RP15AY48AJ2N
Rheem and Ruud · central heat pump
All 91 certified Rheem models · All 89 certified Ruud models
RP15AY48AJ2N is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
45,50013.33NR
No 47°F rating for this pairing.
29,6008.67NR at 17°F
23,0006.74NR at 5°F
Btu/hkW, certified
2.20NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 45,500 Btu/h13.33 kW of heat at 47°F, 29,600 Btu/h8.67 kW at 17°F, and 23,000 Btu/h6.74 kW at 5°F, 51% of its 47°F rating. It delivers 45,500 Btu/h13.33 kW of cooling at 95°F. At 5°F that is 13,500 Btu/h3.96 kW short of the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 27,500 Btu/h8.06 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216581274 · listed by Rheem · certified Apr 9, 2025 · 2 pairings share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 23,0006.74 kW | −37% | 2.20 | |
| 17°Fone compressor speed | 29,6008.67 kW | −15% | NR | |
| 47°Fone compressor speed | 45,50013.33 kW | −5% | NR | |
| 95°Fcooling, full load | 45,50013.33 kW | — | NR |
EER2 11.7 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.06kW
- Electrical input in the 95°F cooling test
- 3.89kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 23,000 Btu/h6.74 kWNR
- This unit at 5°F median across its pairings
- 23,000 Btu/h6.74 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 7% of them, at number 378 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Among 48,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 348th of 408 (tied); HSPF2, 297th of 420 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- FOP1948MJAYCA: The same 45,500 Btu/h rating at 47°F; 42,000 Btu/h at 5°F (this model: 23,000).
- 5TWV8X48A1: The same 45,500 Btu/h rating at 47°F; 35,000 Btu/h at 5°F (this model: 23,000).
- RHPXYC048AJT: The same 45,500 Btu/h rating at 47°F; 18,000 Btu/h at 5°F (this model: 23,000).
Closest models by heat at 5°F
- FRP15AY48AJ2NFriedrich · 23,400 Btu/h
- MLP15AY48AJ2NMainline · 23,400 Btu/h
- 4SHP22LX148P-**AAirEase and Armstrong Air · 23,200 Btu/h
- ML16KP2-048-230ALennox · 22,600 Btu/h
- 5DCZ5048A1American Standard and Trane · 22,000 Btu/h
- 5WCZ5048A1American Standard and Trane · 22,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 23,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 550–960 |
| Mild | Typical | 16–26 | 880–1,440 |
| Mild | Tight, well insulated | 10–18 | 1,280–2,300 |
| Cold | Drafty, little insulation | 28–52 | 440–820 |
| Cold | Typical | 18–30 | 770–1,280 |
| Cold | Tight, well insulated | 12–22 | 1,050–1,920 |
| Very cold | Drafty, little insulation | 32–58 | 400–720 |
| Very cold | Typical | 22–38 | 610–1,050 |
| Very cold | Tight, well insulated | 16–28 | 820–1,440 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for RP15AY48AJ2N
6 pairings · 6 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 45,500 Btu/h13.33 kWNR | 45,500 Btu/h13.33 kW |
| Heat output at 17°F full speed | 29,600 Btu/h8.67 kWNR | 29,600–30,000 Btu/h8.67–8.79 kW |
| Heat output at 5°F full speed | 23,000 Btu/h6.74 kWNR | 23,000–23,400 Btu/h6.74–6.86 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 51%NR | |
| COP at 5°F full speed | 2.20NR | 2.20 |
| HSPF2 Region IV | 8.1NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 45,500 Btu/h13.33 kWNR | 45,500 Btu/h13.33 kW |
| EER2 at 95°F | 11.7NR | 11.7 |
| SEER2 cooling season | 15.2NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | RH2TY4824STANN | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | RP15AY48AJ2N | |
Across 6 certified pairings with 3 indoor models: heat at 5°F 23,000 Btu/h with RH2TY4824STANN to 23,400 Btu/h with RH2VY4824STACN; HSPF2 7.8 with RH2TY4821STANN to 8.1 with RH2TY4824STANN; SEER2 15.2 with RH2TY4821STANN to 16.0 with RH2VY4824STACN. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
3 indoor units · 6 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 3 indoor units
-
RH2TY4821STANN (the pairing on screen) brand not stated NRat 5°F, full speed
-
RH2TY4824STANN (the pairing on screen) brand not stated 23,000 Btu/h6.74 kWat 5°F, full speed
-
RH2VY4824STACN (the pairing on screen) brand not stated 23,400 Btu/h6.86 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| RH2TY4821STANN (the pairing on screen) | — | NR | 45,50013.33 | 45,50013.33 | NR | — | NC | 2 |
| RH2TY4824STANN (the pairing on screen) | — | 23,0006.74 | 45,50013.33 | 45,50013.33 | 51% | 2.20 | Yes | 2 |
| RH2VY4824STACN (the pairing on screen) | — | 23,4006.86 | 45,50013.33 | 45,50013.33 | 51% | 2.20 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- RP15AY48AJ2N 6 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other CLASSIC PLUS models by nominal cooling size: RP15AY18AJ2N (18,000 Btu), RP15AZ18AJ2N (18,000 Btu), WP15AZ18AJ2N (18,000 Btu), RD16AY24AJVC (24,000 Btu), RP15AZ24AJ2N (24,000 Btu), WP15AZ24AJ2N (24,000 Btu), RD16AY36AJVC (30,000 Btu), RP15AZ30AJ2N (30,000 Btu); more models from this brand.
Other Classic Plus models by nominal cooling size: RO2HFZ18AJ1H (18,000 Btu), RP15AZ18AJ2N (18,000 Btu), RD16AY24AJVC (24,000 Btu), RO3HFZ24AJ1H (24,000 Btu), RP15AZ24AJ2N (24,000 Btu), RP17AY24AJVC (24,000 Btu), RP15AZ30AJ2N (30,000 Btu), RP15AZ36AJ2N (36,000 Btu); more models from this brand.
Other CLASSIC SERIES models by nominal cooling size: RP15AY18AJ2N (18,000 Btu), RP15AZ18AJ2N (18,000 Btu), RP15AZ24AJ2N (24,000 Btu), RP15AZ30AJ2N (30,000 Btu), RP14AZ36AJ2N (36,000 Btu), RP15AZ36AJ2N (36,000 Btu), RP14AY48AJ2N (48,000 Btu), RP14AY60AJ2N (54,000 Btu); more models from this brand.
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 9, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read