Heat Pump List

Tools

GH5SAN536**AA*

GH5SAN536**AA* is in the certified data.

Its certified full-speed heating output at 5°F is 16,100–18,100 Btu/h, 48–54% of its 47°F rating, depending on the pairing.

Bryant and Carrier · central heat pump

All 205 certified Bryant models · All 187 certified Carrier models

GH5SAN536**AA* is in the certified data as of Sep 19, 2026. GH5SAN536**AA* changed its certified COP at 5°F on 8 pairings in the certified data between June 2025 and August 2025. The new figure is lower on all 8.

63 certified pairings with 25 different figures. See all

Certified heating and cooling

Heating at 47°F

33,800

22,000 at 17°F

17,500 at 5°F

Btu/h, certified

2.18 COP at 5°F

Cooling at 95°F

34,400

Btu/h, certified

EER2 12.0 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for GH5SAN536**AA*, by outdoor temperature Heating: 17,500 Btu/h at 5°F, 22,000 Btu/h at 17°F, 33,800 Btu/h at 47°F. Cooling: 34,400 Btu/h at 95°F. The bars start at zero. Median of 3-ton central models: 26,400 Btu/h at 5°F, 26,200 Btu/h at 17°F, 35,200 Btu/h at 47°F, 35,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 17,500 5°F 22,000 17°F 33,800 47°F 34,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 33,800 Btu/h of heat at 47°F, 22,000 Btu/h at 17°F, and 17,500 Btu/h at 5°F, 52% of its 47°F rating. It delivers 34,400 Btu/h of cooling at 95°F. At 5°F that is 9,000 Btu/h short of the example heating load of 26,500 Btu/h; at 95°F it is 21,400 Btu/h above the example cooling load of 13,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214141449 · listed by Carrier · certified Jul 3, 2025 · 4 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 27 programs in 17 states, provinces, or territories:California (1), Colorado (1), Idaho (1), Kansas (1), Maryland (3), Michigan (2), Minnesota (2), Mississippi (1), Nevada (1), New Jersey (4), North Carolina (1), Oregon (2), Pennsylvania (3), South Carolina (1), Texas (3), Utah (1), Newfoundland and Labrador (1).

All 27 programs by state and province

California

Colorado

Idaho

Kansas

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Jersey

North Carolina

Oregon

Pennsylvania

South Carolina

Texas

Utah

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 17,5005.13 kW −34% 2.18
17°Fone compressor speed 22,0006.45 kW −16% NR
47°Fone compressor speed 33,8009.91 kW −4% NR
95°Fcooling, full load 34,40010.08 kW — NR

EER2 12.0 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.35kW
Electrical input in the 95°F cooling test
2.87kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton central models

This pairing at 5°F
17,500 Btu/h
This unit at 5°F median across its pairings
17,500 Btu/h
Median of 3-ton central models at 5°F
26,400 Btu/h
Models in this group
451

This unit is above 13% of them, at number 393 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 36,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 409th of 451 (tied); HSPF2, 363rd of 467 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • AC036FCUPCG: The same 35,000 Btu/h rating at 47°F; 37,600 Btu/h at 5°F (this model: 17,500).
  • YH936E2C11: The same 35,000 Btu/h rating at 47°F; 32,600 Btu/h at 5°F (this model: 17,500).
  • GZV7SA3610A: The same 35,000 Btu/h rating at 47°F; 28,400 Btu/h at 5°F (this model: 17,500).

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 17,500 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42420–730
MildTypical16–26670–1,090
MildTight, well insulated10–18970–1,750
ColdDrafty, little insulation28–52340–630
ColdTypical18–30580–970
ColdTight, well insulated12–22800–1,460
Very coldDrafty, little insulation32–58300–550
Very coldTypical22–38460–800
Very coldTight, well insulated16–28630–1,090

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for GH5SAN536**AA*

63 pairings · 63 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for GH5SAN536**AA*
This pairingAll pairings
Heating
Heat output at 47°F one speed 33,800 Btu/h 33,200–36,400 Btu/h
Heat output at 17°F full speed 22,000 Btu/h 21,000–22,800 Btu/h
Heat output at 5°F full speed 17,500 Btu/h 16,100–18,100 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 52%
COP at 5°F full speed 2.18 2.00–2.22
HSPF2 Region IV 7.8 7.8–8.0
Cooling
Cooling capacity at 95°F full-load test 34,400 Btu/h 33,800–36,800 Btu/h
EER2 at 95°F 12.0 11.7–13.0
SEER2 cooling season 15.2 15.2–16.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Single stage
Indoor unit CAA**4821AM* 19 indoor units
Furnace58SP*B090V21**20 28 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified GH5SAN536**AA*

Across 63 certified pairings with 19 indoor models: heat at 5°F 16,100 Btu/h with F55AA*C42L* to 18,100 Btu/h with CVAMA4421XMA*; HSPF2 7.8 with CAA**3721AM* to 8.0 with FEVA0048**+NAVA54801CK; SEER2 15.2 with CAA**3721AM* to 16.0 with FEVA0048**+NAVA54801CK. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

19 indoor units · 63 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 5 indoor units

  1. CAA**4821AM* (the pairing on screen) brand not stated 17,500 Btu/hat 5°F, full speed

    20 pairings, 20 with a furnace · 47°F 33,600 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 52% · COP 2.18

  2. CAA**4321AM* brand not stated 17,900 Btu/hat 5°F, full speed

    10 pairings, 10 with a furnace · 47°F 34,200 Btu/h · 95°F cooling 34,800 Btu/h · Cold output 52% · COP 2.20

  3. CAA**3721AM* brand not stated 17,500 Btu/hat 5°F, full speed

    4 pairings, 4 with a furnace · 47°F 34,600 Btu/h · 95°F cooling 34,900 Btu/h · Cold output 51% · COP 2.18

  4. CVAMA4421XMA* brand not stated 18,100 Btu/hat 5°F, full speed

    2 pairings, 2 with a furnace · 47°F 35,800 Btu/h · 95°F cooling 36,400 Btu/h · Cold output 51% · COP 2.14

  5. CVAVA4224XMA* brand not stated 18,100 Btu/hat 5°F, full speed

    2 pairings, 2 with a furnace · 47°F 36,200 Btu/h · 95°F cooling 36,800 Btu/h · Cold output 50% · COP 2.14

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CAA**4821AM* (the pairing on screen) — 17,500 33,600 34,200 52% 2.18 NC 20
CAA**4321AM* — 17,900 34,200 34,800 52% 2.20 NC 10
CAA**3721AM* — 17,500 34,600 34,900 51% 2.18 NC 4
CVAMA4421XMA* — 18,100 35,800 36,400 51% 2.14 NC 2
CVAVA4224XMA* — 18,100 36,200 36,800 50% 2.14 NC 2

Air handler · 5 indoor units

  1. F55AA*C42L* brand not stated 16,100 Btu/hat 5°F, full speed

    2 pairings · 47°F 33,800 Btu/h · 95°F cooling 34,800 Btu/h · Cold output 48% · COP 2.02

  2. F55AA*C48L* brand not stated 17,400 Btu/hat 5°F, full speed

    2 pairings · 47°F 35,200 Btu/h · 95°F cooling 36,400 Btu/h · Cold output 49% · COP 2.18

  3. FEVA0048**+NAVA54801CK brand not stated 17,400 Btu/hat 5°F, full speed

    2 pairings · 47°F 36,400 Btu/h · 95°F cooling 36,800 Btu/h · Cold output 48% · COP 2.18

  4. FEVB0048**+NAVA54801CK brand not stated 17,400 Btu/hat 5°F, full speed

    2 pairings · 47°F 36,200 Btu/h · 95°F cooling 36,400 Btu/h · Cold output 48% · COP 2.22

  5. FG5ANXC48L* brand not stated 16,700 Btu/hat 5°F, full speed

    2 pairings · 47°F 35,000 Btu/h · 95°F cooling 35,000 Btu/h · Cold output 48% · COP 2.18

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
F55AA*C42L* — 16,100 33,800 34,800 48% 2.02 NC 2
F55AA*C48L* — 17,400 35,200 36,400 49% 2.18 NC 2
FEVA0048**+NAVA54801CK — 17,400 36,400 36,800 48% 2.18 NC 2
FEVB0048**+NAVA54801CK — 17,400 36,200 36,400 48% 2.22 NC 2
FG5ANXC48L* — 16,700 35,000 35,000 48% 2.18 NC 2

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 19 indoor units All 63 certified pairings

Sold as, and units with identical certified values

Product history

  • GH5SAN536**AA* changed its certified COP at 5°F on 8 pairings in the certified data between June 2025 and August 2025. The new figure is lower on all 8.
  • GH5SAN536**AA* changed its certified heat output at 5°F on 10 pairings in the certified data between June 2025 and August 2025. The new figure is lower on all 10.
  • GH5SAN536**AA* changed its certified heat output at 17°F on 11 pairings in the certified data between June 2025 and August 2025. The new figure is higher on 4 and lower on 7.
  • GH5SAN536**AA* was in the certified data by September 2024.

History and definitions

Other 15 SEER2 HP models by nominal cooling size: GH5SAN518**AA* (18,000 Btu), GH5SAN519**AA* (18,000 Btu), GH5SAN524**AA* (24,000 Btu), GH5SAN430**AA* (30,000 Btu), GH5SAN530**AA* (30,000 Btu), GH5SAN531**AA* (30,000 Btu), PH5SAN430**AA* (30,000 Btu), GH5SAN436**AA* (36,000 Btu); more models from this brand.

Other 15 SEER2 HP models by nominal cooling size: GH5SAN418**AA* (18,000 Btu), GH5SAN518**AA* (18,000 Btu), GH5SAN519**AA* (18,000 Btu), GH5SAN524**AA* (24,000 Btu), GH5SAN430**AA* (30,000 Btu), GH5SAN530**AA* (30,000 Btu), GH5SAN531**AA* (30,000 Btu), GH5SAN436**AA* (36,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Jul 3, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “GH5SAN536**AA* — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/gh5san536_st_staa_st