Heat Pump List

Tools

GZV7SA3610A

GZV7SA3610A is in the certified data.

Its certified full-speed heating output at 5°F is 28,000–29,000 Btu/h, 80–83% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Goodman · central heat pump

All 59 certified Goodman models

GZV7SA3610A is in the certified data as of Sep 19, 2026.

69 certified pairings with 10 different figures. See all

Certified heating and cooling

Heating at 47°F

35,000

22,000 at 17°F

28,400 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

34,800

Btu/h, certified

EER2 10.5 at 95°F

SEER2 18.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for GZV7SA3610A, by outdoor temperature Heating: 28,400 Btu/h at 5°F, 22,000 Btu/h at 17°F, 35,000 Btu/h at 47°F. Cooling: 34,800 Btu/h at 95°F. The bars start at zero. Median of 3-ton central models: 26,400 Btu/h at 5°F, 26,200 Btu/h at 17°F, 35,200 Btu/h at 47°F, 35,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 28,400 5°F 22,000 17°F 35,000 47°F 34,800 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 35,000 Btu/h of heat at 47°F, 22,000 Btu/h at 17°F, and 28,400 Btu/h at 5°F, 81% of its 47°F rating. It delivers 34,800 Btu/h of cooling at 95°F. At 5°F that is 1,900 Btu/h above the example heating load of 26,500 Btu/h; at 95°F it is 21,800 Btu/h above the example cooling load of 13,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 215429743 · listed by Goodman · certified Jan 6, 2026 · 20 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 59 programs in 37 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (1), Connecticut (3), Delaware (1), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (3), New York (4), North Carolina (1), Oregon (2), Pennsylvania (1), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (1), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 59 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Delaware

Idaho

Illinois

Kansas

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 28,4008.32 kW +8% 2.00
17°Ffull speed 22,0006.45 kW −16% NR
47°Fnormal speed 35,00010.26 kW −1% NR
95°Fcooling, full load 34,80010.20 kW — NR

EER2 10.5 in that test. SEER2 18.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
4.16kW
Electrical input in the 95°F cooling test
3.31kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton central models

This pairing at 5°F
28,400 Btu/h
This unit at 5°F median across its pairings
28,400 Btu/h
Median of 3-ton central models at 5°F
26,400 Btu/h
Models in this group
451

This unit is above 58% of them, at number 191 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 36,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 167th of 451 (tied); HSPF2, 222nd of 467 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • 25SCA536A**30*: The same 35,000 Btu/h rating at 47°F; 16,500 Btu/h at 5°F (this model: 28,400).
  • GH5SAN536**AA*: The same 35,000 Btu/h rating at 47°F; 17,500 Btu/h at 5°F (this model: 28,400).
  • GLZS5BA3610A: The same 35,000 Btu/h rating at 47°F; 17,600 Btu/h at 5°F (this model: 28,400).

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 28,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42680–1,180
MildTypical16–261,090–1,780
MildTight, well insulated10–181,580–2,840
ColdDrafty, little insulation28–52550–1,010
ColdTypical18–30950–1,580
ColdTight, well insulated12–221,290–2,370
Very coldDrafty, little insulation32–58490–890
Very coldTypical22–38750–1,290
Very coldTight, well insulated16–281,010–1,780

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for GZV7SA3610A

69 pairings · 69 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for GZV7SA3610A
This pairingAll pairings
Heating
Heat output at 47°F normal speed 35,000 Btu/h 34,800–35,000 Btu/h
Heat output at 17°F full speed 22,000 Btu/h 22,000 Btu/h
Heat output at 5°F full speed 28,400 Btu/h 28,000–29,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 81%
COP at 5°F full speed 2.00 2.00
HSPF2 Region IV 8.5 8.1–8.8
Cooling
Cooling capacity at 95°F full-load test 34,800 Btu/h 34,000–35,000 Btu/h
EER2 at 95°F 10.5 10.0–10.5
SEER2 cooling season 18.5 15.2–19.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-32
Compressor Variable speed
Indoor unit AHVE42CP1300A* 25 indoor units
FurnaceNo furnace 25 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified GZV7SA3610A*

Across 69 certified pairings with 25 indoor models: heat at 5°F 28,000 Btu/h with CA*EA4830*3A*+D24V to 29,000 Btu/h with AHVE48DP0300A*; HSPF2 8.1 with CA*EA4830*3A* to 8.8 with AHVE48DP0300A*; SEER2 15.2 with CA*EA4830*3A*+D24V to 19.0 with AHVE48DP0300A*. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

25 indoor units · 69 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 3 indoor units

  1. CA*EA4830*3A* brand not stated 28,400 Btu/hat 5°F, full speed

    25 pairings, 25 with a furnace · 47°F 35,000 Btu/h · 95°F cooling 34,800 Btu/h · Cold output 81% · COP 2.00

  2. CHPEA4830*3A* brand not stated 28,400 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  3. CA*EA6030*3A* brand not stated 28,400 Btu/hat 5°F, full speed

    6 pairings, 6 with a furnace · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CA*EA4830*3A* — 28,400 35,000 34,800 81% 2.00 Yes 25
CHPEA4830*3A* — 28,400 35,000 35,000 81% 2.00 Yes 16
CA*EA6030*3A* — 28,400 35,000 35,000 81% 2.00 Yes 6

Air handler · 22 indoor units

  1. AHVE42CP0300A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 34,800 Btu/h · Cold output 81% · COP 2.00

  2. AHVE42CP1300A* (the pairing on screen) brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 34,800 Btu/h · Cold output 81% · COP 2.00

  3. AHVE48CP0300A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 34,800 Btu/h · Cold output 81% · COP 2.00

  4. AHVE48CP1300A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 34,800 Btu/h · Cold output 81% · COP 2.00

  5. AHVE48DP0300A* brand not stated 29,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 83% · COP 2.00

  6. AHVE48DP1300A* brand not stated 29,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 83% · COP 2.00

  7. AHVE60DP0300A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  8. AHVE60DP1300A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  9. CA*EA4830*3A*+D24V brand not stated 28,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 34,800 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 80% · COP 2.00

  10. CA*EA4830*3A*+MBVK16CP0X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  11. CA*EA4830*3A*+MBVK16CP1X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  12. CA*EA4830*3A*+MBVK20DP0X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  13. CA*EA4830*3A*+MBVK20DP1X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  14. CA*EA6030*3A*+D24V brand not stated 28,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 34,800 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 80% · COP 2.00

  15. CA*EA6030*3A*+MBVK16CP0X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  16. CA*EA6030*3A*+MBVK16CP1X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  17. CA*EA6030*3A*+MBVK20DP0X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  18. CA*EA6030*3A*+MBVK20DP1X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  19. CHPEA4830*3A*+MBVK16CP0X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

  20. CHPEA4830*3A*+MBVK16CP1X00A* brand not stated 28,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 81% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
AHVE42CP0300A* — 28,400 35,000 34,800 81% 2.00 Yes 1
AHVE42CP1300A* (the pairing on screen) — 28,400 35,000 34,800 81% 2.00 Yes 1
AHVE48CP0300A* — 28,400 35,000 34,800 81% 2.00 Yes 1
AHVE48CP1300A* — 28,400 35,000 34,800 81% 2.00 Yes 1
AHVE48DP0300A* — 29,000 35,000 35,000 83% 2.00 Yes 1
AHVE48DP1300A* — 29,000 35,000 35,000 83% 2.00 Yes 1
AHVE60DP0300A* — 28,400 35,000 35,000 81% 2.00 Yes 1
AHVE60DP1300A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CA*EA4830*3A*+D24V — 28,000 34,800 34,000 80% 2.00 Yes 1
CA*EA4830*3A*+MBVK16CP0X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CA*EA4830*3A*+MBVK16CP1X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CA*EA4830*3A*+MBVK20DP0X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CA*EA4830*3A*+MBVK20DP1X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CA*EA6030*3A*+D24V — 28,000 34,800 34,000 80% 2.00 Yes 1
CA*EA6030*3A*+MBVK16CP0X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CA*EA6030*3A*+MBVK16CP1X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CA*EA6030*3A*+MBVK20DP0X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CA*EA6030*3A*+MBVK20DP1X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CHPEA4830*3A*+MBVK16CP0X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1
CHPEA4830*3A*+MBVK16CP1X00A* — 28,400 35,000 35,000 81% 2.00 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 23 of 25 indoor units All 69 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

2 of 3 shown.

Other model numbers with identical certified values

3 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

2 of 3 shown.

History and definitions

Other GZV7SA models by nominal cooling size: GZV7SA2410A (24,000 Btu), GZV7SA4210A (42,000 Btu), GZV7SA4810A (48,000 Btu), GZV7SA6010A (54,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Jan 6, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “GZV7SA3610A — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/gzv7sa3610a