DZ6VSA361EA
DZ6VSA361EA is in the certified data.
Its certified full-speed heating output at 5°F is 29,000–30,000 Btu/h8.50–8.79 kW, 85–88% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Daikin · central heat pump
DZ6VSA361EA is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
34,20010.02NR
No 47°F rating for this pairing.
23,0006.74NR at 17°F
29,0008.50NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 34,200 Btu/h10.02 kW of heat at 47°F, 23,000 Btu/h6.74 kW at 17°F, and 29,000 Btu/h8.50 kW at 5°F, 85% of its 47°F rating. It delivers 34,200 Btu/h10.02 kW of cooling at 95°F. At 5°F that is 2,500 Btu/h0.73 kW above the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 21,200 Btu/h6.21 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 212614919 · listed by Daikin · certified Apr 22, 2026 · 15 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 29,0008.50 kW | +10% | 2.00 | |
| 17°Ffull speed | 23,0006.74 kW | −12% | NR | |
| 47°Fnormal speed | 34,20010.02 kW | −3% | NR | |
| 95°Fcooling, full load | 34,20010.02 kW | — | NR |
EER2 10.0 in that test. SEER2 17.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.25kW
- Electrical input in the 95°F cooling test
- 3.42kW
- Seasonal average heating COP
- 2.52
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 29,000 Btu/h8.50 kWNR
- This unit at 5°F median across its pairings
- 29,000 Btu/h8.50 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 61% of them, at number 177 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- RD17AZ36AJ3NFriedrich, Rheem + 3 more · 29,400 Btu/h
- RP19AY36AJVCRheem · 29,400 Btu/h
- D5CURAH36AAKAirquest, Arcoaire + 15 more · 29,200 Btu/h
- MDPH18036DMRCOOL · 29,000 Btu/h
- 1U36T3PC*HEHaier · 28,400 Btu/h
- 7SCP18V36P-**AAllied, Concord + 1 more · 28,400 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for DZ6VSA361EA
29 pairings · 29 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 34,200 Btu/h10.02 kWNR | 34,200 Btu/h10.02 kW |
| Heat output at 17°F full speed | 23,000 Btu/h6.74 kWNR | 23,000 Btu/h6.74 kW |
| Heat output at 5°F full speed | 29,000 Btu/h8.50 kWNR | 29,000–30,000 Btu/h8.50–8.79 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 85%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 8.6NR | 8.6 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 34,200 Btu/h10.02 kWNR | 34,200 Btu/h10.02 kW |
| EER2 at 95°F | 10.0NR | 10.0 |
| SEER2 cooling season | 17.5NR | 17.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | CA*EA4830*4A*+MBVC1600**-1A* | 15 indoor units |
| Furnace | No furnace | 16 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | Canada | US and Canada |
| Model string as certified | DZ6VSA361EA* | |
Pairings, by indoor-unit class
15 indoor units · 29 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 2 indoor units
-
CA*EA4830*4A* (the pairing on screen) brand not stated 29,000 Btu/h8.50 kWat 5°F, full speed
-
CA*EA6030*4A* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CA*EA4830*4A* (the pairing on screen) | — | 29,0008.50 | 34,20010.02 | 34,20010.02 | 85% | 2.00 | Yes | 10 |
| CA*EA6030*4A* (the pairing on screen) | — | 30,0008.79 | 34,20010.02 | 34,20010.02 | 88% | 2.00 | Yes | 6 |
Air handler · 13 indoor units
-
CA*EA4830*4A*+MBVC1600**-1A* (the pairing on screen) brand not stated 29,000 Btu/h8.50 kWat 5°F, full speed
-
CA*EA4830*4A*+MBVK16CP1X00A* (the pairing on screen) brand not stated 29,000 Btu/h8.50 kWat 5°F, full speed
-
CA*EA6030*4A*+MBVC2000**-1A* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
-
CA*EA6030*4A*+MBVK20DP1X00A* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
-
DFVE42CP0400A* (the pairing on screen) brand not stated 29,000 Btu/h8.50 kWat 5°F, full speed
-
DFVE42CP1400A* (the pairing on screen) brand not stated 29,000 Btu/h8.50 kWat 5°F, full speed
-
DFVE42CP1400B* (the pairing on screen) brand not stated 29,000 Btu/h8.50 kWat 5°F, full speed
-
DFVE48DP0400A* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
-
DFVE48DP1400A* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
-
DFVE48DP1400B* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
-
DFVE60DP0400A* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
-
DFVE60DP1400A* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
-
DFVE60DP1400B* (the pairing on screen) brand not stated 30,000 Btu/h8.79 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CA*EA4830*4A*+MBVC1600**-1A* (the pairing on screen) | — | 29,0008.50 | 34,20010.02 | 34,20010.02 | 85% | 2.00 | Yes | 1 |
| CA*EA4830*4A*+MBVK16CP1X00A* (the pairing on screen) | — | 29,0008.50 | 34,20010.02 | 34,20010.02 | 85% | 2.00 | Yes | 1 |
| CA*EA6030*4A*+MBVC2000**-1A* (the pairing on screen) | — | 30,0008.79 | 34,20010.02 | 34,20010.02 | 88% | 2.00 | Yes | 1 |
| CA*EA6030*4A*+MBVK20DP1X00A* (the pairing on screen) | — | 30,0008.79 | 34,20010.02 | 34,20010.02 | 88% | 2.00 | Yes | 1 |
| DFVE42CP0400A* (the pairing on screen) | — | 29,0008.50 | 34,20010.02 | 34,20010.02 | 85% | 2.00 | Yes | 1 |
| DFVE42CP1400A* (the pairing on screen) | — | 29,0008.50 | 34,20010.02 | 34,20010.02 | 85% | 2.00 | Yes | 1 |
| DFVE42CP1400B* (the pairing on screen) | — | 29,0008.50 | 34,20010.02 | 34,20010.02 | 85% | 2.00 | Yes | 1 |
| DFVE48DP0400A* (the pairing on screen) | — | 30,0008.79 | 34,20010.02 | 34,20010.02 | 88% | 2.00 | Yes | 1 |
| DFVE48DP1400A* (the pairing on screen) | — | 30,0008.79 | 34,20010.02 | 34,20010.02 | 88% | 2.00 | Yes | 1 |
| DFVE48DP1400B* (the pairing on screen) | — | 30,0008.79 | 34,20010.02 | 34,20010.02 | 88% | 2.00 | Yes | 1 |
| DFVE60DP0400A* (the pairing on screen) | — | 30,0008.79 | 34,20010.02 | 34,20010.02 | 88% | 2.00 | Yes | 1 |
| DFVE60DP1400A* (the pairing on screen) | — | 30,0008.79 | 34,20010.02 | 34,20010.02 | 88% | 2.00 | Yes | 1 |
| DFVE60DP1400B* (the pairing on screen) | — | 30,0008.79 | 34,20010.02 | 34,20010.02 | 88% | 2.00 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 22, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read