Heat Pump List

Tools

MOVA-60HDN1-M16G

MOVA-60HDN1-M16G is in the certified data.

Its certified full-speed heating output at 5°F is 24,000–30,200 Btu/h, 63–70% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Midea · central heat pump

All 359 certified Midea models

MOVA-60HDN1-M16G is in the certified data as of Sep 19, 2026.

2 certified pairings with 2 different figures. See all

Certified heating and cooling

Heating at 47°F

34,200

25,000 at 17°F

24,000 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

34,200

Btu/h, certified

EER2 10.4 at 95°F

SEER2 16.3

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MOVA-60HDN1-M16G, by outdoor temperature Heating: 24,000 Btu/h at 5°F, 25,000 Btu/h at 17°F, 34,200 Btu/h at 47°F. Cooling: 34,200 Btu/h at 95°F. The bars start at zero. Median of 3-ton central models: 26,400 Btu/h at 5°F, 26,200 Btu/h at 17°F, 35,200 Btu/h at 47°F, 35,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 50,000 Btu/h 24,000 5°F 25,000 17°F 34,200 47°F 34,200 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 34,200 Btu/h of heat at 47°F, 25,000 Btu/h at 17°F, and 24,000 Btu/h at 5°F, 70% of its 47°F rating. It delivers 34,200 Btu/h of cooling at 95°F. At 5°F that is 2,500 Btu/h short of the example heating load of 26,500 Btu/h; at 95°F it is 21,200 Btu/h above the example cooling load of 13,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 208128205 · listed by Midea · certified Jun 9, 2026 · 1 pairing carries these values

Rebates where you live

Meets the recorded equipment thresholds of 37 programs in 25 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (1), New Jersey (3), New York (4), North Carolina (1), Oregon (2), Pennsylvania (1), South Carolina (1), Tennessee (1), Texas (2), Utah (1), Vermont (3), Washington (2), Wisconsin (1).

All 37 programs by state and province

Alabama

Arizona

California

Idaho

Illinois

Kansas

Kentucky

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 24,0007.03 kW −9% 2.00
17°Ffull speed 25,0007.33 kW −5% NR
47°Fnormal speed 34,20010.02 kW −3% NR
95°Fcooling, full load 34,20010.02 kW — NR

EER2 10.4 in that test. SEER2 16.3 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.52kW
Electrical input in the 95°F cooling test
3.29kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton central models

This pairing at 5°F
24,000 Btu/h
This unit at 5°F median across its pairings
24,000 Btu/h
Median of 3-ton central models at 5°F
26,400 Btu/h
Models in this group
451

This unit is above 35% of them, at number 291 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 36,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 294th of 451 (tied); HSPF2, 222nd of 467 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • (C,H,T)4H5S36*K*AAA*: The same 34,200 Btu/h rating at 47°F; 10,000 Btu/h at 5°F (this model: 24,000).
  • RHPXYC036AJT: The same 34,200 Btu/h rating at 47°F; 13,800 Btu/h at 5°F (this model: 24,000).
  • C4H5S36*K*AAA*: The same 34,200 Btu/h rating at 47°F; 15,800 Btu/h at 5°F (this model: 24,000).

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 24,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42570–1,000
MildTypical16–26920–1,500
MildTight, well insulated10–181,330–2,400
ColdDrafty, little insulation28–52460–860
ColdTypical18–30800–1,330
ColdTight, well insulated12–221,090–2,000
Very coldDrafty, little insulation32–58410–750
Very coldTypical22–38630–1,090
Very coldTight, well insulated16–28860–1,500

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for MOVA-60HDN1-M16G

2 pairings · 2 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MOVA-60HDN1-M16G
This pairingAll pairings
Heating
Heat output at 47°F normal speed 34,200 Btu/h 34,200–48,000 Btu/h
Heat output at 17°F full speed 25,000 Btu/h 25,000–38,000 Btu/h
Heat output at 5°F full speed 24,000 Btu/h 24,000–30,200 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 70%
COP at 5°F full speed 2.00 1.87–2.00
HSPF2 Region IV 8.5 8.5
Cooling
Cooling capacity at 95°F full-load test 34,200 Btu/h 34,200–48,000 Btu/h
EER2 at 95°F 10.4 10.4–12.0
SEER2 cooling season 16.3 16.1–16.3
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit MVME36B2MN1TA 2 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On some pairings
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold United States United States
Model string as certified MOVA-60HDN1-M16G

Across 2 certified pairings with 2 indoor models: heat at 5°F 24,000 Btu/h with MVME36B2MN1TA to 30,200 Btu/h with MVME48C2MN1TA; HSPF2 8.5 throughout; SEER2 16.1 with MVME48C2MN1TA to 16.3 with MVME36B2MN1TA. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

2 indoor units · 2 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 2 indoor units

  1. MVME36B2MN1TA (the pairing on screen) brand not stated 24,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 34,200 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 70% · COP 2.00

  2. MVME48C2MN1TA brand not stated 30,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 48,000 Btu/h · 95°F cooling 48,000 Btu/h · Cold output 63% · COP 1.87

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MVME36B2MN1TA (the pairing on screen) — 24,000 34,200 34,200 70% 2.00 Yes 1
MVME48C2MN1TA — 30,200 48,000 48,000 63% 1.87 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Other model numbers with identical certified values

2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

History and definitions

Other XD16H models by nominal cooling size: MOVA-24HDN1-M16G (18,000 Btu), MOVA-36HDN1-M16G (24,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Jun 9, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “MOVA-60HDN1-M16G — certified heat output”. Certified figures dated , checked daily.