000 Btu); more models from this brand.
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read