Heat Pump List

Tools

Are ACiQ and Kenmore heat pumps the same?

32 model numbers are listed under both ACiQ and Kenmore. For 21 of them the certified record is the same record under each brand.

  • 32 shared model numbers
  • 21 identical records
  • 11 records that differ
  • Updated Oct 26, 2026

How much of each range overlaps

Each brand's range, and how much of it is shared with the other
Brand Units in the certified data Certified combinations Share of its range that is shared
ACiQ 133 7,847 24.1%
Kenmore 179 10,656 17.9%

“Share of its range” is shared model numbers divided by that brand's own units. The two shares differ because the two ranges are different sizes. One row per unit (a certified model number), not per brand entry.

The model numbers they share

32 of 32 shown

Model numbers listed under both brands. The 5°F figure is the median across that unit's own certified pairings.

Model numbers listed under both ACiQ and Kenmore
Model number Size class TypeHeat at 5°FBtu/hkW COP at 5°F Pairings ACiQ Kenmore Same record Cold climate
B5H3V60*K*AAA* 54,000 Btu (4.5-ton) central 46,000 2.00 306 34 34 Identical Yes
B5H0V60*K*AAA* 54,000 Btu (4.5-ton) central 44,500 2.08 950 139 139 Differs Yes
B5H3V48*K*AAA* 42,000 Btu (3.5-ton) central 36,600 1.88 648 72 72 Identical Yes
B5H0V48*K*AAA* 48,000 Btu (4-ton) central 36,400 2.02 2,961 336 336 Identical Yes
N5H8T60*K*AAA* 54,000 Btu (4.5-ton) central 30,200 2.25 1,164 118 121 Differs NC
N5H5S60*K*AAA* 54,000 Btu (4.5-ton) central 28,600 2.18 11 1 1 Identical NC
R5H5S60*K*AAA* 54,000 Btu (4.5-ton) central 28,600 2.18 11 1 1 Identical NC
B5H3V36*K*AAA* 36,000 Btu (3-ton) central 28,000 2.04 4,626 514 514 Identical Yes
B5H0V36*K*AAA* 36,000 Btu (3-ton) central 25,200 1.88 2,465 270 270 Differs Yes
N5H8T48*K*AAA* 48,000 Btu (4-ton) central 25,000 2.15 3,888 391 405 Identical NC
N5H5S48*K*AAA* 48,000 Btu (4-ton) central 24,400 2.28 53 3 5 Differs NC
R5H5S48*K*AAA* 48,000 Btu (4-ton) central 24,400 2.28 53 3 5 Differs NC
B5H3V24*K*AAA* 24,000 Btu (2-ton) central 22,200 1.98 3,771 419 419 Identical Yes
PHR560000K***K1 54,000 Btu (4.5-ton) central 22,200 2.00 11 1 1 Identical NC
N5H5S42*K*AAA* 42,000 Btu (3.5-ton) central 19,900 2.26 43 3 4 Identical NC
R5H5S42*K*AAA* 42,000 Btu (3.5-ton) central 19,900 2.26 43 3 4 Identical NC
N5H8T36*K*AAA* 36,000 Btu (3-ton) central 19,000 2.24 2,442 251 254 Identical NC
PHR548000K***K1 48,000 Btu (4-ton) central 18,200 1.95 11 1 1 Identical NC
N5H5S36*K*AAA* 36,000 Btu (3-ton) central 17,500 2.18 312 26 29 Differs NC
R5H5S36*K*AAA* 36,000 Btu (3-ton) central 17,500 2.18 312 26 29 Differs NC
B5H0V24*K*AAA* 24,000 Btu (2-ton) central 16,400 1.94 284 86 86 Identical Yes
R5H5S31*K*AAA* 30,000 Btu (2.5-ton) central 14,000 2.06 382 4 39 Differs NC
N5H5S30*K*AAA* 30,000 Btu (2.5-ton) central 13,500 2.10 64 5 6 Differs NC
R5H5S30*K*AAA* 30,000 Btu (2.5-ton) central 13,500 2.10 64 5 6 Differs NC
PHR536000K***K1 36,000 Btu (3-ton) central 12,700 1.77 11 1 1 Identical NC
N5H5S24*K*AAA* 24,000 Btu (2-ton) central 11,400 2.10 1,985 182 187 Identical NC
R5H5S24*K*AAA* 24,000 Btu (2-ton) central 11,400 2.10 1,988 182 187 Identical NC
N5H8T24*K*AAA* 24,000 Btu (2-ton) central 11,100 2.06 4,839 463 512 Identical NC
PHR524000K***K1 24,000 Btu (2-ton) central 8,600 1.90 11 1 1 Identical NC
N5H5S18*K*AAA* 18,000 Btu (1.5-ton) central 8,400 2.04 505 45 47 Identical NC
R5H5S18*K*AAA* 18,000 Btu (1.5-ton) central 8,400 2.04 505 45 47 Identical NC
R5H5S19*K*AAA* 18,000 Btu (1.5-ton) central 8,400 2.00 749 4 77 Differs NC

NC not cold-climate certified — not in the certified data

32 of 32 shared model numbers All brand pairs

Updated Oct 26, 2026 · Methodology