LHT060H4E*1P
Allied Commercial and Lennox · central heat pump
All 14 certified Allied Commercial models · All 152 certified Lennox models
LHT060H4E*1P is in the certified data as of Sep 19, 2026. LHT060H4E*1P returned to the certified data between August 2025 and September 2026.
- 54,000 Btu (4.5-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
55,00016.12NR
No 47°F rating for this pairing.
30,0008.79NR at 17°F
42,00012.31NR at 5°F
Btu/hkW, certified
2.22NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 55,000 Btu/h16.12 kW of heat at 47°F, 30,000 Btu/h8.79 kW at 17°F, and 42,000 Btu/h12.31 kW at 5°F, 76% of its 47°F rating. It delivers 55,000 Btu/h16.12 kW of cooling at 95°F. At 5°F that is 2,000 Btu/h0.59 kW above the example heating load of 40,000 Btu/h11.72 kW; at 95°F it is 35,000 Btu/h10.26 kW above the example cooling load of 20,000 Btu/h5.86 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h11.72 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h5.86 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 211198014 · listed by Lennox · certified Apr 22, 2026 · 2 pairings on 2 certificates share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 42,00012.31 kW | +5% | 2.22 | |
| 17°Ffull speed | 30,0008.79 kW | −21% | NR | |
| 47°Fhigh stage | 55,00016.12 kW | −2% | NR | |
| 95°Fcooling, full load | 55,00016.12 kW | — | NR |
EER2 11.4 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.54kW
- Electrical input in the 95°F cooling test
- 4.82kW
- Seasonal average heating COP
- 2.11
These exclude backup resistance heat.
How it compares with other 54,000 Btu heat pumps
4.5-ton central models
- This pairing at 5°F
- 42,000 Btu/h12.31 kWNR
- This unit at 5°F median across its pairings
- 42,000 Btu/h12.31 kW
- Median of 4.5-ton central models at 5°F
- 40,000 Btu/h11.72 kW
- Models in this group
- 343
This unit is above 59% of them, at number 140 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.
Among 54,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 117th of 343 (tied); HSPF2, 348th of 358 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- WLP14AY60AJ2N: The same 55,000 Btu/h rating at 47°F; 25,800 Btu/h at 5°F (this model: 42,000).
- WLP15AY60AJ2N: The same 55,000 Btu/h rating at 47°F; 27,600 Btu/h at 5°F (this model: 42,000).
- MOVA-61HN10-M152L: The same 55,000 Btu/h rating at 47°F; 28,000 Btu/h at 5°F (this model: 42,000).
Closest models by heat at 5°F
- SHV60H2BAInnovair · 43,000 Btu/h
- FP10983USCostway · 42,500 Btu/h
- AUWR-6024PHisense · 42,000 Btu/h
- MSD-60HD-BMulti MFG · 42,000 Btu/h
- SL22KLV-060-230ALennox · 42,000 Btu/h
- CU-HM55BAHUPanasonic · 41,000 Btu/h
Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 42,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 1,000–1,750 |
| Mild | Typical | 16–26 | 1,620–2,630 |
| Mild | Tight, well insulated | 10–18 | 2,330–4,200 |
| Cold | Drafty, little insulation | 28–52 | 810–1,500 |
| Cold | Typical | 18–30 | 1,400–2,330 |
| Cold | Tight, well insulated | 12–22 | 1,910–3,500 |
| Very cold | Drafty, little insulation | 32–58 | 720–1,310 |
| Very cold | Typical | 22–38 | 1,110–1,910 |
| Very cold | Tight, well insulated | 16–28 | 1,500–2,630 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for LHT060H4E*1P
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 55,000 Btu/h16.12 kWNR | 55,000 Btu/h16.12 kW |
| Heat output at 17°F full speed | 30,000 Btu/h8.79 kWNR | 30,000 Btu/h8.79 kW |
| Heat output at 5°F full speed | 42,000 Btu/h12.31 kWNR | 42,000 Btu/h12.31 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 76%NR | |
| COP at 5°F full speed | 2.22NR | 2.22 |
| HSPF2 Region IV | 7.2NR | 7.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 55,000 Btu/h16.12 kWNR | 55,000 Btu/h16.12 kW |
| EER2 at 95°F | 11.4NR | 11.4 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | LHT060H4E*1P | |
Pairings, by indoor-unit class
2 certified pairings
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 42,000 Btu/h12.31 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 42,00012.31 | 55,00016.12 | 55,00016.12 | 76% | 2.22 | NC | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- LHT060H4E*1P 2 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- LHT060H4E*1P returned to the certified data between August 2025 and September 2026.
- LHT060H4E*1P was last in the certified data in records from March 2025; it was not in the list on May 20, 2025.
- LHT060H4E*1P was in the certified data by September 2024.
History and definitions
Other E-SERIES models by nominal cooling size: LDT024H4E*1P (24,000 Btu), LDT036H4E*1P (36,000 Btu), LDT036H5E*1P (36,000 Btu), LDT048H4E*1P (42,000 Btu), LDT048H5E*1P (42,000 Btu), LDT060H4E*1P (54,000 Btu), LDT060H5E*1P (54,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 22, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read