Heat Pump List

Tools

N5HP5036A1

N5HP5036A1 is in the certified data.

Its certified full-speed heating output at 5°F is 17,100–17,800 Btu/h, 56–59% of its 47°F rating, depending on the pairing.

American Standard and Trane · central heat pump

All 88 certified American Standard models · All 104 certified Trane models

N5HP5036A1 is in the certified data as of Sep 19, 2026.

166 certified pairings with 56 different figures. See all

Certified heating and cooling

Heating at 47°F

29,800

21,600 at 17°F

17,500 at 5°F

Btu/h, certified

2.33 COP at 5°F

Cooling at 95°F

32,400

Btu/h, certified

EER2 11.7 at 95°F

SEER2 15.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for N5HP5036A1, by outdoor temperature Heating: 17,500 Btu/h at 5°F, 21,600 Btu/h at 17°F, 29,800 Btu/h at 47°F. Cooling: 32,400 Btu/h at 95°F. The bars start at zero. Median of 3-ton central models: 26,400 Btu/h at 5°F, 26,200 Btu/h at 17°F, 35,200 Btu/h at 47°F, 35,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 17,500 5°F 21,600 17°F 29,800 47°F 32,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 29,800 Btu/h of heat at 47°F, 21,600 Btu/h at 17°F, and 17,500 Btu/h at 5°F, 59% of its 47°F rating. It delivers 32,400 Btu/h of cooling at 95°F. At 5°F that is 9,000 Btu/h short of the example heating load of 26,500 Btu/h; at 95°F it is 19,400 Btu/h above the example cooling load of 13,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218469614 · listed by Trane · certified Jun 29, 2026 · 4 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 32 programs in 20 states, provinces, or territories:California (2), Colorado (1), Idaho (2), Illinois (1), Kansas (1), Maryland (3), Michigan (2), Minnesota (2), Mississippi (1), Nevada (1), New Hampshire (1), New Jersey (4), North Carolina (1), Oregon (2), Pennsylvania (3), South Carolina (1), Texas (3), Utah (1), Washington (2), Wisconsin (1).

All 32 programs by state and province

California

Colorado

Idaho

Illinois

Kansas

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

North Carolina

Oregon

Pennsylvania

South Carolina

Texas

Utah

Washington

Wisconsin

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 17,5005.13 kW −34% 2.33
17°Fone compressor speed 21,6006.33 kW −18% NR
47°Fone compressor speed 29,8008.73 kW −15% NR
95°Fcooling, full load 32,4009.50 kW — NR

EER2 11.7 in that test. SEER2 15.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.20kW
Electrical input in the 95°F cooling test
2.77kW
Seasonal average heating COP
2.37

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton central models

This pairing at 5°F
17,500 Btu/h
This unit at 5°F median across its pairings
17,500 Btu/h
Median of 3-ton central models at 5°F
26,400 Btu/h
Models in this group
451

This unit is above 13% of them, at number 393 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 36,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 319th of 451; HSPF2, 313th of 467 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • 4A6V8X36A1: 31,000 Btu/h at 47°F (this model: 30,200); 20,400 Btu/h at 5°F (this model: 17,500).
  • SL22KLV-036-230A: 31,400 Btu/h at 47°F (this model: 30,200); 27,200 Btu/h at 5°F (this model: 17,500).
  • HH836E2S11: 31,600 Btu/h at 47°F (this model: 30,200); 25,400 Btu/h at 5°F (this model: 17,500).

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 17,500 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42420–730
MildTypical16–26670–1,090
MildTight, well insulated10–18970–1,750
ColdDrafty, little insulation28–52340–630
ColdTypical18–30580–970
ColdTight, well insulated12–22800–1,460
Very coldDrafty, little insulation32–58300–550
Very coldTypical22–38460–800
Very coldTight, well insulated16–28630–1,090

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for N5HP5036A1

166 pairings · 166 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for N5HP5036A1
This pairingAll pairings
Heating
Heat output at 47°F one speed 29,800 Btu/h 29,600–31,200 Btu/h
Heat output at 17°F full speed 21,600 Btu/h 21,400–22,400 Btu/h
Heat output at 5°F full speed 17,500 Btu/h 17,100–17,800 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 59%
COP at 5°F full speed 2.33 2.29–2.48
HSPF2 Region IV 8.1 8.1
Cooling
Cooling capacity at 95°F full-load test 32,400 Btu/h 32,200–35,000 Btu/h
EER2 at 95°F 11.7 11.7–12.0
SEER2 cooling season 15.5 15.2–16.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Single stage
Indoor unit 5PX*C005AS3+TSTAT 34 indoor units
FurnaceA951X080CU5SA 25 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold United States United States
Model string as certified N5HP5036A1

Across 166 certified pairings with 34 indoor models: heat at 5°F 17,100 Btu/h with 5TXCD010AS3+TSTAT to 17,800 Btu/h with 5PX*CD07AS3+TSTAT; HSPF2 8.1 throughout; SEER2 15.2 with 5PX*B004AS3+TSTAT to 16.0 with 5PX*B006AS3+TSTAT. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

34 indoor units · 166 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. 5PX*B006AS3+TSTAT brand not stated 17,450 Btu/hat 5°F, full speed

    24 pairings, 12 with a furnace · 47°F 30,200 Btu/h · 95°F cooling 33,300 Btu/h · Cold output 58% · COP 2.37

  2. 5TXCB006AS3+TSTAT brand not stated 17,400 Btu/hat 5°F, full speed

    22 pairings, 11 with a furnace · 47°F 30,200 Btu/h · 95°F cooling 33,200 Btu/h · Cold output 58% · COP 2.37

  3. 5PX*BD06AS3+TSTAT brand not stated 17,600 Btu/hat 5°F, full speed

    18 pairings, 9 with a furnace · 47°F 31,000 Btu/h · 95°F cooling 33,800 Btu/h · Cold output 57% · COP 2.34

  4. 5PX*C009AS3+TSTAT brand not stated 17,500 Btu/hat 5°F, full speed

    10 pairings, 5 with a furnace · 47°F 30,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 58% · COP 2.38

  5. 5TXCC009AS3+TSTAT brand not stated 17,500 Btu/hat 5°F, full speed

    10 pairings, 5 with a furnace · 47°F 30,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 58% · COP 2.38

  6. 5PX*C007AS3+TSTAT brand not stated 17,650 Btu/hat 5°F, full speed

    8 pairings, 4 with a furnace · 47°F 30,400 Btu/h · 95°F cooling 33,900 Btu/h · Cold output 58% · COP 2.37

  7. 5PX*B004AS3+TSTAT brand not stated 17,500 Btu/hat 5°F, full speed

    6 pairings, 3 with a furnace · 47°F 29,800 Btu/h · 95°F cooling 32,400 Btu/h · Cold output 59% · COP 2.31

  8. 5TXCC007AS3+TSTAT brand not stated 17,700 Btu/hat 5°F, full speed

    6 pairings, 3 with a furnace · 47°F 30,400 Btu/h · 95°F cooling 33,800 Btu/h · Cold output 58% · COP 2.37

  9. 5PX*C005AS3+TSTAT (the pairing on screen) brand not stated 17,500 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 30,000 Btu/h · 95°F cooling 32,700 Btu/h · Cold output 58% · COP 2.33

  10. 5PX*CD07AS3+TSTAT brand not stated 17,750 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 31,200 Btu/h · 95°F cooling 33,900 Btu/h · Cold output 57% · COP 2.32

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
5PX*B006AS3+TSTAT — 17,450 30,200 33,300 58% 2.37 NC 24
5TXCB006AS3+TSTAT — 17,400 30,200 33,200 58% 2.37 NC 22
5PX*BD06AS3+TSTAT — 17,600 31,000 33,800 57% 2.34 NC 18
5PX*C009AS3+TSTAT — 17,500 30,000 34,200 58% 2.38 NC 10
5TXCC009AS3+TSTAT — 17,500 30,000 34,200 58% 2.38 NC 10
5PX*C007AS3+TSTAT — 17,650 30,400 33,900 58% 2.37 NC 8
5PX*B004AS3+TSTAT — 17,500 29,800 32,400 59% 2.31 NC 6
5TXCC007AS3+TSTAT — 17,700 30,400 33,800 58% 2.37 NC 6
5PX*C005AS3+TSTAT (the pairing on screen) — 17,500 30,000 32,700 58% 2.33 NC 4
5PX*CD07AS3+TSTAT — 17,750 31,200 33,900 57% 2.32 NC 4

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 34 indoor units All 166 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

History and definitions

Other Bronze 15 models by nominal cooling size: N5HP5018A1 (18,000 Btu), N5HP5024A1 (24,000 Btu), N5HP5030A1 (30,000 Btu), N5HP5042A1 (42,000 Btu), N5HP5048A1 (42,000 Btu), N5HP5060A1 (54,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Jun 29, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “N5HP5036A1 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/n5hp5036a1